Search results for "Cathode"
showing 10 items of 296 documents
The response behaviour of LiF:Mg,Cu,P thermoluminescence dosimeters to high-energy electron beams used in radiotherapy
1995
To ensure the effectiveness of radiation-therapy treatments, both in-phantom and in-patient reliable dose measurements are required. Thermoluminescence dosimeters are used commonly for both applications. Among the various available materials, the relatively new LiF:Mg,Cu,P phosphor is a suitable candidate for quality control of in vivo dosimetry in electron-beam therapy. The response behaviour of LiF:Mg,Cu,P chips to 6-21 MeV electron beams used in radiotherapy was studied. Batch homogeneity, dose linearity, sensitivity change after use, dose and dose-rate response, energy dependence and fading characteristics were investigated. The contribution from each factor to the overall uncertainty i…
Fast k-Space Mapping of Electronic Bands Using Time-of-Flight Based Cathode-Lens Microspectroscopy.
2015
Investigation of diffusion and electromigration of hydrogen in palladium and PdAg alloy
1999
Abstract Diffusion and electromigration of hydrogen in PdH 0.1 , Pd 77 Ag 23 H 0.1 and Pd 50 Ag 50 H 0.1 alloy were measured by means of resistivity method. It is known that hydrogen migrates towards the cathode within the temperature range of 300–473 K in the PdH 0.1 and Pd 77 Ag 23 H 0.1 system. In Pd 50 Ag 50 H 0.1 , hydrogen migrates towards the cathode below 400 K, but towards the anode at higher temperatures. Its effective valency increases together with temperature. At the same time it satisfies the linear dependence on inverse specific resistance ρ : Z eff = Z i +( k / ρ ). The constants Z i and k have the following values: (1.05±0.01) and −(3.81±0.04)×10 −8 Ω m for hydrogen in PdH …
Novel Configuration for a C-Band Axial Vircator With High Output Power
2022
We present a novel configuration for an axial virtual cathode oscillator (Vircator) operating in the C-band and designed for high output power applications. In order to enhance the efficiency, we have employed a geometry with up to seven reflectors along the drift space. While in previous research works this optimization process has been performed only varying the reflectors radii while using a fixed distance between reflectors,in our work we propose an optimization in terms of both reflectors radii and distances. Our optimized structure for the axial Vircator is able to provide an efficiency up to 15.6% and an output power of 1.6 GW in the C-band, with a working voltage of 510 kV and a cat…
Different Space Charge Behavior of Materials Used in AC and DC Systems
2017
The aim of the present work is to evaluate the behavior, from the space charge accumulation phenomenon point of view, of three different XLPE specimens used as insulation materials in high voltage systems. Considering that under DC stress the charge accumulation is more relevant as compared to the AC case, in the specimens for DC applications additives are typically added. In this work, three different specimens are analyzed. One is a free additive sample used conventionally under AC stress and two others include different additives that are used under DC stress. In order to measure the space charge accumulation, the Pulsed Electro Acoustic (PEA) method has been employed. For each sample, t…
X-ray Absorption under Operating Conditions for Solid-Oxide Fuel Cells Electrocatalysts: The Case of LSCF/YSZ
2019
We describe a novel electrochemical cell for X-ray absorption spectroscopy (XAS) experiments during electrical polarization suitable for high-temperature materials such as those used in solid oxide fuel cells. A half-cell LSCF/YSZ was then investigated under cathodic and anodic conditions (850 °
The polarization dependence of x‐ray photoelectron yield of a Au photocathode
1994
We report a measurement of the total photoelectron yield of gold as a function of the incident x‐ray polarization. Polarized x rays with energies of 2.5, 2.7, and 4.0 keV were used to excite a gold photocathode at a glancing incidence angle between 5° and 50°. Contrary to a previous report, we found no measurable polarization dependence for all three x‐ray energies. We conclude that the modulation factor, i.e., the fractional change of the total yield when the polarization state is varied, is less than 4%.
Enhanced flexibility and electron-beam-controlled shape recovery in alumina-coated Au and Ag core–shell nanowires
2017
The proper choice of coating materials and methods in core–shell nanowire (NW) engineering is crucial to assuring improved characteristics or even new functionalities of the resulting composite structures. In this paper, we have reported electron-beam-induced reversible elastic-to-plastic transition in Ag/Al2O3 and Au/Al2O3 NWs prepared by the coating of Ag and Au NWs with Al2O3 by low-temperature atomic layer deposition. The observed phenomenon enabled freezing the bent core–shell NW at any arbitrary curvature below the yield strength of the materials and later restoring its initially straight profile by irradiating the NW with electrons. In addition, we demonstrated that the coating effic…
<title>Advanced light sources for atomic absorption analysis</title>
2003
High-frequency electrodeless light sources (HF EDLS) are widely used as bright radiators of narrow and intensive atomic and ionic spectral lines, covering the spectrum from VUV to IR. Main characteristics of HF EDLS are high emitted spectral line intensity, long service life, and in general, narrow spectral line shapes because of low-pressure of filling elements. In this work we give a short overview of the use of HF EDLS, containing Hg, Te, Se, Zn, Pb, As, Sb, Bi, Tl, In, Cd, Sn, in Zeeman Atomic absorption devices for assaying natural, drinking, waste and technical water as well as air, soil, food products and biological samples. The first steps are made for optimization of Ge, Ga, P, S, …
Spectroscopic response and charge transport properties of CdZnTe detectors grown by the vertical Bridgman technique
2015
In this work, we present the results of spectroscopic investigations on CdZnTe (CZT) detectors grown by the boron oxide encapsulated vertical Bridgman technique (1MEM-CNR, Parma, Italy). The detectors, with different thicknesses (1 and 2.5 mm), are characterized by the same electrode layout (gold electroless contacts): the anode is a central electrode (2 x 2 mm(2)) surrounded by a guard-ring electrode, while the cathode is a planar electrode covering the detector surface (4.1 x 4.1 mm(2)). The results of electrical investigations point out the low leakage currents of these detectors even at high bias voltages: 38 nA/cm(2) (T = 25 degrees C) at 10000 V/cm. The time stability and the spectros…