Search results for "Ceph"
showing 10 items of 2036 documents
An approach to single trial analysis of event-related potentials based on signal detection theory.
1996
Abstract The aim of the present paper was to introduce a single trial analysis to event-related potential measurement in order to illuminate the mechanisms behind an impaired P300 amplitude occurring under certain experimental conditions. For this purpose we applied tools from linear system theory and signal detection theory to single trials in an oddball paradigm in order to estimate the amplitude of the positive deflection around the P300 latency following target and nontarget stimuli. According to the density functions of these amplitude distributions we operationally defined ‘P300 absent in target’ (P300 amplitude smaller than an individual threshold under target conditions) as well as …
LOW-RANK APPROXIMATION BASED NON-NEGATIVE MULTI-WAY ARRAY DECOMPOSITION ON EVENT-RELATED POTENTIALS
2014
Non-negative tensor factorization (NTF) has been successfully applied to analyze event-related potentials (ERPs), and shown superiority in terms of capturing multi-domain features. However, the time-frequency representation of ERPs by higher-order tensors are usually large-scale, which prevents the popularity of most tensor factorization algorithms. To overcome this issue, we introduce a non-negative canonical polyadic decomposition (NCPD) based on low-rank approximation (LRA) and hierarchical alternating least square (HALS) techniques. We applied NCPD (LRAHALS and benchmark HALS) and CPD to extract multi-domain features of a visual ERP. The features and components extracted by LRAHALS NCP…
Multi-domain feature extraction for small event-related potentials through nonnegative multi-way array decomposition from low dense array EEG
2013
Non-negative Canonical Polyadic decomposition (NCPD) and non-negative Tucker decomposition (NTD) were compared for extracting the multi-domain feature of visual mismatch negativity (vMMN), a small event-related potential (ERP), for the cognitive research. Since signal-to-noise ratio in vMMN is low, NTD outperformed NCPD. Moreover, we proposed an approach to select the multi-domain feature of an ERP among all extracted features and discussed determination of numbers of extracted components in NCPD and NTD regarding the ERP context.
Exploring the switching of the focus of attention within working memory: A combined event-related potential and behavioral study.
2018
Abstract Working memory enables humans to maintain selected information for cognitive processes and ensures instant access to the memorized contents. Theories suggest that switching the focus of attention between items within working memory realizes the access. This is reflected in object-switching costs in response times when the item for the task processing is to be changed. Another correlate of attentional allocation in working memory is the P3a-component of the human event-related potential. The aim of this study was to demonstrate that switching of attention within working memory is a separable processing step. Participants completed a cued memory-updating task in which they were instr…
k-Nearest neighbour local linear prediction of scalp EEG activity during intermittent photic stimulation
2011
The characterization of the EEG response to photic stimulation (PS) is an important issue with significant clinical relevance. This study aims to quantify and map the complexity of the EEG during PS, where complexity is measured as the degree of unpredictability resulting from local linear prediction. EEG activity was recorded with eyes closed (EC) and eyes open (EO) during resting and PS at 5, 10, and 15. Hz in a group of 30 healthy subjects and in a case-report of a patient suffering from cerebral ischemia. The mean squared prediction error (MSPE) resulting from k-nearest neighbour local linear prediction was calculated in each condition as an index of EEG unpredictability. The linear or …
Reliability of Magnetoencephalography and High-Density Electroencephalography Resting-State Functional Connectivity Metrics
2019
Resting-state connectivity, for example, based on magnetoencephalography (MEG) or electroencephalography (EEG), is a widely used method for characterizing brain networks and a promising imaging biomarker. However, there is no established standard as to which method, modality, and analysis variant is preferable and there is only limited knowledge on the reproducibility, an important prerequisite for clinical application. We conducted an MEG-/ high-density (hd)-EEG-study on 22 young healthy adults, who were measured twice in a scan/rescan design after 7 – 2 days. Reliability of resting-state (15 min, eyes-closed) connectivity in source space was calculated via intraclass correlation coefficie…
Role of sensorimotor areas in early detection of motor errors: An EEG and TMS study
2019
Abstract Action execution is prone to errors and, while engaged in interaction, our brain is tuned to detect deviations from what one expects from other’s action. Prior research has shown that Event-Related-Potentials (ERPs) are specifically modulated by the observation of action mistakes interfering with goal achievement. However, in complex and modular actions, embedded motor errors do not necessarily produce an immediate effect on the global goal. Here we dissociate embedded motor goals from global action goals by asking subjects to observe familiar but untrained knotting actions. During knotting an embedded motor error (i.e. the rope is inserted top-down instead of bottom-up during the …
Study between anb angle and Wits appraisal in cone beam computed tomography (CBCT)
2013
Objectives: To analyse the ANB and Wits values and to study correlations between those two measurements and other measurements in diagnosing the anteroposterior maxilo-mandibular relationship with CBCT. Study Design: Ninety patients who had previously a CBCT (i-CAT®) as a diagnostic register were selected. A 3D cephalometry was designed using one software package, InVivo5®. This cephalometry included 3 planes of reference, 3 angle measurements and 1 linear measurement. The means and standard deviations of the mean of each measurement were assessed. After that, a Pearson´s correlation coefficient has been performed to analyse the significance of each relationship. Results: When classifying t…
Influence of skeletal class in the morphology of cervical vertebrae: A study using cone beam computed tomography
2016
ABSTRACT Objectives: To quantify the prevalence of cervical vertebrae anomalies and to analyze any association between them and skeletal malocclusions or head posture positions in the same study. Materials and Methods: Two hundred forty patients who were attending the Department of Orthodontics of the University of Valencia for orthodontic treatment were selected and divided into three groups: skeletal Class I (control group, 0° <ANB < 4°), Class II (ANB ≥ 4°), and Class III (ANB ≤ 0°) according to ANB Steiner angle. The morphology of the first five cervical vertebrae was analyzed with cone beam computed tomography to identify any anomalies. Intra- and interobserver error meth…
Auditory event-related potentials (ERP) reflect temporal changes in speech stimuli
1997
We studied the brain's reactions to deviations in the duration of a stop consonant using event-related potentials in an oddball paradigm. A naturally produced nonsense word was used as a frequent standard stimulus which differed from two infrequently presented deviant stimuli only by the duration of the silence period inside the stop, making the consonant sound longer. Evoked responses to the deviant stimuli showed sharply rising negativity after the unexpected prolongation of the silence and a later negativity, the duration of which was related to the timing of the beginning of the second part of the deviant sound. This later negativity is, at least partly, elicited by a mismatch process t…