Search results for "Certified reference materials"

showing 10 items of 43 documents

Mineral Profile of Children’s Fast Food Menu Samples

2017

Abstract Children’s fast food menus, including hamburgers served with french fries, dessert, and a soft drink, were analyzed to obtain the mineral profile of trace elements. The developed analytical methodology involved sample digestion under pressure inside a microwave oven with a mixture of HNO3 and H2O2 and inductively coupled plasma-optical emission spectrometry. The method was validated by carrying out the analysis of certified reference materials (NIST 1570a spinach leaves, NCS ZC73016 chicken, and NIST 1568a rice flour) and using recovery experiments. Repeatability was verified by analyzing replicate samples. Twenty-six elements were studied, 12 of which—aluminum, barium, calcium, co…

0301 basic medicineAdolescentMicrowave ovenchemistry.chemical_element01 natural sciencesAnalytical Chemistry03 medical and health sciencesLimit of DetectionHumansEnvironmental ChemistryFood scienceChildMicrowavesPharmacologyMineralsStrontium030109 nutrition & dieteticsChemistryMagnesiumFrench friesSpectrum Analysis010401 analytical chemistryBariumHydrogen PeroxideRepeatabilityFood AnalysisTrace Elements0104 chemical sciencesCertified reference materialsMetalsChild PreschoolCalibrationFast FoodsAgronomy and Crop ScienceFood AnalysisFood ScienceJournal of AOAC INTERNATIONAL
researchProduct

Determination of mercury at picogram level in natural waters with inductively coupled plasma mass spectrometry by using 3D printed metal scavengers

2019

The determination of ultra-trace concentrations of Hg in natural water samples via preconcentration using 3D printed metal scavenger technique followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed. The determination of Hg in certified reference material ERM-CA615 (groundwater) was performed with high accuracy and precision resulting in recovery of 100 ± 3% and RSD <2.5%, respectively. Selective laser sintering (SLS) 3D printing was used to fabricate the scavengers using a mixture of polyamide-12 powder with thiol-functionalized silica. The preconcentration procedure is based on the adsorption of Hg on the scavenger and followed by elution of the preconcentrated Hg …

3d printedmercuryelohopeavesichemistry.chemical_element02 engineering and technology01 natural sciencesBiochemistryAnalytical ChemistryMetalpreconcentration3D-tulostushaitalliset aineetEnvironmental Chemistryinductively coupled plasma mass spectrometryInductively coupled plasma mass spectrometrySpectroscopyvesistötNatural waterultra-trace concentration010401 analytical chemistry3D printing021001 nanoscience & nanotechnology0104 chemical sciencesMercury (element)spektrometriaCertified reference materialschemistryEnvironmental chemistryvisual_artvisual_art.visual_art_mediumnatural water0210 nano-technologyGroundwaterAnalytica Chimica Acta
researchProduct

A comparative study on sample preparation procedures for supplementary foods by ICP-OES: Green chemistry considerations

2015

An inductively coupled plasma optical emission (ICP-OES) method was developed for the simultaneous determination of major, minor and trace elements in food. Preliminary studies focused on selecting suitable operational conditions in order to provide the highest sensitivity and to maximize the number of analytes to be determined without spectral or matrix interference. Ruthenium and rhenium were evaluated as internal standards and samples were analyzed at different dilution levels. Furthermore, a comparative study was carried out by using three sample digestion methods, microwave-assisted digestion with HNO3/H2O2, dry ashing and dry ashing with Mg(NO3)2/MgO as an ashing aid. Adequate precisi…

Accuracy and precisionAnalyteChromatographyChemistryGeneral Chemical EngineeringGeneral EngineeringAnalytical chemistryAnalytical ChemistryDilutionCertified reference materialsAshingInductively coupled plasma atomic emission spectroscopySample preparationInductively coupled plasmaAnalytical Methods
researchProduct

Isotope dilution mass spectrometry as a calibration method for the analysis of trace elements in powder samples by LA-ICP-MS

2003

The applicability of the isotope dilution (ID) technique for trace element determinations in powdered solid samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is demonstrated. LA-ICP-IDMS combines the advantage of the isotope dilution technique as a definitive method with the powerful capability of LA-ICP-MS for a fast and direct multi-element analysis of solid samples. LA-ICP-IDMS therefore allows matrix-matched quantification of element concentrations without any external standard, which is not possible by other calibration strategies used in LA-ICP-MS, up to now. The sample preparation effort is kept minimal and consists of an addition of the corresponding…

AnalyteCertified reference materialsChromatographyIsotopeChemistrySample (material)Trace elementCalibrationAnalytical chemistrySample preparationIsotope dilutionSpectroscopyAnalytical ChemistryJ. Anal. At. Spectrom.
researchProduct

Analytical capabilities of high performance liquid chromatography – Atmospheric pressure photoionization – Orbitrap mass spectrometry (HPLC-APPI-Orbi…

2015

A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, …

AnalyteChromatographyAtmospheric pressureChemistryAnalytical chemistryRepeatabilityMass spectrometryOrbitrapBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrylaw.inventionPolybrominated diphenyl ethersCertified reference materialslawEnvironmental ChemistrySpectroscopyAnalytica Chimica Acta
researchProduct

Validated fast procedure for trace element determination in basil powder

2011

Abstract An inductively coupled plasma optical emission spectroscopic (ICP-OES) method has been developed and fully validated for trace element determination in basil samples. The method involves the previous sample digestion, under pressure, with a mixture of HNO 3 , HCl and H 2 O 2 inside a microwave oven, 42 elements were studied and 33 elements (Al, As, Ba, Ca, Cr, Co, Cu, Fe, Pb, Li, Mg, Mn, Mo, Ni, K, Se, Na, Sr, Tl, Ti, V, Zn, Sc, Y, La, Ce, Nd, Tb, Ho, Er, Tm, Yb, Lu) were determined quantitatively in basil leaves obtained from Morocco and Spain. The method provided recovery percentages from 89% to 113% for spiked concentrations at mg kg −1 and μg kg −1 . Accurate results were found…

Certified reference materialsChemistryInductively coupled plasma atomic emission spectroscopyMicrowave ovenAnalytical chemistryTrace elementGeneral MedicineOptical emission spectroscopyInductively coupled plasmaSpectroscopyChemical compositionFood ScienceAnalytical ChemistryFood Chemistry
researchProduct

Double Laser LIBS and micro-XRF spectroscopy applied to characterize materials coming from the Greek-Roman theater of Taormina

2009

The laser-induced breakdown spectroscopy (LIBS) is an applied physical technique that has shown, in recent years, its great potential for rapid qualitative analysis of materials. The possibility to implement a portable instrument that perform LIBS analysis makes this technique particularly useful for in situ analysis in the field of cultural heritages. The aim of this work is to compare the results, obtained by LIBS measurements with X-Ray Fluorescence (XRF) ones, on calcareous and refractory materials coming from the Greek-Roman theater of Taormina. Calibration curves for LIBS and XRF were obtained by measuring certified reference materials and using them as standards. LIBS measurements we…

ChemistryCalibration curvebusiness.industryX-ray fluorescenceLaserCollimated lightSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)law.inventionCertified reference materialsOpticslawCalibrationLIBS micro-XRF calcareous material refractory material cultural heritagesLaser-induced breakdown spectroscopySpectroscopybusiness
researchProduct

Development of standard operation procedures for the manufacture of n-octadecyl bonded silicas as packing material in certified reference columns for…

2004

The development of standard operation procedures for the manufacture of a n-octadecyl bonded spherical silica packing from partially condensed tetraethoxysilane as silica source is described. The synthesis comprises five intermediate products and six synthesis steps which were examined according to their reproducibility and robustness. The results led to the optimisation of the manufacturing process for a n-octadecyl bonded silica. Correlations were drawn between the dynamic viscosity of the poly(ethoxy)siloxane (PES), the synthesis parameters, the resulting pore structural properties and particle size distribution of the silicas. Validated procedures were developed to manufacture spherical…

ChromatographyChemistrySilicon dioxideOrganic ChemistryAnalytical chemistryReproducibility of ResultsGeneral MedicineReversed-phase chromatographyReference StandardsSilicon DioxideBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundCertified reference materialsSiloxaneSpecific surface areaParticle-size distributionPorosityChromatography LiquidJournal of chromatography. A
researchProduct

Hard cap espresso extraction-stir bar preconcentration of polychlorinated biphenyls in soil and sediments.

2017

Abstract A Nespresso © hard cap espresso machine has been employed for the quantitative extraction of polychlorinated biphenyls (PCBs) from sediments and soils. Sample extraction was performed from five grams of sample in less than 40 s, with 200 mL ethanol 40% (v/v) in water and PCBs were concentrated using stir bar sorptive extraction (SBSE) and determined by thermal desorption-gas chromatography-tandem mass spectrometry (TD-GC-MS-MS). Eleven PCB congeners (28, 52, 77, 80, 81, 101, 118, 138, 153,169, and 180) were determined in soils and sediments with limits of quantification in the 0.03–0.08 ng g −1 range. Extraction efficiency was established by the analysis of soil samples spiked with…

ChromatographySoil testChemistry010401 analytical chemistryExtraction (chemistry)010501 environmental sciencesMass spectrometry01 natural sciencesBiochemistryQuantitative determination0104 chemical sciencesAnalytical ChemistryEspressoCertified reference materialsEnvironmental chemistrySoil waterEnvironmental ChemistrySpectroscopy0105 earth and related environmental sciencesBar (unit)Analytica chimica acta
researchProduct

Progress in the standardisation of particle and surface characterisation

2002

In 1999, we published a comprehensive survey of standards and certified reference materials for dispersed and porous solids. The present paper summarises and reports on new standards and proposals.

Colloid and Surface ChemistryCertified reference materialsMaterials scienceStandardizationMetallurgyParticlePorous solidsColloids and Surfaces A: Physicochemical and Engineering Aspects
researchProduct