Search results for "Certified reference materials"
showing 10 items of 43 documents
Application of the slurry technique to biological materials: a survey of literature
1991
The literature on the application of the slurry technique to biological materials is reviewed. It is obvious from the various applications that the most frequently employed atomization method for slurry analysis in biological materials is electrothermal atomization using either graphite tube or platform atomizers. The slurry technique is particularly useful when certified reference materials are not available and when the standard addition method is to be avoided. The literature survey revealed that this technique compares favourably with other methods for the determination of trace metals in biological materials.
Systematic procedure for the preparation of sets of calibration standards for x-ray fluorescence analysis of ceramic materials
1998
A systematic procedure for the preparation of optimized sets of calibration solid standards for the x-ray fluorescence analysis of ceramic materials is described. The matrix of the contents of the N analytes in the n standards (n ≥ N) is calculated from an n x N experimental design matrix, and from the upper and lower limits of the calibration range for each of the N analytes. Two procedures, which are useful for taking into account analyte interactions, are proposed for constructing the experimental design matrix, i.e. the scroll procedure and the procedure of the centers. A program developed to help the analyst in designing and preparing the set of standards following the proposed procedu…
Fast determination of fish mineral profile. Application to Vietnamese panga fish
2013
A methodology, based on inductively coupled plasma optical emission spectrometry after microwave-assisted digestion with HNO3/H2O2, was developed to determine the mineral profile of panga fish samples imported from Vietnam. A total of 42 essential and toxic elements were studied in seven samples taken from the local market. Preliminary studies were focused on selecting the best wavelength and the required dilution of samples in order to provide the highest sensitivity to maximize the number of analytes to be determined without spectral or matrix interferences. Adequate accuracy was assured by the analysis of certified reference material TORT-2. Mercury was also determined by a direct method…
Total content of As, Sb, Se, Te and Bi in Spanish vegetables, cereals and pulses and estimation of the contribution of these foods to the Mediterrane…
2010
Abstract As, Sb, Se, Te and Bi were quantified in vegetables, pulses and cereals, in order to increase the available information on the presence of these elements in the Mediterranean daily intake. Samples were dry ashed and the ashes dissolved with diluted HCl. Hydride generation atomic fluorescence spectrometry was used for quantification. Limits of detection (LOD) ranged from 0.2 to 1.7 ng g−1 and the accuracy was assessed by the analysis of three certified reference materials, Rice Flour (NIST 1568a), Tomato Leaves (NIST 1573) and Cabbage (IAEA 359). Good concordance between results found and certified values were always observed. As, Sb, Se, Te and Bi levels varied in samples analysed …
Direct determination of total mercury in phosphate rock using alkaline fusion digestion
2014
The aim of this work was to develop a new method to determine the mercury (Hg) concentrations in phosphate rock using a dedicated analytical instrument (the DMA80 Tricell by Milestone) that employs an integrated sequence of thermal decomposition followed by catalyst conversion, amalgamation and atomic absorption spectrophotometry. However, this instrument underestimates Hg concentrations when phosphorite and apatite rocks are investigated with a classic thermal decomposition treatment that complies with US EPA method 7473. Therefore, to improve the recovery of total Hg, we performed alkaline fusion digestion (AFD) directly inside the furnace of the instrument, using BCR(32) as a certified r…
Iodine determination in food samples using inductively coupled plasma isotope dilution mass spectrometry.
1998
Two different sample treatment methods are used in connection with inductively coupled plasma isotope dilution mass spectrometry for accurate and precise determinations of iodine traces in food samples. 129I-enriched iodate is applied as a spike compound for the isotope dilution step. Extraction of iodine by tetramethylammonium hydroxide (TMAH) solution at high temperatures in a closed vessel is one of the sample treatment methods. The other one is a complete decomposition of the sample with a mixture of perchloric acid and nitric acid using microwave assistance. By analyzing different certified reference materials (three milk powders with different iodine levels, BCR CRM 63, 150, and 151; …
An interlaboratory study as useful tool for proficiency testing of chemical oxygen demand measurements using solid substrates and liquid samples with…
2009
In 2008, the first Proficiency Testing Scheme of Chemical Oxygen Demand (1stCOD-PTADG) was conducted to assess the results obtained for different research groups whose field work is mainly anaerobic digestion. This study was performed using four samples, two solid samples as raw materials and two solid samples to prepare high concentration suspended solid solutions. Invitations were sent to a large number of laboratories, mainly to anaerobic digestion research groups. Finally, thirty labs from sixteen countries agreed to participate, but for different reasons four participants could not send any data. In total, twenty-six results were reported to the COD-PT coordinator. This study showed th…
Goldschmidt Abstracts 2010 – F
2010
We report on two novel procedures for the determination of several trace elements in seawater, including elements characterized by very low abundance (sub-0.1 to 1 ng l-1) in the ocean, such as REEs, Hf, and Th. Our methods are based on the procedure developed recently by Bayon et al. [1], and applied successfully to a wide range of geological samples. It involves addition of a Tm spike and pre-concentration using co-precipitation, prior to analysis by inductively coupled plasma-sector field mass spectrometry (ICP-SFMS). The addition of a small amount of Tm to the sample produces a positive Tm anomaly in the resulting REE pattern, which allows calculation of precise trace element concentrat…
Food and Environment: Trace Element Content of Hen Eggs from Different Housing Types
2013
AbstractEleven trace elements (Ba, Cu, Fe, Mn, Ni, Pb, Rb, Se, Sr, V, Zn) were quantitatively determined in hen egg samples collected from different poultry housing types (large-scale poultry farms, organic farms and domestic farms) over the territory of Latvia. Samples were wet digested and quantitatively analysed by total reflection X-ray fluorescence spectrometry (TXRF). The accuracy of analytical method was verified with analysis of certified reference material NCS ZC73017 (GSB-10)-Apple. The most variable range of concentrations and the highest content of elements were determined for hen egg samples derived from organic farms, while egg samples from domestic farms and poultry farms mos…
The International Measurement Evaluation Programme (IMEP) IMEP-6: "Trace elements in water"
1998
The sixth round of the International Measurement Evaluation Programme (IMEP) is presented. The programme offers reference values, established by primary methods of measurement, against which participating laboratories can evaluate their performance. The degree of comparability is thus established against the most objective references available at present. In IMEP-6, reference values for total concentrations of 14 trace elements in a synthetic and a natural water were established mainly by isotope dilution mass spectrometry (IDMS). For the majority of the measurands, results traceable to the international system of units (SI) and having expanded uncertainties, U (k=2), of 2% could be establi…