Search results for "Cesium"

showing 10 items of 79 documents

Interaction of sodium, lithium, caesium, and potassium ions with ascorbyl radicals.

1987

Abstract The influence of the concentration of sodium, lithium , caesium, and potassium ions as well as of the ionic strength of the solutions used on the dismutation rate of ascorbyl radicals has been investigated. While the dismutation rate was not influenced by Li+, it decreased, however, with increasing concentrations of the other ions investigated. The largest effect was obtained with Na+. This change in dismutation rate indicates a stabilizing effect on ascorbyl radical by these ions.

Free RadicalsSodiumRadicalInorganic chemistryOsmolar ConcentrationSodiumchemistry.chemical_elementCesiumAscorbic AcidLithiumPotassium ionsAscorbic acidGeneral Biochemistry Genetics and Molecular BiologyIonchemistryIonic strengthCaesiumPotassiumAscorbate OxidaseLithiumZeitschrift fur Naturforschung. C, Journal of biosciences
researchProduct

Possible Ca 2+ -dependent mechanism of apical outer hair cell modulation within the cochlea of the guinea pig

1998

Calcium ions were precipitated with potassium antimonate after injection of the inorganic calcium channel blocker MnCl2 or the inorganic potassium channel blockers BaCl2 or CsCl into the perilymph of the scala vestibuli of the guinea pig. The spatial distribution of the formed histochemical reaction products within the organ of Corti was studied by energy-filtering transmission-electron microscopy. Compared with untreated control ears, the number of the formed precipitates drastically increased at the extracellular side of the lamina reticularis after application of the various inorganic channel blockers. The apical side of the outer hair cells and the intervening Deiter cells were covered …

HistologyTectorial membraneBarium CompoundsGuinea PigsCesiumchemistry.chemical_elementPerilymphCalciumPathology and Forensic MedicineChloridesmedicineAnimalsChemical PrecipitationChannel blockerCochleaLamina reticularisCell BiologyAnatomyCalcium Channel BlockersPerilymphHair Cells Auditory OuterMicroscopy Electronmedicine.anatomical_structurechemistryOrgan of CortiBiophysicsCalciumHair cellElectron Probe MicroanalysisCell and Tissue Research
researchProduct

Study of exotic decay of Cs isotope close to the proton drip line

2020

6 pags., 6 figs. -- 27th International Nuclear Physics Conference (INPC2019) 29 July - 2 August 2019, Glasgow, UK

HistoryProtonGround stateParticle emissionsNuclear TheoryExotic decayProton spectraSpallation reactionsCesium01 natural sciencesLanthanum compounds3100EducationNuclear physicsParticle emissionGermanium compoundsGamma detectors0103 physical sciencesNuclear Physics - ExperimentSpallation010306 general physicsNuclear ExperimentLine (formation)PhysicsLarge Hadron ColliderIsotope010308 nuclear & particles physicsCharged particle arraysCharged particleComputer Science ApplicationsPhysics::Accelerator PhysicsTime distributionFísica nuclearUnbound stateGround stateydinfysiikka
researchProduct

The effect of chronic low-dose environmental radiation on organ mass of bank voles in the Chernobyl Exclusion Zone

2020

Purpose: Animals are exposed to environmental ionizing radiation (IR) externally through proximity to contaminated soil and internally through ingestion and inhalation of radionuclides. Internal organs can respond to radioactive contamination through physiological stress. Chronic stress can compromise the size of physiologically active organs, but studies on wild mammal populations are scarce. The effects of environmental IR contamination on organ masses was studied by using a wild rodent inhabiting the Chernobyl Exclusion Zone (CEZ). Material and Methods: The masses of brain, heart, kidney, spleen, liver and lung were assessed from bank voles (Myodes glareolus) captured from areas across r…

MaleTime Factorsmetsämyyrähealth care facilities manpower and serviceseducationRadiationEnvironment030218 nuclear medicine & medical imagingIonizing radiationChernobylsäteilybiologia03 medical and health sciencessisäelimet0302 clinical medicineMyodes glareolusIngestionAnimalsRadiology Nuclear Medicine and imagingExclusion zoneradioaktiivinen säteilyluonnonvaraiset eläimethealth care economics and organizationsRadionuclideRadiological and Ultrasound TechnologyInhalationradiocesiumArvicolinaeionisoiva säteilyfungiLow dosefood and beveragesDose-Response Relationship RadiationOrgan Sizewild populationsSoil contaminationChernobyl Nuclear Accident030220 oncology & carcinogenesisEnvironmental chemistryinternal organsEnvironmental scienceFemale
researchProduct

Optical non-contact electric field mapping by LIF in Cs vapor

2007

We present experimental and theoretical studies of the possibility of using cesium vapor as a tracer gas for optical non-contact electric field mapping. Optical images of electric field distributions have been obtained.

Materials scienceCesium vaporMolecular physicssymbols.namesakeStark effectElectric fieldTRACERsymbolsMaxwell-Bloch equationsPhysics::Atomic PhysicsAtomic physicsLaser-induced fluorescenceAstrophysics::Galaxy AstrophysicsLaser beams
researchProduct

A monte carlo study of dose rate distribution around the specially asymmetric CSM3-a 137Cs source.

2001

The CSM3 137Cs type stainless-steel encapsulated source is widely used in manually afterloaded low dose rate brachytherapy. A specially asymmetric source, CSM3-a, has been designed by CIS Bio International (France) substituting the eyelet side seed with an inactive material in the CSM3 source. This modification has been done in order to allow a uniform dose level over the upper vaginal surface when this `linear' source is inserted at the top of the dome vaginal applicators. In this study the Monte Carlo GEANT3 simulation code, incorporating the source geometry in detail, was used to investigate the dosimetric characteristics of this special CSM3-a 137Cs brachytherapy source. The absolute do…

Materials scienceRadiological and Ultrasound Technologybusiness.industryRadioactive sourceRadiotherapy Planning Computer-AssistedMonte Carlo methodBrachytherapyDose levelSievert integralLow-Dose Rate BrachytherapyComputational physicsDistribution (mathematics)Cesium RadioisotopesNeoplasmsVaginaDosimetryHumansRadiology Nuclear Medicine and imagingFemaleDose rateNuclear medicinebusinessRadiometryMonte Carlo MethodAlgorithmsPhysics in medicine and biology
researchProduct

Possible impacts of Hg and PAH contamination on benthic foraminiferal assemblages: An example from the Sicilian coast, central Mediterranean

2007

The Palermo and Augusta urban/industrial areas (Sicily) are examples of contaminated coastal environments with a relatively high influx of unregulated industrial and domestic effluents. Three sediment box-cores were collected offshore of these urban/industrial areas in water depths of 60-150 m during two cruises (summers 2003/2004), dated by (210)Pb and (137)Cs, and analysed for total mercury concentration and total polycyclic aromatic hydrocarbon (PAH) concentration. Benthic foraminiferal assemblages were also examined (in terms of their distribution and morphology) to assess the potential use of benthic foraminifera as bioindicators of pollutant input and environmental change in these Med…

Mediterranean climateGeologic SedimentsmercuryEnvironmental Engineeringbenthic foraminiferachemistry.chemical_elementZooplanktonForaminiferaMediterranean seaMediterranean SeaAnimalsEnvironmental ChemistryDominance (ecology)Polycyclic Aromatic HydrocarbonsSicilyWaste Management and DisposalMercury PAHs 210Pb and 137Cs dating Benthic foraminifera Marine sediments SicilybiologyfungiPaleontologySedimentLead Radioisotopesbiology.organism_classificationPollutionMercury (element)PAHSOceanographychemistryCesium RadioisotopesBenthic zoneBioindicatorWater Pollutants ChemicalPb-210 and Cs-137 datingGeologyEnvironmental MonitoringScience of The Total Environment
researchProduct

Desensitization is a property of the cholinergic binding region of the nicotinic acetylcholine receptor, not of the receptor-integral ion channel

1991

AbstractThe reversible acetylcholine esterase inhibitor (−)-physostigmine (eserine) is the prototype of a new class of nicotinic acetylcholine receptor (nAChR) activating ligands: it induces cation fluxes into nAChR-rich membrane vesicles from Torpedo marmorala electric tissue even under conditions of antagonist blocked acetylcholine binding sites (Okonjo, Kuhlmann, Maclicke, Neuron, in press). This suggests that eserine exerts its channel-activating property via binding sites at the nAChR separate from those of the natural transmitter. We now report that eserine can activate the channel even when the receptor has been preincubated (desensitized) with elevated concentrations of acetylcholin…

Nicotinic acetylcholine receptorStereochemistryAcetylcholine-gated cation channelPhysostigmineBiophysicsCesiumIon fluxDesensitizationIn Vitro TechniquesReceptors NicotinicTorpedoBiochemistryIon ChannelsAnticholinesteraseAcetylcholine bindingGanglion type nicotinic receptorStructural BiologyMuscarinic acetylcholine receptor M5GeneticsmedicineAnimalsMolecular BiologyAcetylcholine receptorBinding SitesChemistryCell BiologyBungarotoxinsAcetylcholineNicotinic acetylcholine receptorNicotinic agonistCarbamateBiophysicsCholinergicAcetylcholineEserinemedicine.drugFEBS Letters
researchProduct

Yields of neutron-rich rubidium and cesium isotopes from fast-neutron induced fission of 238U, obtained by studying their release from a thick ISOL t…

2006

Abstract In the framework of the EURISOL project, the production of neutron-rich isotopes of rubidium and cesium has been studied. The intensities of mass-separated beams of rubidium and cesium isotopes generated from a thick 238 UC x target connected to a surface ionizer have been measured. The release properties of 140 Cs and 91 Rb have been investigated. The obtained results allowed us to determine the relative fission yields of rubidium and cesium isotopes with high accuracy.

Nuclear and High Energy PhysicsCesium IsotopeschemistryIsotopeFissionCaesiumRadiochemistrychemistry.chemical_elementNeutronInstrumentationIsotopes of caesiumRubidiumNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron

2015

We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be inter…

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsFOS: Physical sciencesMagnitude (mathematics)01 natural sciencesResonance (particle physics)High Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)Quantum mechanicsPaul-Scherrer InstituteCesium atom0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]NeutronLimit (mathematics)010306 general physicsPhysicsConservation lawmagnetic-momentMagnetic moment010308 nuclear & particles physicsInstrumentation and Detectors (physics.ins-det)QC0793Atomic-Mercury magnetometerElectric dipole momentresonanceQuantum electrodynamicsUltracold neutronsParticle Physics - Experiment
researchProduct