Search results for "Cherenkov detector"
showing 10 items of 52 documents
Performance Studies of Pixel Hybrid Photon Detectors for the LHCb RICH Counters
2006
The Pixel Hybrid Photon Detector is a vacuum tube with a multi-alkali photo cathode, high voltage cross-focused electron optics and an anode consisting of a silicon pixel detector bump-bonded to a readout CMOS electronic chip fully encapsulated in the device. The Pixel HPD fulfils the requirements of the Ring Imaging Cherenkov counters of the LHCb experiment at LHC. The performances of the Pixel HPD will be discussed with reference to laboratory measurements, Cherenkov light imaging in recent beam tests, image distortions due to a magnetic field.
Dual baseline search for muon neutrino disappearance at0.5 eV2<Δm2<40 eV2
2012
The SciBooNE and MiniBooNE collaborations report the results of a νμ disappearance search in the Δ'm2 region of 0.5-40 eV2. The neutrino rate as measured by the SciBooNE tracking detectors is used to constrain the rate at the MiniBooNE Cherenkov detector in the first joint analysis of data from both collaborations. Two separate analyses of the combined data samples set 90% confidence level (CL) limits on νμ disappearance in the 0.5-40 eV2 Δm2 region, with an improvement over previous experimental constraints between 10 and 30 eV2
ALICE T0 detector
2005
T0-the fast timing and trigger detector for the ALICE experiment at CERN LHC-is described. Performance of the T0 prototype measured with a mixture of 6 GeV/c negative pions and kaons is given. The best time resolution (28 ps r.m.s.) was reached with a radiator diameter matching that of the photocathode. The results for all the tested radiator sizes are considerably better than 50 ps-the minimum requirement for the ALICE experiment.
High Precision Momentum Calibration of the Magnetic Spectrometers at MAMI for Hypernuclear Binding Energy Determination
2016
We propose a new method for absolute momentum calibration of magnetic spectrometers used in nuclear physics, using the time-of-flight (TOF), differences of pairs of particles with different masses. In cases where the flight path is not known, a calibration can be determined by using the TOF differences of two pair combinations of three particles. A Cherenkov detector, read out by a radio frequency photomultiplier tube, is considered as the high-resolution and highly stable TOF detector. By means of Monte Carlo simulations it is demonstrated that the magnetic spectrometers at the MAMI electron-scattering facility can be calibrated absolutely with an accuracy $\delta p/p\leq 10^{-4}$, which w…
Simulation and reconstruction of the PANDA Barrel DIRC
2014
Hadronic particle identification (PID) in the barrel region of the PANDA experiment at the new Facility for Antiproton and Ion Research in Europe (FAIR) at GSI, Darmstadt will be provided by a DIRC (Detection of Internally Reflected Cherenkov light) counter. To optimize the performance and reduce the detector cost, detailed simulations of different design elements, such as the width of the radiators, the shape of the expansion volume, and the type of focusing system, were performed using Geant. Custom reconstruction algorithms were developed to match the detector geometry. We will discuss the single photon resolution and photon yield as well as the PID performance for the Barrel DIRC baseli…
Particle Identification with DIRCs at PANDA
2019
The DIRC technology (Detection of Internally Reflected Cherenkov light) offers an excellent possibility to minimize the form factor of Cherenkov detectors in hermetic high energy detectors. The PANDA experiment at FAIR in Germany will combine a barrel-shaped DIRC with a disc-shaped DIRC to cover an angular range of 5 to 140 degrees. Particle identification for pions and kaons with a separation power of 3 standard deviations or more will be provided for momenta between 0.5 GeV/c and 3.5 GeV/c in the barrel region and up to 4 GeV/c in the forward region. Even though the concept is simple, the design and construction of a DIRC is challenging. High precision optics and mechanics are required to…
The large-area hybrid-optics CLAS12 RICH detector: Tests of innovative components
2014
A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab to study the 3D nucleon structure in the yet poorly explored valence region by deep-inelastic scattering, and to perform precision measurements in hadronization and hadron spectroscopy. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors and densely packed and highly segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two…
Technical design report for the $\overline{{\rm{P}}}\mathrm{ANDA}$ Barrel DIRC detector
2019
The $\overline{{\rm{P}}}\mathrm{ANDA}$ (anti-Proton ANnihiliation at DArmstadt) experiment will be one of the four flagship experiments at the new international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. $\overline{{\rm{P}}}\mathrm{ANDA}$ will address fundamental questions of hadron physics and quantum chromodynamics using high-intensity cooled antiproton beams with momenta between 1.5 and 15 GeV/c and a design luminosity of up to 2 × 1032 cm−2 s−1. Excellent particle identification (PID) is crucial to the success of the $\overline{{\rm{P}}}\mathrm{ANDA}$ physics program. Hadronic PID in the barrel region of the target spectrometer will be per…
The PANDA DIRC detectors
2020
Abstract The PANDA experiment at the future Facility for Antiproton and Ion Research (FAIR) will address fundamental questions of hadron physics with unprecedented precision. To reach this goal excellent Particle Identification (PID) is essential over a large range of particle momenta and solid angles. Most of the phase space will be covered by two innovative DIRC (Detection of Internally Reflected Cherenkov light) detectors. The Endcap Disc DIRC and Barrel DIRC will cover the polar angle range from 5 to 22°and 22 to 140°, respectively. Both detectors rely on high precision optical components, lifetime-enhanced Microchannel Plate PMTs (MCP-PMTs), and fast readout electronics.
The three-spectrometer facility at the Mainz microtron MAMI
1998
Abstract A set-up of three high-resolution magnetic spectrometers, for simplicity named A, B and C, has been built as the central facility for the precise determination of double and triple coincidence cross sections of hadron knock-out and meson production through the scattering of electrons at the Mainz microtron MAMI. The spectrometers A and C with point-to-point optics in the dispersive plane and parallel-to-point optics in the non-dispersive plane have a solid angle of 28 msr and a momentum acceptance of 20 and 25%, respectively. They each consist of a quadrupole, a sextupole and two dipole magnets, reaching maximum momenta of 735 and 550 MeV/c, respectively. The spectrometer B has a s…