Selective flow-injection biamperometric determination of sulfur-containing amino acids and structurally related compounds

2001

Abstract A simple and selective flow-injection method for the determination of cysteine and methionine is proposed. The method is based on the reaction of the amino acid with chloramine-T and the subsequent reaction of the excess of chloramine-T with an acidic solution of iodide producing a stoichiometric amount of tri-iodide (diminution of the flow-injection analysis (FIA) peak) which is determined biamperometrically using two platinum electrodes polarized at 100 mV. The calibration graph is linear up to 10 μg ml−1 of cysteine and 30 μg ml−1 of methionine; the limit of detection is 0.06 and 0.1 μg ml−1; the repeatability (also as percent of a series of 70 continuous FIA peaks of 5 μg ml−1 …

Detection limitchemistry.chemical_classificationMethionineChromatographyIodideCystineBiochemistryAnalytical ChemistryAmino acidchemistry.chemical_compoundchemistryChloramine-TEnvironmental ChemistryQuantitative analysis (chemistry)SpectroscopyCysteineAnalytica Chimica Acta
researchProduct

Flow injection biamperometric determination of chloramine-T in environmental, pharmaceutical and veterinary samples

2000

Abstract A flow injection assembly for the determination of chloramine-T is proposed. The sample (213 μl) is inserted into the carrier, de-ionized water flowing at 4.1 ml min−1. This carrier merges with a mixture of potassium iodide and sulphuric acid, and the resulting solution flows to the flow cell through a reactor 66 cm long. The chloramine-T oxidises the iodide to tri-iodide. The resulting iodide/iodine ratio is biamperometrically tested. The calibration graph is linear up to 65 μg ml−1 chloramine-T; the limit of detection is 0.5 μg ml−1; the relative standard deviation (r.s.d) of the calibration slope is 2.8% for a series of eight independent calibrations. The r.s.d. of a series of 7…

Detection limitchemistry.chemical_classificationVeterinary medicineCalibration curveIodideAnalytical chemistrychemistry.chemical_elementIodineBiochemistryAnalytical Chemistrychemistry.chemical_compoundWastewaterchemistryChloramine-TCalibrationEnvironmental ChemistryQuantitative analysis (chemistry)SpectroscopyAnalytica Chimica Acta
researchProduct

Differential effects of cysteine and methionine residues in the antioxidant activity of human serum albumin

2005

Antioxidant properties of human serum albumin (HSA) may explain part of its beneficial role in various diseases related to free radical attack. In the present study, the antioxidant role of Cys and Met was studied by copper-mediated oxidation of human low density lipoproteins and by free radical-induced blood hemolysis which essentially assessed metal-chelating and free radical scavenging activities, respectively. Mild conditions were set up to specifically modify Cys and Met residues by N-ethylmaleimide (NEM) and chloramine T treatments, respectively. We found that Met and Cys accounted for 40-80% of total antioxidant activity of HSA. Copper binding to HSA was decreased by about 50% with c…

Time FactorsAntioxidantFree Radicalsmedicine.medical_treatmentDithionitrobenzoic AcidHemolysisBiochemistryAntioxidantsTosyl Compoundschemistry.chemical_compoundMethioninemedicineHumansChelationCysteineSerum AlbuminMethionineDose-Response Relationship DrugChloraminesFree Radical ScavengersGeneral MedicineFree radical scavengerHuman serum albuminmedicine.diseaseHemolysisLipoproteins LDLOxygenOxidative StresschemistryBiochemistryEthylmaleimideChloramine-TOxidation-ReductionCopperPhenanthrolinesProtein Bindingmedicine.drugCysteineFree Radical Research
researchProduct