Search results for "Cobalt-60"
showing 4 items of 4 documents
Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations
2014
Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a …
Study of encapsulated T170m sources for their potential use in brachytherapy
2010
Purpose: High dose-rate (HDR) brachytherapy is currently performed with {sup 192}Ir sources, and {sup 60}Co has returned recently into clinical use as a source for this kind of cancer treatment. Both radionuclides have mean photon energies high enough to require specific shielded treatment rooms. In recent years, {sup 169}Yb has been explored as an alternative for HDR-brachytherapy implants. Although it has mean photon energy lower than {sup 192}Ir, it still requires extensive shielding to deliver treatment. An alternative radionuclide for brachytherapy is {sup 170}Tm (Z=69) because it has three physical properties adequate for clinical practice: (a) 128.6 day half-life, (b) high specific a…
ESR response to 60Co-rays of ammonium tartrate pellets using as additive
2007
Abstract This work presents experimental results regarding a new ammonium tartrate blend for ESR dosimetry, with a higher sensitivity and a lower lowest detectable dose (LDD) to Co 60 γ -rays than the recently used pure ammonium tartrate. The blend composed by ammonium tartrate and gadolinium-oxide ( Gd 2 O 3 ) shows a greater sensitivity ( ∼ 2 times) and a smaller LDD than ammonium tartrate. The increased sensitivity was mainly attributed to the great atomic number ( Z = 64 ) of gadolinium, that increases the effective atomic number of the blend; the interaction probability with photons and consequently the radical yield is therefore enhanced. Moreover ammonium tartrate with Gd 2 O 3 has a…
Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons
2009
Purpose: The region of electronic disequilibrium near photon-emitting brachytherapysources of high-energy radionuclides ( C 60 o , C 137 s , I 192 r , and Y 169 b ) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPEMonte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to sourcephotons, x rays, and bremsstrahlung; source β − , Auger electrons, and internal conversionelectrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electrondose contribution t…