Search results for "Coherence tomography"

showing 10 items of 150 documents

Optical coherence tomography of chorioretinal and choroidal folds

2007

. Purpose:  To report the optical coherence tomography (OCT) findings in cases of chorioretinal and choroidal folds. Methods:  Eight subjects with folds of the fundus of the eye were examined with fundus photography, fluorescein angiography, B-scan ultrasonography and Stratus OCT. Results:  Two types patterns were found on OCT. Five cases showed undulating retinal as well as retinal pigment epithelial lines of normal thickness; these were defined as chorioretinal folds. The posterior vitreous surface often adhered to the crests of the folds only. Three cases exhibited a wavy appearance of the retinal pigment epithelium and a flat retinal surface; these were classified as choroidal folds. Co…

AdultMalevisual acuitygenetic structuresFundus OculiDiagnosis Differentialchemistry.chemical_compoundRetinal DiseasesOptical coherence tomographyPhotographymedicineHumansFluorescein AngiographyPigment Epithelium of EyeAgedChoroidal foldsRetinal pigment epitheliummedicine.diagnostic_testSettore MED/30 - Malattie Apparato Visivobusiness.industryFundus photographyRetinalChoroid DiseasesAnatomyMiddle AgedFluorescein angiographyeye diseasesOphthalmologymedicine.anatomical_structureOCTchemistryFemalesense organsUltrasonographybusinessNormal thicknessTomography Optical CoherenceActa Ophthalmologica Scandinavica
researchProduct

Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT

2021

Purpose To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). Methods We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. Results Mean LV wa…

Adultmedicine.medical_specialtyBiometryAnterior ChamberSignificant negative correlationPositive correlationSwept-source Fourier domainCorrelationLens thicknessOphthalmologyLens CrystallineHumansMedicineOptical coherence tomographybusiness.industrySpur-to-spurReproducibility of ResultsMean ageAxial lengthWhite-to-whiteMiddle AgedClinical routineCrystalline lens riseAxial Length Eyemedicine.anatomical_structureLens (anatomy)Original ArticlebusinessTomography Optical CoherenceOptometryJournal of Optometry
researchProduct

Chromatic and achromatic visual fields in relation to choroidal thickness in patients with high myopia: A pilot study

2018

Purpose. - To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. Methods. - All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. Results. - We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, an…

Adultmedicine.medical_specialtyVisual perceptiongenetic structuresColorPilot ProjectsVisual systemSeverity of Illness IndexContrast SensitivityOphthalmoscopyYoung Adult03 medical and health sciences0302 clinical medicineOptical coherence tomographyOphthalmologyHigh myopiaMyopiamedicineHumansMotion perceptionContrast sensitivityColor Perception TestsColor Visionmedicine.diagnostic_testVisual pathwayChoroidbusiness.industryOrgan SizeMiddle AgedSubjective refractioneye diseasesVisual fieldOphthalmoscopyOphthalmologyKoniocellular cellChoroidal thickness030221 ophthalmology & optometrysense organsVisual FieldsbusinessVision fieldColor PerceptionTomography Optical Coherence030217 neurology & neurosurgery
researchProduct

Serum neurofilament levels reflect outer retinal layer changes in multiple sclerosis

2021

Background: Serum neurofilament light chain (sNfL) and distinct intra-retinal layers are both promising biomarkers of neuro-axonal injury in multiple sclerosis (MS). We aimed to unravel the association of both markers in early MS, having identified that neurofilament has a distinct immunohistochemical expression pattern among intra-retinal layers. Methods: Three-dimensional (3D) spectral domain macular optical coherence tomography scans and sNfL levels were investigated in 156 early MS patients (female/male: 109/47, mean age: 33.3 ± 9.5 years, mean disease duration: 2.0 ± 3.3 years). Out of the whole cohort, 110 patients had no history of optic neuritis (NHON) and 46 patients had a previous…

Advances in Neuroimaging0301 basic medicinePathologymedicine.medical_specialtyNeurofilamentNeurofilament lighttranslationneuroimmunologymultiple sclerosisserum neurofilament03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOptical coherence tomographyMedicineOptic neuritisRC346-429Original Researchoptic neuritisPharmacologyoptical coherence tomographymedicine.diagnostic_testbusiness.industryMultiple sclerosisRetinalmedicine.disease030104 developmental biologyNeuroimmunologyNeurologychemistryNeurology. Diseases of the nervous systemNeurology (clinical)business030217 neurology & neurosurgeryTherapeutic Advances in Neurological Disorders
researchProduct

Ocular biometry with swept-source optical coherence tomography

2020

This study aimed to summarize the outcomes reported when swept-source optical coherence tomography (SS-OCT) is used for ocular biometry. A literature search was performed to identify publications reporting clinical outcomes of patients measured with commercial SS-OCT. Twenty-nine studies were included in this review. A comprehensive analysis of the available data was performed, focusing on parameters used for intraocular lens (IOL) power calculation in cataract surgery, including keratometry, central corneal thickness, white-to-white distance, anterior chamber depth, lens thickness, axial length, IOL power, and pupil diameter. Different metrics for repeatability, reproducibility, and agreem…

Biometrygenetic structuresAnterior Chambermedicine.medical_treatmentIntraocular lensCataractlaw.invention03 medical and health sciences0302 clinical medicineOptical coherence tomographyLens thicknesslawHumansMedicineLenses IntraocularReproducibilitymedicine.diagnostic_testKeratometerbusiness.industryReproducibility of ResultsGold standard (test)RepeatabilityCataract surgeryeye diseasesSensory SystemsAxial Length EyeOphthalmology030221 ophthalmology & optometryOptometrySurgerysense organsbusinessTomography Optical Coherence030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Site-Coded Oral Squamous Cell Carcinoma Evaluation by Optical Coherence Tomography (OCT): A Descriptive Pilot Study

2022

Optical Coherence Tomography (OCT) is an emerging non-invasive method for oral diagnostics, proving to be a practicable device for epithelial and subepithelial evaluation. The potential validity of OCT in oral cancer assessment has been explored but, to date, there are very few investigations conducted with a systematic comparison between clinical/histological and OCT parameters, especially in strict reference to the anatomical site-codification of the oral mucosa. In this regard, our study performed a two-steps evaluation (in vivo OCT and histological investigations) of suspected OSCCs, progressively recruited, using as references the OCT images of the same site-coded healthy mucosa, to pr…

Cancer Researchoptical coherence tomography; early diagnosis; oral cancer; diagnostic pattern; optical biopsyoptical biopsyoptical coherence tomographyOncologyoral cancerdiagnostic patternearly diagnosis
researchProduct

“In situ” corneal and contact lens thickness changes with high resolution OCT

2012

Purpose: To show the utility of high resolution spectral domain optical coherence tomography (HR SOCT) for the in situ evaluation of epithelial, stromal and contact lens (CL) thickness changes under closed-eye conditions without lens removal. Settings: Clinical and Experimental Optometry Research Lab, University of Minho, Portugal. Methods: Eight young healthy patients wore a thick soft CL during 90 minutes under closed-eye conditions and measures of epithelial and stromal corneal thickness were obtained at regular intervals using a HR SOCT (Copernicus HR, Optopol Tech. SA, Poland). Results: Minimal changes in epithelial thickness were detected with a transient statistically significant inc…

Corneacontact lensesScience & Technologygenetic structuresOCTepithelial thicknessCoherence tomographysense organsedemaeye diseasesstromal thickness
researchProduct

Response by Meneveau and Ecarnot to Letter Regarding Article, “Optical Coherence Tomography to Optimize Results of Percutaneous Coronary Intervention…

2017

We read with interest the letters by Vallurupalli and Uretsky and also Dr Nadir relating to the results of the DOCTORS study (Does Optical Coherence Tomography Optimize Results of Stenting).1 We thank the authors for their insightful remarks. Vallurupalli and Uretsky raise an interesting point when they underline that a prolonged inflation time is superior to a rapid inflation/deflation technique in terms of both stent expansion and apposition. We acknowledge that we did not take stent inflation time into account in the case report form of the DOCTORS study. The arguments put forward by Vallurupalli and Uretsky suggest that this variable should be systematically recorded and reported. Howev…

Coronary angiographymedicine.medical_specialtyAcute coronary syndromemedicine.medical_treatment030204 cardiovascular system & hematologyCoronary Angiography03 medical and health sciencesPercutaneous Coronary Intervention0302 clinical medicineOptical coherence tomographyPhysiology (medical)medicineHumansMedical physicsIn patient030212 general & internal medicineAcute Coronary SyndromeCase report formmedicine.diagnostic_testbusiness.industryST elevationPercutaneous coronary interventionStentmedicine.diseaseCoronary VesselsSurgeryTreatment OutcomeStentsCardiology and Cardiovascular MedicinebusinessTomography Optical CoherenceCirculation
researchProduct

In Vitro Measurement of Strain Localization Preceding Dissection of the Aortic Wall Subjected to Radial Tension

2020

AbstractBackgroundAortic dissection (AD) is a common pathology and challenging clinical problem. A better understanding of the biomechanical effects preceding its initiation is essential for predicting adverse events on a patient-specific basis. Moreover, the predictability of patient-specific biomechanics-based computational models is hampered by uncertainty about boundary conditions and material properties.ObjectivePredisposition of thoracic aortic aneurysms (TAA) to ADs can be related to the degradation of biomechanically important constituents in the aortic wall of TAAs. The goal of the present study is to develop a new methodology to measure strain fields in aortic tissues subjected to…

Digital image correlationMaterials scienceAortic dissectionAerospace EngineeringDissection (medical)030204 cardiovascular system & hematologyRadial tensile test01 natural sciencesThoracic aortic aneurysm010309 optics03 medical and health sciencesSpeckle pattern0302 clinical medicineAneurysmmedicine.artery0103 physical sciencesmedicineThoracic aortaStrain fieldTensile testingAortic dissectionOptical coherence tomographyMechanical EngineeringDigital image correlationSettore ING-IND/34 - Bioingegneria Industriale[SPI.MECA.BIOM]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph]medicine.diseaseMechanics of MaterialsRadial stiffnessBiomedical engineering
researchProduct

The Usefulness of Optical Coherence Tomography in Disease Progression Monitoring in Younger Patients with Relapsing-Remitting Multiple Sclerosis: A S…

2022

The purpose of the study was to assess the usefulness of optical coherence tomography (OCT) in the detection of the neurodegenerative process in younger patients with multiple sclerosis (MS). The study group consisted of 61 patients with a relapsing remitting course of MS (mean age 36.4 ± 6.7 years) divided into two groups: short (≤5 years) and long (>10 years) disease duration. OCT, P300 evoked potential, Montreal Cognitive Assessment, and performance subtests (Picture Completion and Digit Symbol) of the Wechsler Adult Intelligence Scale were performed in all patients. Mean values of most parameters assessed in OCT (pRNFL Total, pRNFL Inferior, pRNFL Superior, pRNFL Temporalis, mRNFL, G…

General Medicinemultiple sclerosis; optical coherence tomography; neurodegeneration; cognitive impairment; disease monitoringJournal of Clinical Medicine
researchProduct