Search results for "Coherence"
showing 10 items of 905 documents
Intra- and Interhemispheric Electroencephalogram Coherence in Siblings Discordant for Schizophrenia and Healthy Volunteers
1997
Former studies had pointed to an increased electroencephalogram (EEG) coherence in schizophrenics, but it remained unsolved whether this deviation represents the premorbid state or is only a consequence of the current or previous schizophrenic episodes. To clarify this question, we tested the hypothesis that subjects at elevated risk also reveal higher coherences compared to healthy controls. For that, intra- and interhemispheric EEG coherences were investigated in untreated schizophrenics, their healthy siblings, and healthy controls. Differences were only found regarding the intrahemispheric coherences. Both in schizophrenics and, even though to a lesser degree, in their siblings signific…
Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size - the MIPH Eye&Health …
2016
Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of +3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 s…
Effect of age in the ciliary muscle during accommodation: Sectorial analysis
2017
Abstract Purpose To compare changes in the ciliary muscle area at different sectors between pre-presbyopic and presbyopic eyes during accommodation by means of an anterior segment optical coherence tomographer (OCT). Methods The anterior ciliary muscle area was measured in 20 healthy and phakic pre-presbyopic eyes, whose mean age was 23.3 ± 4.4 years, and in 20 healthy and phakic presbyopic eyes, whose mean age was 46.5 ± 5.2 years. The relative change in the cross-sectional area of the ciliary muscle was measured at the nasal, inferior, and temporal sectors between 0 and −3 D of vergence, in −1 D step. A linear model was used to assess the correlation of each eye parameter with the accommo…
Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer
2018
Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…
The difficulty of the postural control task affects multi-muscle control during quiet standing
2016
The aim of this study was to compare the electromyographic (EMG) coherence between the lower limb and the core muscles when carrying out two postural tasks at different difficulty levels. EMG was recorded in 20 healthy male subjects while performing two independent quiet standing tasks. The first one involved a bipedal stance with the eyes open, while the second consisted of a dominant unipedal stance also with the eyes open. The obtained EMG signals were analysed by computing estimations of EMG–EMG coherence between muscle pairs, both singly (single-pair estimations) and combined (pooled estimations). Pooled and single coherence of anterior, posterior, core, antagonist and mixed pairs of m…
Perceived Racial/Ethnic Discrimination and Psychological Outcomes Among Adult International Adoptees in Finland: Moderating Effects of Social Support…
2015
Quantitative literature on international adoptees and racial/ethnic discrimination is lacking despite results in qualitative studies from Europe and the United States that have consistently indicated how racism constantly complicates adoptees' everyday lives. To advance the literature, the present study examined the prevalence of perceived racial/ethnic discrimination among 213 adult international adoptees in Finland (59.6% women and 40.4% men, mean age 24.1 years), and the association between perceived racial/ethnic discrimination and psychological well-being indicators, including psychological distress and sleeping problems. In addition, we examined social support and sense of coherence a…
Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability
2001
Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…
Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.
2020
To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p 0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …
Complex network analysis of resting-state fMRI of the brain.
2016
Due to the fact that the brain activity hardly ever diminishes in healthy individuals, analysis of resting state functionality of the brain seems pertinent. Various resting state networks are active inside the idle brain at any time. Based on various neuro-imaging studies, it is understood that various structurally distant regions of the brain could be functionally connected. Regions of the brain, that are functionally connected, during rest constitutes to the resting state network. In the present study, we employed the complex network measures to estimate the presence of community structures within a network. Such estimate is named as modularity. Instead of using a traditional correlation …
Inter-joint coordination of posture on a seesaw device
2016
Even though specific adjustments of the multi-joint control of posture have been observed when posture is challenged, multi-joint coordination on a seesaw device has never been accurately assessed. The current study was conducted in order to investigate the multi-joint coordination when subjects were standing on either a seesaw device or on a stable surface, with the eyes open or closed. Eighteen healthy active subjects were recruited. A principal component analysis and a Self-Organizing Maps analysis were performed on the joint angles in order to detect and characterize dominant coordination patterns. Intermuscular EMG coherence was analysed in order to assess the neurophysiological mechan…