Search results for "Coherence"
showing 10 items of 905 documents
Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
2009
PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …
Feasibility and reproducibility of electroencephalography-based corticokinematic coherence
2020
Corticokinematic coherence (CKC) is the phase coupling between limb kinematics and cortical neurophysiological signals, reflecting cortical processing of proprioceptive afference, and it is reproducible when estimated with magnetoencephalography (MEG). However, feasibility and reproducibility of CKC based on electroencephalography (EEG) is still unclear and is the primary object of the present report. Thirteen healthy right-handed volunteers (seven females, 21.7 ± 4.3 yr) participated in two combined MEG/EEG sessions 12.6 ± 1.3 mo apart. Participants' dominant and nondominant index finger was continuously moved at 3 Hz for 4 min separately using a pneumatic-movement actuator. Coherence was …
Interbrain emotional connection during music performances is driven by physical proximity and individual traits.
2021
How musical emotions and the pleasure derived from music, regardless of the musical valence, can be shared between individuals is a fascinating question, and investigating it can shed light on the function of musical reward. We carried out our investigations in a natural setting during an international competition for orchestra conductors. Participants (n = 15) used a dedicated smartphone app to report their subjective emotional experiences in real time while we recorded their cerebral activity using electroencephalography and their electrodermal activity. The overall behavioral real-time behavioral ratings suggest a possible social influence on the reported and felt pleasure. The physicall…
Peripapillary Choroidal Thickness and Choroidal Area in Glaucoma, Ocular Hypertension and Healthy Subjects by SD-OCT.
2015
Background: The exact pathogenesis of open angle glaucoma and ocular hypertension remains unclear. Hemodynamic influences are discussed as potential risk factors and the choroid may play an important role in the pathogenesis of open angle glaucoma or ocular hypertension. The current study investigates peripapillary choroidal thickness and choroidal area in patients with open angle glaucoma, subjects with ocular hypertension and healthy subjects using spectral-domain OCT. It furthermore assesses the association between peripapillary choroidal thickness and age, central corneal thickness, refractive error and intraocular pressure. Patients and Methods: Prospectively recorded data of 213 eyes …
Is sense of coherence a predictor of lifestyle changes in subjects at risk for type 2 diabetes?
2015
Objective: To determine whether the sense of coherence (SOC) could predict the outcome of an 18-month lifestyle intervention program for subjects at risk of type 2 diabetes. Methods: Subjects at high risk of type 2 diabetes mellitus were recruited to a low-intensity lifestyle intervention program by their general practitioners. Weight reduction ≥5% and improvement in exercise capacity of ≥10% from baseline to follow-up indicated a clinically significant lifestyle change. SOC was measured using the 13-item SOC questionnaire. Results: The study involved 213 subjects with a mean body mass index of 37 (SD ± 6). Complete follow-up data were obtained for 131 (62%). Twenty-six participants had cli…
Sense of coherence, academic performance and professional vocation in Certified Nursing Assistant students
2019
BACKGROUND: The sense of coherence (SOC) of the salutogenic health model explains why people in stressful situations are able to maintain or even improve their health. There are some studies on which measures are more effective to reduce stress in Nursing assistant students. There are no studies that link SOC with the two key aspects in the prevention of stress in Nursing assistant students: the motivation of pursuing this profession and the academic level. OBJECTIVES: To explore the salutogenic paradigm among Nursing assistant students in a region of Spain (Comunitat Valenciana). DESIGN: Cross-sectional, analytical and exploratory study carried out in 2016. METHODS: Students of the first y…
Enabling resources in people with dementia: a qualitative study about nurses’ strategies that may support a sense of coherence in people with dementia
2015
Aims and objectives To explore nurses’ strategies that may support the sense of coherence in people with dementia. Background People with dementia are often described as people with no resources, people who need support from family or from healthcare personnel to function in everyday life. Despite the disease, some people still have the resources needed to cope well with parts of their lives and experience coherence. To date, no research has explored any nurses’ strategies that may support the sense of coherence in people with dementia. Design The design of the study is qualitative and exploratory. Methods Data were collected by participant observation and focus group interviews. Sixteen re…
Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system
2014
Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…
Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography
2019
ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …
Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients
2011
PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and…