Search results for "Coherence"
showing 10 items of 905 documents
OPTICAL COHERENCE TOMOGRAPHIC FINDINGS IN BIETTI’S CRYSTALLINE TAPETORETINAL DYSTROPHY
2014
Purpose: To report the optical coherence tomography (OCT) findings of Bietti crystalline tapetoretinal dystrophy. Design: Observational case report. Methods: A subject with Bietti crystalline tapetoretinal dystrophy was evaluated with ophthalmoscopy, fluorescein angiography, and OCT (Stratus). Results: OCT showed thinning and hyporeflectivity of the outer nuclear layer in the macula due to photoreceptor degeneration. The retinal areas showing atrophy of the retinal pigment epithelium displayed greater penetration of the optical beam into the choroid and visualization of residual choroidal vessels. The hyperreflective band normally seen under the neurosensory retina was extremely wide when a…
Magnetic resonance imaging and optical coherence tomography correlations in multiple sclerosis beyond anatomical landmarks.
2020
Abstract Objective To investigate multiple sclerosis (MS) optical coherence tomography (OCT) cross-sectional correlations with central nervous system (CNS) magnetic resonance imaging (MRI). Material and methods Peripapillary retinal nerve fiber layer (pRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner (INL) and outer nuclear layer (ONL) of 54 relapsing remitting (RRMS) and 38 progressive (PMS, 9 primary and 29 secondary) patients were measured. With less than 3 months brain parenchymal fraction (BPF), spinal cord (SC), total gray matter (GM) and white matter volumes were calculated. Demographical and clinical data was compared according to the history of optic neuritis (H…
A novel automated segmentation method for retinal layers in OCT images proves retinal degeneration after optic neuritis.
2015
Aim The evaluation of inner retinal layer thickness can serve as a direct biomarker for monitoring the course of inflammatory diseases of the central nervous system such as multiple sclerosis (MS). Using optical coherence tomography (OCT), thinning of the retinal nerve fibre layer and changes in deeper retinal layers have been observed in patients with MS. Here, we first compare a novel method for automated segmentation of OCT images with manual segmentation using two cohorts of patients with MS. Using this method, we also aimed to reproduce previous findings showing retinal degeneration following optic neuritis (ON) in MS. Methods Based on a 5×5 expansion of the Prewitt operator to efficie…
Dynamics, alterations, and consequences of minimally invasive intraocular pressure elevation in rats.
2014
PURPOSE: An important, yet not exclusive, aspect of primary open angle glaucoma is elevated intraocular pressure (IOP) profiles within fluctuations and pressure peaks. The study aimed at establishing minimally invasive methods for recurrent IOP elevation in rats to investigate the impact of IOP dynamics and pathomorphologic retinal alterations during and after IOP elevation. METHODS: Intraocular pressure was elevated unilaterally in Long Evans rats to a level of ≈35 mm Hg for 1 hour in a total of 30 manipulations within 6 weeks, by using two methods: (1) suction-cup oculopression and (2) loop-adjusted oculopression. Retinal thickness (RT) was measured via optical coherence tomography (OCT),…
Rheological and Flocculation Analysis of Microfibrillated Cellulose Suspension Using Optical Coherence Tomography
2018
A sub-micron resolution optical coherence tomography device was used together with a pipe rheometer to analyze the rheology and flocculation dynamics of a 0.5% microfibrillated cellulose (MFC) suspension. The bulk behavior of the MFC suspension showed typical shear thinning (power-law) behavior. This was reflected in a monotonously decreasing floc size when the shear stress exceeded the yield stress of the suspension. The quantitative viscous behavior of the MFC suspension changed abruptly at the wall shear stress of 10 Pa, which was reflected in a simultaneous abrupt drop of the floc size. The flocs were strongly elongated with low shear stresses. With the highest shear stresses, the flocs…
The Romanian Prezidentialized Consultative Referendum. Eating Apples from a Poisonous Tree? Personal and Teleological Interpretations
2019
Abstract Through this article, we propose an (original) analytical approach on the consultative referendum of May 2019 and a wider critical landscape regarding the consultative referendum institution by enforcing a teleological interpretation. In this sense, we propose three sections. We will start with a short overview on the use of the consultative referendum in the recent years of Romanian democracy. In the second section we will focus on the consultative referendum from 26 May, 2019. In the third section we will ask the Founding Fathers of the Constitution for an “opinion” regarding the possibilities and impossibilities of the consultative referendum.
Intraocular lens centration and stability: efficacy of current technique and technology
2008
Purpose of review The manuscript presents a review of recently published studies analyzing different methodologies to assess centration and stability of intraocular lenses after implantation. Recent findings Considering that there is no current gold standard for centration and stability of intraocular lenses after implantation, we have summarized the different techniques used clinically for intraocular lenses centration and stability estimation. We have described the use of Scheimpflug imaging, the anterior segment optical coherence tomography and photography analysis used for lens position estimation. Techniques used to assess lens rotation are based on image analysis on digital retroillum…
Classification of SD-OCT Volumes for DME Detection: An Anomaly Detection Approach
2016
International audience; Diabetic Macular Edema (DME) is the leading cause of blindness amongst diabetic patients worldwide. It is characterized by accumulation of water molecules in the macula leading to swelling. Early detection of the disease helps prevent further loss of vision. Naturally, automated detection of DME from Optical Coherence Tomography (OCT) volumes plays a key role. To this end, a pipeline for detecting DME diseases in OCT volumes is proposed in this paper. The method is based on anomaly detection using Gaussian Mixture Model (GMM). It starts with pre-processing the B-scans by resizing, flattening, filtering and extracting features from them. Both intensity and Local Binar…
Model-Based Evaluation of Methods for Respiratory Sinus Arrhythmia Estimation
2021
OBJECTIVE: Respiratory sinus arrhythmia (RSA) refers to heart rate oscillations synchronous with respiration, and it is one of the major representations of cardiorespiratory coupling. Its strength has been suggested as a biomarker to monitor different conditions, and diseases. Some approaches have been proposed to quantify the RSA, but it is unclear which one performs best in specific scenarios. The main objective of this study is to compare seven state-of-the-art methods for RSA quantification using data generated with a model proposed to simulate, and control the RSA. These methods are also compared, and evaluated on a real-life application, for their ability to capture changes in cardior…
Structural invariance and stability of sense of coherence: A longitudinal analysis of two groups with different employment experiences
2005
This 5-year follow-up study investigated the structure and the factorial invariance of the 13-item sense of coherence (SOC) scale (Antonovsky, 1987a) in two employment groups (unemployment/lay-off experiences vs. continuous full-time employment) and across two measurement times. In addition, the stability of SOC between these two employment groups was compared. The postal questionnaire data was collected twice, in 1992 and in 1997. The participants were Finnish technical designers (N=352) aged between 25 and 40 years in 1992. A total of 51% of the investigated participants had been employed full-time during the 5-year follow-up period and 49% had been unemployed and/or laid off for a total …