Search results for "Coherence"

showing 10 items of 905 documents

The mediating role of optimism in the relations between sense of coherence, subjective and psychological well-being among late adolescents

2015

Abstract The purpose of this study was to examine whether optimism is a mediator between sense of coherence, subjective well-being and psychological well-being among late adolescents. Two hundred and eleven participants completed the Sense of Coherence Scale, the Life Orientation Test-Revised, the Satisfaction With Life Scale, the Positive and Negative Affect Schedule, and the Psychological Well-Being Scale. Results of path analysis revealed both direct and indirect effects of sense of coherence on subjective and psychological well-being measures, suggesting that optimism served as a partial mediator. The mediating role of optimism may be more fully understood within the framework of the se…

media_common.quotation_subjectOptimism; Sense of coherence; Subjective and psychological well-being; Late adolescentsDispositional optimismDevelopmental psychologyOptimismPositive and Negative Affect SchedulePsychological well-beingLife orientationPath analysis (statistics)PsychologySocial psychologyGeneral PsychologySense of coherencemedia_commonPersonality and Individual Differences
researchProduct

Physical activity and sense of coherence : a meta-analysis

2020

The salutogenic model of health proposes that sense of coherence, a multi-dimensional construct representing individuals’ perceptions that their environment is comprehensible, manageable, and meaningful, is a key determinant of stress management and well-being. Generalized resistance resources such as preventive health orientation, material resources, and social support are proposed as determinants of sense of coherence. Health behaviors, particularly physical activity, are proposed as indicators of a preventive health orientation and predictors of sense of coherence. We synthesized research on the relationship between physical activity and sense of coherence using three-level meta-analysis…

media_common.quotation_subjectPhysical activityphysical activitysense of coherenceliikuntakoherenssi050105 experimental psychology03 medical and health sciences0302 clinical medicinehealth behaviorPerception0501 psychology and cognitive sciencesApplied Psychologymedia_commonexercise05 social sciences030229 sport sciencessalutogenic model of healthMeta-analysisterveyskäyttäytyminengeneralized resistance resourcesHealth behaviorPsychologyConstruct (philosophy)fyysinen aktiivisuusCognitive psychologySense of coherence
researchProduct

Suppression of phase ambiguity in digital holography by using partial coherence or specimen rotation

2008

In this paper we present two approaches for extracting the surface profile as well as obtaining 3D imaging of near field objects by usage of partial coherence and digital holography. In the first approach a light source with given temporal partial coherence is used to illuminate a near field object. The reflected light is interfered with the reference source. By computing the local contrast of the generated fringes one may estimate the 3D topography and the profile of the object. This approach extracts the 3D information from a single image, and its accuracy does not depend on triangulation angle like in fringe projection methods. The second approach is tomography based. There we illuminate…

medicine.diagnostic_testComputer sciencebusiness.industryMaterials Science (miscellaneous)Image processingNear and far fieldIndustrial and Manufacturing EngineeringStructured-light 3D scannerPhase shifting interferometryOpticsOptical coherence tomographyApproximation errorReflection (physics)medicineSpatial frequencyTomographyBusiness and International ManagementbusinessPartial coherenceDigital holographyCoherence (physics)Applied Optics
researchProduct

The Association Between Quantitative Flow Ratio and Intravascular Imaging-defined Vulnerable Plaque Characteristics in Patients With Stable Angina an…

2021

Background: This study aimed to examine whether quantitative flow ratio (QFR), an angiography-based computation of fractional flow reserve, was associated with intravascular imaging-defined vulnerable plaque features, such as thin cap fibroatheroma (TCFA) in patients with stable angina, and non-ST-segment elevation acute coronary syndrome.Methods: Patients undergoing optical coherence tomography (OCT) or intravascular ultrasound (IVUS) examinations were identified from two prospective studies and their interrogated vessels were assessed with QFR. Lesions in the OCT cohort were classified into tertiles: QFR-T1 (QFR ≤ 0.85), QFR-T2 (0.85 < QFR ≤ 0.93), and QFR-T3 (QFR > 0.93). L…

medicine.medical_specialtyAcute coronary syndromeLumen (anatomy)Fractional flow reserveCardiovascular Medicine030204 cardiovascular system & hematologymedicine.disease_causequantitative flow ratio (QFR)03 medical and health sciences0302 clinical medicineInternal medicinefractional flow reserve (FFR)Intravascular ultrasoundmedicineDiseases of the circulatory (Cardiovascular) systemoptical coherence tomography (OCT)030212 general & internal medicineProspective cohort studyOriginal Researchintravascular ultrasound (IVUS)medicine.diagnostic_testbusiness.industryFibrous capmedicine.diseaseVulnerable plaquemedicine.anatomical_structureRC666-701AngiographyCardiologyplaque vulnerabilityCardiology and Cardiovascular MedicinebusinessFrontiers in Cardiovascular Medicine
researchProduct

Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer

2020

PURPOSE To evaluate the agreement between different parameters obtained with 2 swept-source optical coherence tomography (SS-OCT)-based biometers and 1 Scheimpflug camera with partial coherence interferometry (PCI). SETTING Single center, Oftalvist, Alicante, Spain. DESIGN Prospective case series. METHODS Biometry was performed in 49 eyes using 3 optical biometers: ANTERION SS-OCT, IOLMaster 700 SS-OCT, and Pentacam AXL PCI. Keratometry (K), J0 and J45 vectors, anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white (WTW), lens thickness (LT), and axial length (AL) were measured with each device. Bland-Altman analysis was applied. RESULTS This study comprises 49 eyes o…

medicine.medical_specialtyBiometryAnterior ChamberScheimpflug principlelaw.inventionCornea03 medical and health sciences0302 clinical medicineOptical coherence tomographyLens thicknesslawOphthalmologymedicineHumansProspective StudiesMathematicsKeratometermedicine.diagnostic_testLimits of agreementSignificant differenceReproducibility of ResultsSensory SystemsAxial Length EyeOphthalmologyInterferometryInterferometrySpain030221 ophthalmology & optometrySurgeryTomography Optical Coherence030217 neurology & neurosurgeryPartial coherenceJournal of Cataract and Refractive Surgery
researchProduct

Determining postoperative anterior chamber depth

2003

Abstract Purpose: To compare measured and calculated postoperative anterior chamber depths (ACDs). Setting: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Vienna, Austria, and Department of Ophthalmology, University of Mainz, Mainz, Germany. Methods: The postoperative ACD was measured in 189 pseudophakic eyes using a laboratory prototype of partial coherence interferometry (PCI). In 6 intraocular lens (IOL) groups, the mean ACD was calculated by ray tracing based on the best-known A-constants of the SRK formulas. In addition, for each IOL type, each measured ACD was compared with a value calculated using the individual spherical equivalent of the postope…

medicine.medical_specialtyBiometryLightPseudophakiaAnterior Chambermedicine.medical_treatmentIntraocular lensSpherical equivalentLens Implantation IntraocularPower calculationsOphthalmologymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryModels TheoreticalCataract surgeryRefractionSensory SystemsOphthalmologyInterferometryPartial coherence interferometryConventional PCISurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Comparison of biometric measurements using partial coherence interferometry and applanation ultrasound

2003

Abstract Purpose To compare and contrast axial length (AL) measurements assessed by ultrasound biometry and optical biometry. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Optical biometry and ultrasound biometry were performed in 360 eyes to measure AL. Results In eyes with a clear-appearing crystalline lens, there was a statistically significant median difference in AL measurements between the 2 methods in eyes with a normal or long length. In eyes with cataract, there was a statistically significant median difference in AL measurements in eyes with a normal or short length. In these cases, optical biometry produced larger readings than ultras…

medicine.medical_specialtyBiometryPseudophakiagenetic structuresBiometricsmedia_common.quotation_subjectmedicine.medical_treatmentEye diseaseIntraocular lensDiagnostic Techniques OphthalmologicalEyeCataractlaw.inventionOptical biometrylawOphthalmologyLens CrystallinemedicineHumansContrast (vision)Ultrasonographymedia_commonbusiness.industryUltrasoundReproducibility of Resultsmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyInterferometryPartial coherence interferometryOptometrySurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Noninvasive diagnostic techniques of port wine stain.

2021

Port-wine stain (PWS) is a benign capillary malformation that most commonly occurs in the head and neck. It is present at birth and progresses over time. It is formed by progressive dilatation of post-capillary venules and is associated with hypertrophy and nodularity with increasing age, leading to cosmetic disfigurement and psychological aggravation. It is caused by genetic mosaicism in GNAQ and GNA11 genes. Histopathology is the gold standard for assessment of PWS but it is invasive and may cause scarring. Inadequate characterization of the lesions may predispose to inadequate treatment protocols as well as higher treatment dosages. Clinical evaluation of treatment efficacy is subjective…

medicine.medical_specialtyCapillary malformationVascular MalformationsPort-Wine StainDermatologyStain030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineOptical coherence tomographyMedicineHumansHemangioma CapillaryMicroscopy Confocalmedicine.diagnostic_testbusiness.industryUltrasoundInfant NewbornPort-wine stainGold standard (test)Laser Doppler velocimetrymedicine.diseaseTristimulus colorimeterTreatment Outcome030220 oncology & carcinogenesisRadiologybusinessJournal of cosmetic dermatologyREFERENCES
researchProduct

Need to consensus for novel findings by optical coherence tomography in patients with age-related macular degeneration

2012

medicine.medical_specialtyConsensusmedicine.diagnostic_testbusiness.industryGeneral MedicineMacular degenerationmedicine.diseaseRetinaMacular DegenerationOphthalmologyOptical coherence tomographyTerminology as TopicOphthalmologyAge relatedmedicineHumansIn patientbusinessTomography Optical CoherenceActa Ophthalmologica
researchProduct

New diagnostic and imaging technologies in dermatology

2021

INTRODUCTION Diagnosis of dermatological disorders is primarily based on clinical examination in combination with histopathology. However, clinical findings alone may not be sufficient for accurate diagnosis and cutaneous biopsies are being associated with morbidity. OBJECTIVE The objective of this article is to review the newer technologies along with their applications, limitation and future prospectus. METHODOLOGY Comprehensive literature search was performed using electronic online databases "PubMed" and "Google Scholar". Articles published in English language were considered for the review. RESULTS In order to improve and/or widen the armamentarium in dermatologic disease diagnosis and…

medicine.medical_specialtyDiagnostic methodsMicroscopy Confocalbusiness.industryEmerging technologies610 MedizinEnglish languageDermatologyDermatologyArtificial Intelligence610 Medical sciencesMedicineHigh frequency ultrasonographyHumansDermatological disordersbusinessTomography Optical CoherenceUltrasonography
researchProduct