Search results for "Collimated light"
showing 6 items of 56 documents
Search for WH production with a light Higgs boson decaying to prompt electron-jets in proton–proton collisions at \(\sqrt {s}=7\) TeV with the ATLAS…
2013
A search is performed for WH production with a light Higgs boson decaying to hidden-sector particles resulting in clusters of collimated electrons, known as electron-jets. The search is performed with 2.04 fb[superscript −1] of data collected in 2011 with the ATLAS detector at the Large Hadron Collider in proton–proton collisions at √s=7 TeV . One event satisfying the signal selection criteria is observed, which is consistent with the expected background rate. Limits on the product of the WH production cross section and the branching ratio of a Higgs boson decaying to prompt electron-jets are calculated as a function of a Higgs boson mass in the range from 100 to 140 GeV.
Analytical model of transit time broadening for two-photon excitation in a three-level ladder and its experimental validation
2012
We revisit transit time broadening for one of the typical experiment designs in molecular spectroscopy, that of a collimated supersonic beam of particles crossing a focused Gaussian laser beam. In particular, we consider a Doppler-free arrangement of a collimated supersonic beam of Na${}_{2}$ molecules crossing two counterpropagating laser beams that excite a two-photon transition in a three-level ladder scheme. We propose an analytical two-level model with a virtual intermediate level to show that the excitation line shape is described by a Voigt profile and provide the validity range of this model with respect to significant experimental parameters. The model also shows that line broadeni…
Optimal recovery of a radiating source with multiple frequencies along one line
2020
We study an inverse problem where an unknown radiating source is observed with collimated detectors along a single line and the medium has a known attenuation. The research is motivated by applications in SPECT and beam hardening. If measurements are carried out with frequencies ranging in an open set, we show that the source density is uniquely determined by these measurements up to averaging over levelsets of the integrated attenuation. This leads to a generalized Laplace transform. We also discuss some numerical approaches and demonstrate the results with several examples.
Collimation of energy in medium-modified QCD jets
2012
The collimation of energy inside medium-modified jets is investigated in the leading logarithmic approximation of QCD. The Dokshitzer-Gribov-Lipatov-Altarelli-Parisi (DGLAP) evolution equations are slightly modified by introducing splitting functions enhanced in the infrared sector. As compared to elementary collisions in the vacuum, the angular distribution of the jet energy is found to broaden in QCD media.
Commissioning and quality assurance procedures for the HDR Valencia skin applicators
2016
The Valencia applicators (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) are cup-shaped tungsten applicators with a flattening filter used to collimate the radiation produced by a high-dose-rate (HDR) 192 Ir source, and provide a homogeneous absorbed dose at a given depth. This beam quality provides a good option for the treatment of skin lesions at shallow depth (3-4 mm). The user must perform commissioning and periodic testing of these applicators to guarantee the proper and safe delivery of the intended absorbed dose, as recommended in the standards in radiation oncology. In this study, based on AAPM and GEC-ESTRO guidelines for brachytherapy units and our experience, a set …
Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses
2018
In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…