Search results for "Colori"
showing 10 items of 281 documents
Comparison of three different staining methods for the assessment of epididymal red deer sperm morphometry by computerized analysis with ISAS®
2005
When collection of ejaculated sperm samples is not possible, as is the case with wild species, the epididymides of sacrificed wild males become the only possible source of spermatozoa. Mature cauda epididymal spermatozoa display characteristics similar to those of ejaculated sperm cells. The present work proposes a sperm staining technique suitable for the morphometric evaluation of red deer epididymal sperm using a new computerized system. Epididymides from wild animals were extracted no later than 2 h post mortem. After epididymal sectioning, sperm samples were collected, cooled to and equilibrated at 5 °C, and frozen in liquid nitrogen. Before staining, sperm samples were thawed for 20 s…
Vessel painting of the microcirculation using fluorescent lipophilic tracers
2005
Flexible approaches to defining microvessel morphometry are useful in the study of both acute and chronic structural changes of the microcirculation. In this report, we examined the utility of the intravascular infusion of lipophilic carbocyanine tracers in the structural assessment of the retina, skin, lung, and colon microcirculation. The microvessel labeling technique, here termed fluorescent vessel painting, involved the intravascular injection of sulfonated lipophilic carbocyanine tracers. The utility of vessel painting in morphometry was assessed using morphometric comparisons with corrosion casting and 2-dimensional and 3-dimensional scanning electron microscopy. The comparisons demo…
Discriminant ability for caries risk of modified colorimetric tests.
2010
Objetive: The aim of this study was to evaluate the relationship between the caries risk in children over a two-year period and their baseline caries status, salivary levels of mutans streptococci and lactobacilli, and results of the Alban test and modifications thereof using different substrates. Study design: Ninety-five children aged 6-7 were examined in Granada (southern Spain) for dental caries at baseline and every six months. Stimulated saliva was sampled and inoculated in 7 colorimetric tests based on Snyder's medium with different sugars and polyalcohols. A mutans streptococci and lactobacilli count was performed (Dentocult SM strip® and Dentocult LB®). Caries risk proportions were…
A Microassay for Measuring Glycogen in 96-Well-Cultured Cells
1996
Abstract This study describes a rapid, sensitive, and automated spectrophotometric enzymatic microassay that measures the intracellular glycogen of primary cultured hepatocytes and other cultured cells in 96-well plates and can be adapted for other samples that are transferred to these plates. The procedure involves in situ disruption of cells, followed by hydrolysis of glycogen into glucosyl units by fungal glucoamylase (exo-1,4-α- D -glucosidase, EC 3.2.1.3), and glucose determination with the glucose oxidase colorimetric method. The color intensity can be measured in conventional ELISA readers, and the data can be fed to an on-line computer for rapid processing. The advantages of this me…
The accuracy of flexible spectral imaging colour enhancement for the diagnosis of gastric intestinal metaplasia
2014
Background Targeting biopsies on the basis of visual recognition of mucosal changes in the stomach instead of the currently accepted random biopsy sampling may be attractive. Aim The aim of this study was to evaluate the accuracy of endoscopic findings using flexible spectral imaging colour enhancement (FICE) for intestinal metaplasia (IM) in the gastric mucosa. Methods A consecutive cohort of 126 individuals aged over 50 years (27% men) was subjected to upper endoscopy using FICE. Histological assessment (per patient and per biopsy) was considered the gold standard to accuracy estimates. Results Histological assessment revealed IM in 50% of the individuals [OLGIM (operative link on gastric…
Chromoendoscopy and narrow-band imaging compared with high-resolution magnification endoscopy in Barrett's esophagus.
2008
Background & Aims: The aim of this study was to compare magnified still images obtained with high-resolution white light endoscopy, indigo carmine chromoendoscopy, acetic acid chromoendoscopy, and narrow-band imaging to determine the best technique for use in Barrett's esophagus. Methods: We obtained magnified images from 22 areas with the 4 aforementioned techniques. Seven endoscopists with no specific expertise in Barretes esophagus or advanced imaging techniques and 5 international experts in this field evaluated these 22 areas for overall image quality, mucosal image quality, and vascular image quality. In addition, the regularity of mucosal and vascular patterns and the presence of abn…
Pathological Evaluation of Mesocolic Resection Quality and Ex Vivo Methylene Blue Injection
2012
BACKGROUND: Although the National Quality Forum has endorsed the harvest of ≥12 lymph nodes as a standard quality indicator for colon cancer surgery, this minimum quantity is not reached in many centers. OBJECTIVE: The aim of this study was to assess the impact of the implementation of a mesocolon evaluation pathological protocol and ex vivo arterial methylene blue injection on the number of nodes harvested after colon cancer resection. DESIGN: A prospective series was compared with a historical group. SETTINGS: This study was conducted by a specialized colorectal multidisciplinary team at a tertiary teaching hospital. PATIENTS: From June 2009 to December 2009, all the specimens after colon…
A New Environmentally-Friendly Colorimetric Probe for Formaldehyde Gas Detection under Real Conditions
2018
[EN] A new environmentally-friendly, simple, selective and sensitive probe for detecting formaldehyde, based on naturally-occurring compounds, through either colorimetric or fluorescence changes, is described. The probe is able to detect formaldehyde in both solution and the gas phase with limits of detection of 0.24 mM and 0.7 ppm, respectively. The probe has been tested to study formaldehyde emission in contaminated real atmospheres. The supported probe is easy to use and to dispose, and is safe and suitable as an individual chemodosimeter.
Snapshot RGB mapping of skin melanin and hemoglobin.
2015
The concept of snapshot red-green-blue (RGB) multispectral imaging was applied for skin chromophore mapping. Three monochromatic spectral images have been extracted from a single RGB image dataset at simultaneous illumination of skin by 473-, 532-, and 659-nm laser lines. The spectral images were further transformed into distribution maps of skin melanin, oxyhemoglobin, and deoxyhemoglobin, related to pigmented and vascular skin malformations. The performance and clinical potential of the proposed technique are discussed
Energy and charge transfer in nanoscale hybrid materials.
2015
Hybrid materials composed of colloidal semiconductor quantum dots and π-conjugated organic molecules and polymers have attracted continuous interest in recent years, because they may find applications in bio-sensing, photodetection, and photovoltaics. Fundamental processes occurring in these nanohybrids are light absorption and emission as well as energy and/or charge transfer between the components. For future applications it is mandatory to understand, control, and optimize the wide parameter space with respect to chemical assembly and the desired photophysical properties. Accordingly, different approaches to tackle this issue are described here. Simple organic dye molecules (Dye)/quantum…