Search results for "Computer Hardware"

showing 10 items of 378 documents

The NA48 event-building PC farm

2003

The NA48 experiment at the CERN SPS aims to measure the parameter $\Re(\epsilon'/ \epsilon)$ of direct CP violation in the neutral kaon system with an accuracy of $2 \times 10^{-4}$. Based on the requirements of: \\\\ * high event rates (up to 10 kHz) with negligible dead time;\\ * support for a variety of detectors with very wide variation in the number of readout channels;\\ * data rates of up to 150 MByte/s sustained over the beam burst;\\ * level-3 filtering and remote data logging in the CERN computer center; \\\\ the collaboration has designed and built a modular pipelined data flow system with 40 MHz sampling rate. The architecture combines custom-designed components with commerciall…

Nuclear and High Energy PhysicsCost effectivenessComputer sciencebusiness.industryPentiumNA48 experimentDead timeTerabyteData flow diagramData acquisitionNuclear Energy and EngineeringData loggerDetectors and Experimental TechniquesElectrical and Electronic EngineeringbusinessComputer hardwareIEEE Transactions on Nuclear Science
researchProduct

Conceptual design and infrastructure for the installation of the first AGATA sub-array at LNL

2011

WOS: 000295765100014

Nuclear and High Energy PhysicsDANTE Heavy-ion DetectorPhysics::Instrumentation and DetectorsHELENA multiplicity filter01 natural sciences7. Clean energyParticle detectorNuclear physicsPRISMA spectrometerConceptual design0103 physical sciences[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Nuclear Experiment010306 general physicsGamma detectionInstrumentationTRACE SI detectorPhysicsSpectrometer010308 nuclear & particles physicsbusiness.industrySemiconductor detectorCologne plungerAGATAAGATADANTE heavy-ion-detectorbusinessComputer hardwareNuclear Instruments and Methods in Physics Research
researchProduct

Development of the Optical Multiplexer Board Prototype for Data Acquisition in the TileCal System

2006

This paper describes the development of the optical multiplexer board (OMB), also known as PreROD board, for the TileCal readout system in the ATLAS experiment. The aim of this board is to overcome the problems that may arise in the integrity of data due to radiation effects. The solution adopted has been to add redundancy to data transmission and so two optical fibers with the same data come out from the detector front end boards. The OMB has to decide in real time which fiber, eventually, carries data with no errors switching it to the output link connected to the read out driver (ROD) motherboard where data processing takes place. Besides, the board may be also used as a data injector fo…

Nuclear and High Energy PhysicsEngineeringMotherboardFirmwarebusiness.industrycomputer.software_genreMultiplexerFront and back endsData acquisitionNuclear Energy and EngineeringCyclic redundancy checkRedundancy (engineering)Electronic engineeringElectrical and Electronic EngineeringbusinesscomputerComputer hardwareData transmissionIEEE Transactions on Nuclear Science
researchProduct

From the Reference SEU Monitor to the Technology Demonstration Module On-Board PROBA-II

2008

The reference SEU Monitor system designed and presented in 2005 (R. H. SOslashrensen, F.-X. Guerre, and A. Roseng ldquoDesign, testing and calibration of a reference SEU monitor system,rdquo in Proc. RADECS, 2005, pp. B3-1-B3-7) has now been used by many researchers at many radiation test sites and has provided valuable calibration data in support of numerous projects. As some of these findings and results give new insight into improved inter-facility calibrations and provide additional inputs into ongoing SEE research, a few of the more interesting cases are presented. Furthermore the dasiadetector elementpsila, the Atmel AT60142F SRAM, now in a hybrid configuration, will form the key dete…

Nuclear and High Energy PhysicsEngineeringbusiness.industryDetectorOn boardRadiation testingNuclear Energy and EngineeringSingle event upsetCalibrationKey (cryptography)Electronic engineeringSatelliteStatic random-access memoryElectrical and Electronic EngineeringbusinessComputer hardwareIEEE Transactions on Nuclear Science
researchProduct

Optical Link Card Design for the Phase II Upgrade of TileCal Experiment

2011

This paper presents the design of an optical link card developed in the frame of the R&D activities for the phase 2 upgrade of the TileCal experiment. This board, that is part of the evaluation of different technologies for the final choice in the next years, is designed as a mezzanine that can work independently or be plugged in the optical multiplexer board of the TileCal backend electronics. It includes two SNAP 12 optical connectors able to transmit and receive up to 75 Gb/s and one SFP optical connector for lower speeds and compatibility with existing hardware as the read out driver. All processing is done in a Stratix II GX field-programmable gate array (FPGA). Details are given on th…

Nuclear and High Energy PhysicsEngineeringbusiness.industryFirmwareOptical linkElectrical engineeringPower integritycomputer.software_genreMultiplexerUpgradeNuclear Energy and EngineeringGate arrayStratixElectrical and Electronic EngineeringbusinessField-programmable gate arraycomputerComputer hardwareIEEE Transactions on Nuclear Science
researchProduct

The Argo YBJ daq system and the GRID based data transfer

2008

The Argo-YBJ experiment has now reached itsfinal design configuration. The detector system consists of a fullcoverage array (about 5800 square meters) of Resistive PlateChambers (RPCs). The throughput depends on the trigger rateand threshold. The DAQ system must be able to sustain a max-imum transfer rate of the order of 15 MB/s and a high peakdata flow. Data are read out using a typical front-end acquisitionchain built around a custom bus. Specialized electronics have beendesigned and dedicated software has been written to perform thistask. Data are sent to the online farm through a switch exploitinga gigabit ethernet protocol. A solution to transfer data from theYBJ laboratory to the labo…

Nuclear and High Energy PhysicsEngineeringbusiness.industryGigabit Ethernetcomputer.software_genreGridData flow diagramData acquisitionNuclear Energy and EngineeringGrid computingNuclear electronicsData acquisition data mover GRID RPCElectrical and Electronic EngineeringbusinessThroughput (business)computerComputer hardwareData transmission
researchProduct

AGATA-Advanced GAmma Tracking Array

2012

WOS: 000300864200005

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsPulse-shape and gamma-ray tracking algorithmsFOS: Physical sciencesSemiconductor detector performance and simulationsIntegrated circuit[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Tracking (particle physics)gamma-Ray tracking01 natural sciencesPulse-shape and γ-ray tracking algorithmslaw.inventionData acquisitionlaw0103 physical sciencesddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Nuclear Experiment (nucl-ex)010306 general physicsγ-Ray spectroscopyNuclear ExperimentInstrumentationDigital signal processingEvent reconstructiongamma-Ray spectroscopyPhysicssezeleSpectrometerSpectrometers010308 nuclear & particles physicsbusiness.industryDetectorAGATA Digital signals HPGe detectors Pulse-shape Ray trackingHPGe detectorsAlgorithms Crystals Germanium Semiconductor detectors Signal processing Spectrometry Tracking (position)γ-Ray trackingInstrumentation and Detectors (physics.ins-det)Digital signal processingAGATAFísica nuclearbusinessAGATAComputer hardware
researchProduct

Low-cost, portable open-source gas monitoring device based on chemosensory technology

2015

[EN] We report herein the construction of an electronic device to perform the real-time digitalization of the color state of the optical chemosensors used in the detection of dangerous gases. To construct the device, we used open-source modular electronics, such as Arduino and Sparkfun components, as well as free and open-source software (FOSS). The basic principle of the operation of this device is the continuous color measurement of a chemosensor-doped sensing film, whose color changes in the presence of a specific gas. The chemosensor-sensing film can be prepared by using any of the widely available chemosensors for the desired gas. Color measurement is taken by two TCS230 color sensor I…

Open-sourceLiquid-crystal displayComputer sciencebusiness.industryApplied MathematicsColorSerial portChemosensorMonitorUSBModular designlaw.inventionMicrocontrollerGaslawArduinoArduinoGas detectorElectronicsbusinessInstrumentationEngineering (miscellaneous)Computer hardwareSensorMeasurement Science and Technology
researchProduct

Design and implementation of a portable fNIRS embedded system

2015

We report on the design, development and operation of a portable, low cost, battery-operated, multi-channel, functional Near Infrared Spectroscopy embedded system, hosting up to 64 optical sources and 128 Silicon PhotoMultiplier optical detectors. The system is realized as a scalable architecture, whose elementary leaf consists of a probe board provided with 16 SiPMs, 4 couples of bi-color LED, and a temperature sensor, built on a flexible stand. The hardware structure is very versatile because it is possible to handle both the switching time of the LED and the acquisition of the photodetectors, via an ARM based microcontroller.

Optical detectorsbusiness.industryComputer sciencePhotodetectorInfrared spectroscopyScalable architectureSilicon photomultiplierSettore ING-INF/01 - ElettronicaIndustrial and Manufacturing EngineeringSwitching timeMicrocontrollerSilicon photomultiplierEmbedded systemFunctional near-infrared spectroscopyFNIRS embedded systembusinessInfrared spectroscopyComputer hardware
researchProduct

Multi-spectral photoplethysmography biosensor

2011

A photoplethysmography (PPG) signal can provide very useful information about a subject's hemodynamic status in a hospital or home environment. A newly developed portable multi-spectral photoplethysmography device has been used for studies of 11 healthy subjects. The developed optical fiber biosensor comprises one multi-wavelength laser diode (405nm, 660nm and 780nm) and a single photodiode with multi-channel signal output processing and built in Li-ion accumulator; special software was created for visualization and measuring of the MS-PPG signals. ARM7TDMI-S LPC2148, NXP (founded by Philips) 32 bit processor with clock frequency of 60 MHz performs measurement and analysis of the signal.

Optical fiberLaser diodebusiness.industryComputer scienceSignalPhotodiodelaw.inventionOpticslawPhotoplethysmogramAccumulator (computing)businessBiosensorComputer hardwareSPIE Proceedings
researchProduct