Search results for "Computer Science"
showing 10 items of 22367 documents
Adaptation and Refinement of Validated Risk Screening Tools in the Spanish Healthcare System
2013
Abstract The aim of this study is to develop a tool to screen elders at risk of hospital readmissions adapted to Spanish target population. The development of this new tool is based on the validated instrument The Community Assessment Risk Screen – CARS –, which is being applied in a sample of 1.000 older patients. The adaptation and refinement of CARS is being carried out through the compilation of new potential variables from primary care clinicians to predict patients at risk of readmissions. The introduction of this new instrument adapted to Spanish target population will provide a potential tool to identify prematurel y patients at risk of hospital readmissions.
Unsupervised Numerical Characterization in Determining the Borders of Malignant Skin Tumors from Spectral Imagery
2021
For accurate removal of malignant skin tumors, it is crucial to assure the complete removal of the lesions. In the case of certain ill-defined tumors, it is clinically challenging to see the true borders of the tumor. In this paper, we introduce several computationally efficient approaches based on spectral imaging to guide clinicians in delineating tumor borders. First, we present algorithms that can be used effectively with simulated skin reflectance data. By using simulated data, we gain detailed information about the sensitivity of the different approaches and how variables defined by algorithms act in the skin model. Second, we demonstrate the performance of the algorithms with spectra…
ECG Analysis for Ventricular Fibrillation Detection Using a Boltzmann Network
2015
Arrhythmias consist on electrical alterations in the heart beat control. They can be identified by means of surface ECG leads. The main goal of this work is to provide a signal classification based on ECG signal waveform in the time-frequency domain especially targeted to Ventricular Fibrillation detection. The use of a classifier based on a Boltzmann network is proposed. However, a previous signal preprocessing is also required so that the Boltzmann network is fed with the appropriate data. In this case, an R-wave detector is used; after that, the Pseudo Wigner-Ville time-frequency distribution is obtained. This distribution is used to train and test the network, which handles it as an ima…
Stereoscopic Viewing Enhances Visually Induced Motion Sickness but Sound Does Not
2012
Optic flow in visual displays or virtual environments often induces motion sickness (MS). We conducted two studies to analyze the effects of stereopsis, background sound, and realism (video vs. simulation) on the severity of MS and related feelings of immersion and vection. In Experiment 1, 79 participants watched either a 15-min-long video clip taken during a real roller coaster ride, or a precise simulation of the same ride. Additionally, half of the participants watched the movie in 2D, and the other half in 3D. MS was measured using the Simulator Sickness Questionnaire (SSQ) and the Fast Motion Sickness Scale (FMS). Results showed a significant interaction for both variables, indicatin…
Läßt sich das sonomorphologische Lymphknotenstaging bei Kopf-Hals-Karzinomen automatisieren?
2000
OBJECTIVES B-scan ultrasound imaging is an obligatory examination of great clinical relevance in patients with head and neck cancer. The procedure, however, is dependent on an experienced examiner and thus requires higher personal resources than other examination techniques. In addition, its subjective character leads to possible deficits in reliability and objectivity. Established sonomorphologic criteria (echo-contour, echo-density, echo-structure, boundary) should therefore be matched to the findings of computer aided sonomorphometry. METHOD 200 sonographic images of the cervical region of patients with oral carcinoma were analysed semi- and fully automatically as well as interactively b…
PO-55 The persistence of residual vein thrombosis, after an episode of deep vein thrombosis, and the risk of new overt cancer
2007
Video-assisted surgery: suggestions for failure prevention in laparoscopic cholecystectomy
2014
Background: Surgery differs from other medical specialties in its execution. It is often complex and includes considerable individual variations. Observing problems in operating theatres (OT) allows for the identification of system failures which should be defined for learning purposes to increase patient safety and enhance general safety culture within hospital organizations. This study evaluates a common video-assisted surgical procedure, laparoscopic cholecystectomy (LC) through failure analysis. The profile of the LC procedure and failure sources is presented. Methods: Data consisted video-observations and interviews concerning twelve LC operations performed at a day surgery unit. All o…
Critical Appraisal of Scientific Articles
2009
Despite the increasing number of scientific publications, many physicians find themselves with less and less time to read what others have written. Selection, reading, and critical appraisal of publications is, however, necessary to stay up to date in one’s field. This is also demanded by the precepts of evidence-based medicine (1, 2). Besides the medical content of a publication, its interpretation and evaluation also require understanding of the statistical methodology. Sadly, not even in science are all terms always used correctly. The word "significance," for example, has been overused because significant (or positive) results are easier to get published (3, 4). The aim of this article …
SEssion 06 Morphogenesisin vitro
1994
Spectral decomposition of RR-variability obtained by an open loop parametric model for the diagnosis of neuromediate syncope
2002
The role of the cardiovascular regulatory mechanism in patients with neuromediate syncope (NS) is poorly understood. The aim of this study was to accomplish continuous non-invasive analysis of the baroreflex mechanism in patients during a head-tip tilt-table test (HTT) using an open-loop autoregressive model with exogenous input. The model describes the causal dependence of the RR interval on the systolic arterial pressure (SAP) variability. Thus, RR variability results as the linear composition of SAP-dependent (Pdep) and SAP-independent parts of the RR power (P). Further, the model allows the estimation of the baroreflex gain using the modulus of the transfer function (G) from SAP to RR i…