A granulometric analysis of specular microscopy images of human corneal endothelia
2005
The inner layer of the human cornea, called the corneal endothelium, plays an important role in the maintenance of corneal transparency. Specular microscopy is the most widely used technique to study the corneal endothelium in vivo. Improvements in technology have allowed us to obtain good quality specular images, but the detection and quantification of small size-shape cell changes is not obvious, specially when the physician wants to evaluate endothelial cell changes after some surgical procedures. This paper proposes a methodology to analyze specular microscopy images. Every corneal endothelium is described by means of different cumulative distribution functions or some moments (mean, st…
Classifying human endothelial cells based on individual granulometric size distributions
2002
Abstract This paper presents an application to a medical problem of methods of shape analysis based on mathematical morphology. The medical problem consists on the detection of abnormalities in the corneal endothelium, a tissue composed by quasi-planar cells of ideally regular hexagonal shape. Images of this tissue are taken by a specular microscope and used to evaluate the corneal endothelium status. Up to now, cell density, hexagonality and an analysis of cell areas are the usual descriptors of a corneal endothelium. These parameters are not sensitive enough to detect subtle lesions. What this paper proposes is an analysis based on granulometries, which are size-shape descriptors widely u…
Set Descriptors for Visual Evaluation of Human Corneal Endothelia
2001
Images of corneal endothelium obtained from specular microscopy are of great importance in the evaluation of the corneal endothelium status. Several commercial tools provide some numerical descriptors to characterize these images in terms of cell density, hexagonality, and some descriptive statistics of the cell areas. However, it is a too simple analysis that only detects severe abnormal endothelia with many irregular and large cells. Detection of subtle abnormalities needs a more refined analysis. This paper proposes a shape-size descriptor based on some modified versions of the geometric covariogram. This descriptor is presented as a valid alternative to the classical analysis that provi…
Structural modelling and mechanical tests supporting the design of the ATHENA X-IFU thermal filters and WFI optical blocking filter
2018
Copyright 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. ATHENA is a Large high energy astrophysics space mission selected by ESA in the Cosmic Vision 2015-2025 Science Program. It will be equipped with two interchangeable focal plane detectors: the X-Ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). Both detectors require x-ray transparent filters to fully exploit their sensitivity. In order to maximize the X-ray tra…
Nonlinear dynamical model of Costas loop and an approach to the analysis of its stability in the large
2015
The analysis of the stability and numerical simulation of Costas loop circuits for high-frequency signals is a challenging task. The problem lies in the fact that it is necessary to simultaneously observe very fast time scale of the input signals and slow time scale of phase difference between the input signals. To overcome this difficult situation it is possible, following the approach presented in the classical works of Gardner and Viterbi, to construct a mathematical model of Costas loop, in which only slow time change of signal?s phases and frequencies is considered. Such a construction, in turn, requires the computation of phase detector characteristic, depending on the waveforms of th…
High-order modes in cavity-resonator-integrated guided-mode resonance filters (CRIGFs)
2015
International audience; Cavity-resonator-integrated guided-mode resonance filters (CRIGFs) are optical filters based on weak coupling by a grating between a free-space propagating optical mode and a guided mode, like guided-mode resonance filters (GMRFs). As compared to GMRFs they offer narrowband reflection with small aperture and high angular acceptance. We report experimental characterization and theoretical modeling of unexpected high-order reflected modes in such devices. Using coupled-mode modeling and moiré analysis we provide physical insight on key mechanisms ruling CRIGF properties. This model could serve as a simple and efficient framework to design new reflectors with tailored s…
Measuring Spatiotemporal Dependencies in Bivariate Temporal Random Sets with Applications to Cell Biology
2008
Analyzing spatiotemporal dependencies between different types of events is highly relevant to many biological phenomena (e.g., signaling and trafficking), especially as advances in probes and microscopy have facilitated the imaging of dynamic processes in living cells. For many types of events, the segmented areas can overlap spatially and temporally, forming random clumps. In this paper, we model the binary image sequences of two different event types as a realization of a bivariate temporal random set and propose a nonparametric approach to quantify spatial and spatiotemporal interrelations using the pair correlation, cross-covariance, and the Ripley K functions. Based on these summary st…
Vector anisotropic filter for multispectral image denoising
2015
In this paper, we propose an approach to extend the application of anisotropic Gaussian filtering for multi- spectral image denoising. We study the case of images corrupted with additive Gaussian noise and use sparse matrix transform for noise covariance matrix estimation. Specifically we show that if an image has a low local variability, we can make the assumption that in the noisy image, the local variability originates from the noise variance only. We apply the proposed approach for the denoising of multispectral images corrupted by noise and compare the proposed method with some existing methods. Results demonstrate an improvement in the denoising performance.
Linear transform for simultaneous diagonalization of covariance and perceptual metric matrix in image coding
2003
Two types ofredundancies are contained in images: statistical redundancy and psychovisual redundancy. Image representation techniques for image coding should remove both redundancies in order to obtain good results. In order to establish an appropriate representation, the standard approach to transform coding only considers the statistical redundancy, whereas the psychovisual factors are introduced after the selection ofthe representation as a simple scalar weighting in the transform domain. In this work, we take into account the psychovisual factors in the de8nition of the representation together with the statistical factors, by means of the perceptual metric and the covariance matrix, res…
The TES-based cryogenic anticoincidence detector for IXO: First results from large area prototypes
2010
The technique which combines high resolution spectroscopy with imaging capability is a powerful tool to extract fundamental information in X-ray Astrophysics and Cosmology. TES (Transition Edge Sensors)-based microcalorimeters match at best the requirements for doing fine spectroscopy and imaging of both bright (high count rate) and faint (poor signal-to-noise ratio) sources. For this reason they are considered among the most promising detectors for the next high energy space missions and are being developed for use on the focal plane of the IXO (International X-ray Observatory) mission. In order to achieve the required signal-to-noise ratio for faint or diffuse sources it is necessary to r…