Search results for "Computer vision"
showing 10 items of 2353 documents
Angiocardiographic digital still images compressed via irreversible methods: concepts and experiments.
1997
Abstract We defined, implemented and tested two new methods for irreversible compression of angiocardiographic still images: brightness error limitation (BEL) and pseudo-gradient adaptive brightness and contrast error limitation (PABCEL). The scan path used to compress the digital images is based on the Peano–Hilbert plane-filling curve. The compression methods limit, for each pixel, the brightness errors introduced when approximating the original image (i.e. the difference between the values of corresponding pixels as grey levels). Additional limitations are imposed to the contrast error observed when considering along the scan path consecutive pixels of both the original and the reconstru…
Corresponding-pair procedure: a new approach to simulation of dichromatic color perception.
2004
The dichromatic color appearance of a chromatic stimulus T can be described if a stimulus S is found that verifies that a normal observer experiences the same sensation viewing S as a dichromat viewing T. If dichromatic and normal versions of the same color vision model are available, S can be computed by applying the inverse of the normal model to the descriptors of T obtained with the dichromatic model. We give analytical form to this algorithm, which we call the corresponding-pair procedure. The analytical form highlights the requisites that a color vision model must verify for this procedure to be used. To show the capabilities of the method, we apply the algorithm to different color vi…
Lit environments quality: A software for the analysis of luminance maps obtained with the HDR imaging technique
2013
Abstract Energy performance of lighting systems has assumed a significant role in the assessment of buildings’ consumptions and consequently lighting design is aimed to reduce installed power but at the same time to achieve an excellent lighting quality both for visual and health purposes. Lighting design is nowadays essentially based on illuminance values on visual tasks and surrounding areas, but today designers’ and researchers’ interest is focused on the analysis of luminance maps obtained through video luminance meters or with numeric simulation tools. Luminance maps availability focus the attention on a more accurate study of the light reaching the eyes (luminance), rather than on the…
Brightness and contrast do not affect visually induced motion sickness in a passively-flown fixed-base flight simulator
2016
Abstract Background Visually Induced Motion Sickness (VIMS) or simulator sickness is often elicited by a visual stimulus that lacks the appropriate vestibular or proprioceptive feedback. In this study, we chose to investigate the effects of brightness and contrast of the visual scene on VIMS. Hypothesis We hypothesized that visual environments differing in brightness or contrast would differentially induce VIMS. The symptoms of VIMS should be most severe for the combination of high brightness and high contrast and conversely lowest for the low brightness and low contrast condition. Methods 33 healthy subjects were tested in a fixed-base flight simulator. Each subject flew in four consecutiv…
Cover Feature: Palladium‐Catalyzed Electrophilic C–H‐Bond Fluorination: Mechanistic Overview and Supporting Evidence (Eur. J. Org. Chem. 2‐3/2019)
2018
A Fuzzy Logic C-Means Clustering Algorithm to Enhance Microcalcifications Clusters in Digital Mammograms
2011
The detection of microcalcifications is a hard task, since they are quite small and often poorly contrasted against the background of images. The Computer Aided Detection (CAD) systems could be very useful for breast cancer control. In this paper, we report a method to enhance microcalcifications cluster in digital mammograms. A Fuzzy Logic clustering algorithm with a set of features is used for clustering microcalcifications. The method described was tested on simulated clusters of microcalcifications, so that the location of the cluster within the breast and the exact number of microcalcifications is known.
Index-based triangulation method for efficient generation of large three-dimensional ultrasonic C-scans
2018
The demand for high-speed ultrasonic scanning of large and complex components is driven by a desire to reduce production bottlenecks during the non-destructive evaluation (NDE) of critical parts. Emerging systems (including robotic inspection) allow for the collection of large volumes of data in short time spans, compared to existing inspection systems. To maximise throughput, it is crucial that the reconstructed inspection datasets are generated and evaluated rapidly without loss of detail. This requires new data visualisation and analysis tools capable of mapping complex geometries while guaranteeing full coverage. This paper presents an entirely new approach for the visualisation of thre…
Color choice behavior in cats and the effect of changes in the color of the illuminant.
1993
3D segmentation of abdominal aorta from CT-scan and MR images
2012
International audience; We designed a generic method for segmenting the aneurismal sac of an abdominal aortic aneurysm (AAA) both from multi-slice MR and CT-scan examinations. It is a semi-automatic method requiring little human intervention and based on graph cut theory to segment the lumen interface and the aortic wall of AAAs. Our segmentation method works independently on MRI and CT-scan volumes and has been tested on a 44 patient dataset and 10 synthetic images. Segmentation and maximum diameter estimation were compared to manual tracing from 4 experts. An inter-observer study was performed in order to measure the variability range of a human observer. Based on three metrics (the maxim…
Comparison among different rainfall energy harvesting structures
2018
In this paper, an experimental comparison between different rainfall harvesting devices through the study of the electrical rectifying circuit is proposed. In more detail, three harvesting structures are considered: the cantilever, the bridge and the floating circle. Different waveforms were acquired and discussed. The processed data were compared in order to suggest the best choice for the rectifying circuit, from the simplest one to that most frequently endorsed in the technical literature.