Search results for "Computer-assisted"
showing 10 items of 1186 documents
Automated classification of focal breast lesions according to S-detect: validation and role as a clinical and teaching tool
2018
Abstract PURPOSE: To assess the diagnostic performance and the potential as a teaching tool of S-detect in the assessment of focal breast lesions. METHODS: 61 patients (age 21-84 years) with benign breast lesions in follow-up or candidate to pathological sampling or with suspicious lesions candidate to biopsy were enrolled. The study was based on a prospective and on a retrospective phase. In the prospective phase, after completion of baseline US by an experienced breast radiologist and S-detect assessment, 5 operators with different experience and dedication to breast radiology performed elastographic exams. In the retrospective phase, the 5 operators performed a retrospective assessment a…
Small bowel motility: relationship between smooth muscle contraction and electroenterogram signal.
2000
A study is made to correlate the electrical and mechanical activity of the smooth muscle of the small bowel. Bioelectrical signal recording from the intestinal serosa (electroenterogram) comprises a slow wave (SW) and spike burst (SB), though only the latter reflects intestinal pressure. The electroenterogram and smooth muscle pressure are simultaneously recorded in the canine small bowel. Spectral and time series analysis of the electroenterogram are performed to establish those electrical parameters that best reflect intestinal pressure. The results reveal an underlying correlation between the estimated parameters of electrical activity and smooth muscle pressure. In addition, parameters …
Multi-system machine translation using online APIs for English-Latvian
2015
This paper describes a hybrid machine translation (HMT) system that employs several online MT system application program interfaces (APIs) forming a MultiSystem Machine Translation (MSMT) approach. The goal is to improve the automated translation of English – Latvian texts over each of the individual MT APIs. The selection of the best hypothesis translation is done by calculating the perplexity for each hypothesis. Experiment results show a slight improvement of BLEU score and WER (word error rate).
K-Translate - Interactive Multi-system Machine Translation
2016
The tool described in this article has been designed to help machine translation (MT) researchers to combine and evaluate various MT engine outputs through a web-based graphical user interface using syntactic analysis and language modelling. The tool supports user provided translations as well as translations from popular online MT system application program interfaces (APIs). The selection of the best translation hypothesis is done by calculating the perplexity for each hypothesis. The evaluation panel provides sentence tree graphs and chunk statistics. The result is a syntax-based multi-system translation tool that shows an improvement of BLEU scores compared to the best individual baseli…
Enhanced chemiluminescent determination of chloramphenicol and related nitro compounds by ‘on-line’ photochemical reaction
2000
The viability of tandem photochemical reaction-chemiluminescence detection was studied for a heterogeneous family of nitro compounds using chloramphenicol as a test substance. The 'on-line' chemical photodegradation of chloramphenicol was performed in a flow injection assembly by using a photoreactor consisting of a 725 cm x 0.5 mm id piece of PTFE tubing coiled around an 8 W low-pressure mercury lamp. Photodegraded chloramphenicol was detected by oxidizing photo-fragments from the parent compound and their subsequent reaction with a luminol-Co(II) system. The calibration graph was linear up to 3 x 10(-5) mol l-1 chloramphenicol, the limit of detection was 3 x 10(-9) mol l-1, the relative s…
Megakaryocytic features useful for the diagnosis of myeloproliferative disorders can be obtained by a novel unsupervised software analysis
2006
An unsupervised method for megakaryocyte detection and analysis is proposed, in order to validate supplementary tools which can be of help in supporting the pathologist in the classification of Philadelphia negative chronic myeloproliferative disorders with thrombocytosis. The experiment was conducted on high power magnification photomicrographs taken from hematoxylin-and-eosin 3 µm thick sections of formalin fixed, paraffin embedded bone marrow biopsies from patients with reactive thrombocytosis or chronic myeloproliferative disorders. Each megakaryocyte has been isolated in the photos through an image segmentation process, mainly based on mathematical morphology and wavelet analysis. A se…
Wearable, Fiber-less, Multi-Channel System for Continuous Wave Functional Near Infrared Spectroscopy Based on Silicon Photomultipliers Detectors and …
2019
Development and in-vivo validation of a Continuous Wave (CW) functional Near Infrared Spectroscopy (fNIRS) system is presented. The system is wearable, fiber-less, multi-channel (16×16, 256 channels) and expandable and it relies on silicon photomultipliers (SiPMs) for light detection. SiPMs are inexpensive, low voltage and resilient semiconductor light detectors, whose performances are analogous to photomultiplier tubes (PMTs). The advantage of SiPMs with respect to PMTs is that they allow direct contact with the scalp and avoidance of optical fibers. In fact, the coupling of SiPMs and light emitting diodes (LEDs) allows the transfer of the analog signals to and from the scalp through thin …
Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations.
2009
Current dosimetry protocols require geometrical reference conditions for the determination of absorbed dose in external radiotherapy. Whenever these geometrical conditions cannot be maintained the application of additional corrections becomes necessary, in principle. The current DIN6800-2 protocol includes a corresponding factor k(NR), but numerical values are lacking and no definite information about the magnitude of this correction is available yet. This study presents Monte-Carlo based calculations within the 6 MV-X photon field of a linear accelerator for a common used ion chamber (PTW31010) employing the EGSnrc code system. The linear accelerator model was matched to measurements, show…
The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.
2014
Abstract The mixed neutron–photon beam of FiR 1 reactor is used for boron–neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple b…
Phantom size in brachytherapy source dosimetric studies
2004
An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newly-developed 3-D correction algorithms are based on physics data that are obtained under full scatter conditions, i.e., assumed infinite phantom size. One can then assume that reference dose distributions in source dosimetry for photon brachytherapy should use an unbounded phantom size rather than phantom-like dimensions. Our aim in this paper is to study the effect of phantom s…