Search results for "Cone-beam computed tomography"

showing 10 items of 90 documents

Editorial 1/2018

2017

Cone beam computed tomographyInformation retrievalbusiness.industry030503 health policy & servicesMEDLINE030206 dentistryGeneral MedicineCone-Beam Computed Tomography03 medical and health sciencesEditorial0302 clinical medicineText miningOtorhinolaryngologyHumansMedicineRadiology Nuclear Medicine and imagingMouth Diseases0305 other medical sciencebusinessGeneral DentistryDentomaxillofacial Radiology
researchProduct

Mandibular incisive canal-related prevalence, morphometric parameters, and implant placement implications : a multicenter study of 847 CBCT scans

2020

Background This study evaluated the epidemiological and morphological features of the mandibular incisive canal (MIC) using cone beam computed tomography (CBCT) in a significant sample of subjects in Brazil. Material and Methods This retrospective, multicenter study assessed 847 CBCT scans performed at four oral imaging centers. The sample comprised CBCT images acquired from dentate individuals who presented at least from tooth 35 to tooth 45 in the anterior mandible region. Data regarding patient sex and age, and MIC linear measurements (length and diameter in mm), anatomical distances (to the alveolar, buccal and lingual cortexes, inferior border of the mandible, and adjacent teeth apexes…

Cone beam computed tomographyMandible03 medical and health sciences0302 clinical medicinestomatognathic systemPrevalenceHumansMedicineGeneral DentistryDental alveolusRetrospective StudiesLateral incisorOrthodonticsMandibular incisive canalbusiness.industryResearchMandibleSpiral Cone-Beam Computed Tomography030206 dentistryCone-Beam Computed Tomography:CIENCIAS MÉDICAS [UNESCO]Apex (geometry)Implant placementstomatognathic diseasesOtorhinolaryngologyMulticenter studyUNESCO::CIENCIAS MÉDICASFemaleSurgerybusinessImplantologyBrazil
researchProduct

What is the frequency of anatomical variations and pathological findings in maxillary sinuses among patients subjected to maxillofacial cone beam com…

2016

Background When considering dental implant rehabilitation in atrophic posterior sectors, the maxillary sinuses must be evaluated in detail. Knowledge of the anatomical variations and of the potential lesions found in these structures conditions the outcome of sinus lift procedures and therefore of the dental implants. A systematic review is made to determine the frequency of anatomical variations and pathological findings in maxillary sinuses among patients subjected to cone beam computed tomography (CBCT). Material and Methods A PubMed (MEDLINE) literature search was made of articles published up until 20 December 2015. The systematic review was conducted based on the Preferred Reporting I…

Cone beam computed tomographyMaxillary sinusmedicine.medical_treatmentDentistrySinus liftOdontologíaReview03 medical and health sciences0302 clinical medicinePeriodonciamedicineParanasal Sinus Diseasesotorhinolaryngologic diseasesHumans030223 otorhinolaryngologySinusitisDental implantGeneral DentistrySinus (anatomy)Implantes dentalesOral Medicine and Pathologybusiness.industryAnatomic Variation030206 dentistryCone-Beam Computed TomographyMaxillary Sinusmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Systematic reviewmedicine.anatomical_structureOtorhinolaryngologyParanasal Sinus DiseasesUNESCO::CIENCIAS MÉDICASSurgerybusiness
researchProduct

Cone-beam computed tomography analysis of root and canal morphology of mandibular premolars in a Spanish population

2014

Purpose: This study aimed to investigate the clinical anatomy of lower premolar roots in a Spanish population by using cone-beam computed tomography (CBCT), correlating findings with patient gender and tooth type. Materials and Methods: Using 70 CBCT images, we evaluated 126 healthy, untreated, well-developed lower premolars. The number and morphology of roots and root canals, and the foramina number were assessed. Results for gender and tooth type were compared using the chi-squared and ANOVA tests. Results: The average length of teeth and roots was significantly higher in men (p=0.00). All 126 premolars had a single root. One canal was found in 83.3% of the premolars, with no gender or to…

Cone beam computed tomographyMorphology (linguistics)Radiological and Ultrasound Technologybusiness.industryMandibleDentistryMandibleAnatomy RegionalCone-Beam Computed TomographyClinical anatomyApex (geometry)Spanish populationmedicine.anatomical_structurestomatognathic systemPremolarmedicineotorhinolaryngologic diseasesRadiology Nuclear Medicine and imagingOriginal ArticleBicuspidApical foramenbusinessGeneral DentistryImaging Science in Dentistry
researchProduct

Alignment of cone beam computed tomography data using intra-oral fiducial markers.

2009

This article illustrates a new method to align and merge two partially overlapping volumes each of them generated by cone beam computed tomography (CBCT). The aggregate volume covers a larger area of investigation and is determined by localizing one fixed LEGO brick in both of the primal volumes. Based on the LEGO brick an approximate registration of the volumes is determined. Afterwards we improve the transformation by minimizing the difference in overlapping space. In this paper we present a method which automates these two steps and provides an aligned volume.

Cone beam computed tomographyMouthRadiological and Ultrasound Technologybusiness.industryComputer sciencePhantoms ImagingHealth InformaticsRadiography Dental DigitalCone-Beam Computed TomographyComputer Graphics and Computer-Aided DesignComputer Science::Computers and SocietyOpticsJawIntra oralHumansRadiology Nuclear Medicine and imagingComputer visionComputer Vision and Pattern RecognitionArtificial intelligencebusinessFiducial markerMerge (version control)Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
researchProduct

Is periapical surgery follow-up with only two-dimensional radiographs reliable? A retrospective cohort type sensitivity study

2021

Background Two-dimensional (2D) radiographic techniques are commonly used for assessing lesion prognosis after endodontic surgery. The present retrospective cohort study analyzes the sensitivity and ability of different radiographic techniques in obtaining area and volume measurements of periapical lesions. Material and Methods Preoperative and follow-up (6-48 months) periapical and panoramic radiographs (index test) and cone-beam computed tomography (CBCT) images (reference standard) were selected from an endodontic microsurgery database. Sensitivity was analyzed independently by two examiners. The areas of the 2D radiographic images and CBCT volumes were studied using Itk-Snap software an…

Cone beam computed tomographyRadiographyComputed tomographybubr1oral leukoplakiaRadiography Panoramicepithelial dysplasiaHumansMedicineGeneral DentistryReference standardsspindlyUNESCO:CIENCIAS MÉDICASRetrospective Studiesmedicine.diagnostic_testbusiness.industryResearchPeriapical radiographyRetrospective cohort studyCone-Beam Computed Tomographyrespiratory systembub3mad2oral squamous cell carcinomaVolume measurementsOtorhinolaryngologySurgeryOral SurgeryNuclear medicinebusinessToothPeriapical surgeryFollow-Up StudiesMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Radiation dose in non-dental cone beam CT applications: a systematic review.

2018

Background: Radiation-induced health risks are broadly questioned in the literature. As cone beam computed tomography (CBCT) is increasingly used in non-dental examinations, its effective dose needs to be known. This study aimed to review the published evidence on effective dose of non-dental CBCT for diagnostic use by focusing on dosimetry system used to estimate dose. Materials and methods: A systematic review of the literature was performed on 12 November 2017. All the literature up to this date was included. The PubMed and web of science databases were searched. Studies were screened for inclusion based on defined inclusion and exclusion criteria according to the preferred reporting ite…

Cone beam computed tomographyRadiology Nuclear Medicine and ImagingComputed tomography dose indexCone beam computed tomographyRadiation DosageEffective dose (radiation)Imaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineMedicineDosimetryHumansSkeletal imagingEffective dosebusiness.industry030206 dentistryGeneral MedicineCone-Beam Computed TomographyParanasal sinusesmedicine.anatomical_structureDose area productInclusion and exclusion criteriabusinessNuclear medicineHeadNeckHead and neck imagingHumanLa Radiologia medica
researchProduct

Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study

2017

AbstractThe accuracy of Cone-Beam Computed Tomography (CBCT) on linear and volumetric measurements on condyles has only been assessed on dry skulls. The aim of this study was to evaluate the reliability and accuracy of linear and volumetric measurements of mandibular condyles in the presence of soft tissues using CBCT. Six embalmed cadaver heads were used. CBCT scans were taken, followed by the extraction of the condyles. The water displacement technique was used to calculate the volumes of the condyles and three linear measurements were made using a digital caliper, these measurements serving as the gold standard. Surface models of the condyles were obtained using a 3D scanner, and superim…

Cone beam computed tomographyScannerMaterials sciencelcsh:MedicineDentistryurologic and male genital diseasesArticleCondyle030218 nuclear medicine & medical imaging03 medical and health sciencesImaging Three-Dimensional0302 clinical medicinestomatognathic systemCadaverCadaverHumanslcsh:ScienceReliability (statistics)Human cadaverMultidisciplinaryAnthropometrybusiness.industrylcsh:RMandibular Condyle030206 dentistryCone-Beam Computed Tomographyrespiratory systemequipment and suppliesClinical diagnosisCaliperslcsh:QbusinessBiomedical engineeringScientific Reports
researchProduct

Interobserver and intraobserver variability in the radiological assessment of sialolithiasis using cone beam computed tomography

2021

Background Data regarding the inter- and intraobserver variability in the radiological assessment of sialolithiasis using cone beam computed tomography are missing in the current literature. This study assessed the inter- and intraobserver variability in the radiological assessment of sialolithiasis using cone beam computed tomography (CBCT). Material and Methods In 107 patients, 130 salivary glands (65 parotid and 65 submandibular) with clinical signs of obstruction were assessed by four independent observers; 2 residents OMFS and 2 experienced OMFS. The observers analyzed the CBCT images and determined the absence or presence of one or more salivary stones in the affected gland. This proc…

Cone beam computed tomographycone-beam computed tomographyACCURACYSALIVARY STONESSalivary gland calculiSigns and symptomsnon-hodgkin lymphomahivSONOGRAPHYsurvivalstomatognathic systemMedicineHumansParotid GlandGeneral DentistryUNESCO:CIENCIAS MÉDICASOral Medicine and Pathologybusiness.industryResearchBackground dataSignificant differenceCone-beam computed tomographyCBCToral cancerSubmandibular glandobserver variationParotid glandmedicine.anatomical_structureObserver variationOtorhinolaryngologyRadiological weaponSurgeryprognosisbusinessNuclear medicineSIALENDOSCOPYKappa
researchProduct

Symmetry of root and root canal morphology of mandibular incisors: A cone-beam computed tomography study

2019

Background Aim of this study was to analyze the root canal configuration in mandibular central and lateral incisors in vivo using cone-beam computed tomography (CBCT) imaging. Material and methods A total of 487 mandibular central incisors and 491 mandibular lateral incisors from 250 patients were examined using CBCT imaging, previously taken for diagnosis and treatment. The number of roots, root canal system configuration, presence of apical confluences, distance between confluences and radiographic root end, symmetry between left and right elements were recorded and statistically analyzed. Results All the examined teeth presented only one root. No significant differences were found betwee…

Cone beam computed tomographycone-beam computed tomographyRoot canalRadiography050801 communication & media studiesComputed tomographyOperative Dentistry and Endodontics03 medical and health sciencescone-beam computed tomography; confluences; mandibular incisors; root canal anatomy0302 clinical medicine0508 media and communicationsstomatognathic systemmandibular incisorsmedicineotorhinolaryngologic diseasesMaxillary central incisorGeneral DentistryOrthodonticsmedicine.diagnostic_testbusiness.industryResearch05 social sciences030206 dentistrySystem configurationRoot canal morphology:CIENCIAS MÉDICAS [UNESCO]Cbct imagingstomatognathic diseasesmedicine.anatomical_structureroot canal anatomyUNESCO::CIENCIAS MÉDICASconfluencesbusinessJournal of clinical and experimental dentistry
researchProduct