Search results for "Cone-beam computed tomography"
showing 10 items of 90 documents
Accelerating orthodontic tooth movement: a new, minimally-invasive corticotomy technique using a 3D-printed surgical template
2015
Background A reduction in orthodontic treatment time can be attained using corticotomies. The aggressive nature of corticotomy due to the elevation of muco-periosteal flaps and to the duration of the surgery raised reluctance for its employ among patients and dental community. This study aims to provide detailed information on the design and manufacture of a 3D-printed CAD-CAM (computer-aided design and computer-aided manufacturing) surgical guide which can aid the clinician in achieving a minimally-invasive, flapless corticotomy. Material and Methods An impression of dental arches was created; the models were digitally-acquired using a 3D scanner and saved as STereoLithography ( STL ) file…
Editorial 1/2016
2015
It is with great pleasure to wish all our readers, authors and reviewers a happy and healthy new year 2016! Dentomaxillofacial Radiology is fortunate to look back on some rather successful years. Our speciality, that is, oral and maxillofacial (radiological) imaging gained increasing importance over the past decade, which is predominantly a result of the success of CBCT. Lately, we have seen an increasing number of articles (e.g. Petersen Johan Aps Gang Li
Diagnosis and treatment of dens invaginatus with open apex in a young adult patient by using cone-beam computed tomography and operative microscope.
2021
BACKGROUND: Dens invaginatus is a developmental anomaly that can affect both deciduous and permanent dentition. The anomaly is caused by the invagination of the enamel organ into the dental papilla prior to the calcification of the dental tissues. The treatment option changes according to the classification, from the simple filling of the invaginated enamel area to root canal treatment with or without retrograde surgery, intentional re-implantation, or the extraction of the affected tooth. CASE REPORT: In this study we report a case of a maxillary lateral incisor invaginatus in a young adult patient. The periapical endoral X-ray showed the presence of a periapical radiolucency in tooth 22, …
Effects of minute misregistrations of prefabricated markers for image-guided dental implant surgery: an analytical evaluation
2012
Objectives The goal of the present study was to develop a theoretical analysis of errors in implant position, which can occur owing to minute registration errors of a reference marker in a cone beam computed tomography volume when inserting an implant with a surgical stent. Material and methods A virtual dental-arch model was created using anatomic data derived from the literature. Basic trigonometry was used to compute effects of defined minute registration errors of only voxel size. The errors occurring at the implant's neck and apex both in horizontal as in vertical direction were computed for mean ±95%-confidence intervals of jaw width and length and typical implant lengths (8, 10 and 1…
Relation between the distance from the cementoenamel junction to the bone crest and the thickness of the facial bone in anterior maxillary teeth: A c…
2018
Background The purpose of this cross-sectional study was to evaluate radiologically, the relation between the distance from the cementoenamel junction (CEJ) to the facial bone crest (FBC), and the facial alveolar bone (FAB) width at maxillary anterior teeth. A further aim was to assess if the CEJ-FBC distance had an impact in the prevalence to find a FAB thickness greater than one mm. Material and Methods CBCT images were retrospectively obtained from the database of the Oral Surgery Unit of the University of Valencia. The teeth were divided in 3 groups according to the CEJ-FBC distance: Shorter (≤3mm), Middle (>3 ≤4.5 mm) and Larger (>4.5 mm). FAB thickness was measured by two different ex…
Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.
2019
Purpose Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to develop a marker-free iterative motion correction algorithm that works on the projection images and is suitable for local tomography. Methods We present an iterative motion correction algorithm that allows the patient's motion to be detected and taken into account during reconstruction. The core of our method is a fast GPU-accelerated three-dimensional reconstruction algorith…
Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.
2011
Objectives The aim of the present investigation was the analysis of the factors presumptively affecting the accuracy outcome of cone-beam computed tomography (CBCT)-derived laboratory-based surgical guides for implant placement in partially edentulous patients. Materials and methods In 52 partially edentulous patients a total of 132 implants were placed following CBCT diagnostics with the aid of laboratory-fabricated, tooth-borne templates. Based on the image fusion technique measurements were done to calculate linear and angular deviations between virtually planned and placed implants. The implant sites were stratified according to four factors that presumably may influence the transfer ac…
Facial alveolar bone thickness and modifying factors of anterior maxillary teeth: a systematic review and meta-analysis of cone-beam computed tomogra…
2021
Abstract Background Understanding the anatomy of the facial alveolar bone (FAB), provides a prognostic tool for estimating the degree of dimensional ridge alterations after tooth extraction. This systematic review and meta-analysis aims to determine the FAB thickness and modifying factors of anterior maxillary teeth measured by CBCT scans. A secondary objective was to assess the facial distance from the cementoenamel junction (CEJ) to the bone crest. Methods An electronic search was made of Medline, Embase, Web of Science, Cochrane Library and Google Scholar up to December 2019. Studies that analyze and quantitatively compare FAB thickness at maxillary teeth by CBCT scans were included. The…
Assesment of accessory branches of canalis sinuosus on CBCT images
2019
Background The aim of this study is to describe the presence, to reveal the frequency and characteristics of accessory canals (ACs) of the canalis sinuosus (CS) by cone beam computed tomography (CBCT). Material and Methods A total of 326 CBCT examinations were scanned retrospectively. The anatomical views were evaluated on sagittal, axial, coronal and cross sectional imaging. The following parameters were recorded: age, sex, presence or absence of ACs, location in relation to the adjacent teeth and distance to the nasal cavity floor (NCF), alveolar ridge crest (ARC) and buccal cortical bone (BCB), and incisive canal. All the collected data were statistically analyzed. Results 113 patients (…
Changes in dimension of neurovascular canals in the mandible and maxilla: A radiographic finding in patients diagnosed with MRONJ.
2017
Background The aim of this retrospective study was to compare the morphological features of neurovascular canals and foramina of patients with medication-related osteonecrosis of the jaws (MRONJ) and healthy individuals by using cone beam computed tomography (CBCT). Material and Methods The CBCT images of 58 patients under bisphosphonate therapy diagnosed with MRONJ and age gender- matched controls were retrospectively evaluated. The diameter of mandibular and nasopalatine canal and mandibular, mental and lingual foramina were measured on several sections of CBCT. The value of mental index (MI) and panoramic mandibular index (PMI) were also assessed. Results The mean value of diametric meas…