Search results for "Contrast Sensitivity"
showing 10 items of 115 documents
Surface Lightness Influences Perceived Room Height
2010
Surprisingly little scientific research has been conducted on the effects of colour and lightness on the perception of spaciousness. Practitioners and architects typically suggest that a room's ceiling appears higher when it is painted lighter than the walls, while darker ceilings appear lower. Employing a virtual reality setting, we studied the effects of the lightness of different room surfaces on perceived height in two psychophysical experiments. Observers judged the height of rooms varying in physical height as well as in the lightness of ceiling, floor, and walls. Experiment 1 showed the expected increase of perceived height with increases in ceiling lightness. Unexpectedly, the perce…
Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering
2013
Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …
Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery
2013
To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…
Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator
2013
PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …
Mesopic contrast sensitivity function after excimer laser photorefractive keratectomy.
2002
ABSTRACT PURPOSE: To evaluate contrast sensitivity under mesopic conditions in patients who had undergone uncomplicated excimer laser photorefractive keratectomy (PRK) for myopia. METHODS: Monocular contrast sensitivity function was measured with the Stereo Optical ?A.C.T. chart in 26 patients who had received PRK using the Nidek EC-5000 excimer laser system. Mean preoperative refractive error was -6.23 ? 1.69 D (range, -4.00 to -8.25 D); postoperatively, mean refractive error was -0.36 ? 0.58 D (range, -0.75 to +0.50 D). Contrast sensitivity function was measured 6 months after surgery using four different chart luminances: 85, 5.0, 2.5, and 0.1 cd/m2, the first being a photopic level and …
Mesopic Contrast Sensitivity Function After Laser in situ Keratomileusis
2003
ABSTRACT PURPOSE: To evaluate contrast sensitivity under mesopic conditions in patients who have undergone uncomplicated bilateral laser in situ keratomileusis (LASIK) for myopia. METHODS: Best-corrected monocular contrast sensitivity was measured with the Stereo Optical F.A.C.T. chart at 1.5, 3, 6, 12, and 18 c/deg in 20 patients (20 left eyes) before and after bilateral LASIK (with the Nidek EC-5000 excimer laser and the Automated Corneal Shaper). Mean preoperative refractive error was -6.40 ± 1.28 D (range -4.00 to -8.00 D) and postoperative mean refractive error was -0.41 ± 0.45 D (range -0.75 to +0.50 D). Contrast sensitivity function was measured before and 6 months after surgery usin…
Comparison of short-term light disturbance, optical and visual performance outcomes between a myopia control contact lens and a single-vision contact…
2020
Purpose To compare the optical and visual performance of a dual-focus (DF) contact lens used for myopia control with a single-vision (SV) contact lens of the same material. Methods A randomised, double-masked crossover study. Twenty-eight healthy, myopic volunteers between 18 and 32 years of age (23.49 +/- 4.07 years) participated in this study. The sensory dominant eye for distance vision was determined. Refraction, best-corrected visual acuity (VA) and aberrations for 3 mm and 5 mm pupil diameters were quantified without a contact lens in situ. Subjects were fitted with two contact lens designs: DF and SV, both made of omafilcon A material. The Quality of Vision (QoV) questionnaire, over-…
Visual performance of two simultaneous vision multifocal contact lenses
2012
Purpose To evaluate and compare the visual performance of two simultaneous vision multifocal contact lenses (CLs). Methods In this cross-over study design 20 presbyopic subjects were fitted with two different simultaneous vision multifocal CLs (the PureVision Multifocal Low Add and Acuvue Oasys for Presbyopia) in random order. After 1 month, binocular distance visual acuity (BDVA) under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions, binocular near visual acuity (BNVA), binocular distance contrast sensitivity function (CSF) under photopic and mesopic conditions, binocular near CSF and defocus curve were measured. Subjects were then refitted with the alternative correction and the proc…
Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.
2007
To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…
Visual function after implantation of a diffractive aspheric trifocal intraocular lens
2016
Purpose To evaluate distance, intermediate, and near vision after bilateral implantation of a diffractive aspheric trifocal intraocular lens (IOL). Methods This study enrolled 204 eyes of 102 patients who had bilateral implantation of the AT LISA tri 839MP IOL. Monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (4 meters), monocular and binocular uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) (30, 40 centimeters), binocular uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA) (50, 60, 70 centimeters), the defocus curve, and binocular photopic…