Search results for "Contrast media"
showing 10 items of 323 documents
A multicenter, site-independent, blinded study to compare the diagnostic accuracy of contrast-enhanced magnetic resonance angiography using 1.0M gado…
2007
Abstract Purpose Prospective evaluation of diagnostic accuracy of single field-of-view contrast-enhanced MR Angiography (ceMRA) with 1.0 M gadobutrol compared to intraarterial DSA in body arteries. Materials and methods In an European multicenter study 179 patients underwent ceMRA and DSA. For each indication five prospectively defined vessel segments were evaluated by local investigators onsite and by three site-independent blinded readers (BR) independently. Results The agreement between ceMRA and DSA diagnosis was statistically significant in the onsite (96.6%) and blinded reader (86.6–90.2%) evaluation. Sensitivity, specificity, accuracy, positive (PPV) and negative predictive values (N…
Resovist enhanced MR imaging of the liver: Does quantitative assessment help in focal lesion classification and characterization?
2009
Purpose: To improve characterization of focal liver lesions by a prospective quantitative analysis of percentage signal intensity change, in dynamic and late phases after slow (0.5 mL/s) Resovist administration. Materials and Methods: Seventy-three patients were submitted on clinical indication to MR examination with Resovist. Signal intensity of 92 detected focal lesions (5–80 mm) were measured with regions of interest and normalized to paravertebral muscle in arterial, portal, equilibrium and T1/T2 late phases, by two observers in conference. Five values of percentage variations per patient were obtained and statistically evaluated. Results: The enhancement obtained on dynamic study is mo…
Diagnostic performance of gadobenate dimeglumine enhanced MR angiography of the iliofemoral and calf arteries: a large-scale multicenter trial
2007
OBJECTIVE. The purpose of this study was to compare gadobenate dimeglumine–enhanced MR angiography and unenhanced time-of-flight MR angiography for the detection of significant peripheral arterial occlusive disease using digital subtraction angiography as our reference standard. SUBJECTS AND METHODS. Two hundred seventy-two patients underwent MR angiography and digital subtraction angiography of the iliofemoral arteries. MR angiography was performed before (2D time-of-flight acquisitions) and after (spoiled gradient-echo acquisitions) the administration of 0.1 mmol/kg of gadobenate dimeglumine at 1–2 mL/s. Contrast-enhanced MR angiography and digital subtraction angiography of the calf arte…
Assessment of the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level in patients with emphysema.
2006
Abstract Purpose To assess the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level using CT and MRI in patients with emphysema. Material and methods Forty-five patients with severe emphysema (GOLD III and IV) underwent inspiratory 3D-HRCT and contrast-enhanced MR-perfusion (1.5T; 3.5 mm × 1.9 mm × 4 mm). 3D-HRCT data was analyzed using a software for detection and visualization of emphysema. Emphysema was categorized in four clusters with different volumes and presented as overlay on the CT. CT and lung perfusion were visually analyzed for three lobes on each side using a four-point-score to grade the abnormalities on CT (1: predominantly smal…
Splenic hemangiomas: contrast-enhanced sonographic findings
2012
Objectives The purpose of this study was to illustrate the baseline appearance and enhancement patterns of splenic hemangiomas on contrast-enhanced sonography. Methods Two experienced radiologists retrospectively reviewed by consensus baseline and contrast-enhanced sonographic examinations of 27 patients (14 women and 13 men; mean age, 58.7 years) with 27 splenic hemangiomas (mean size, 2 cm) confirmed by splenectomy, biopsy, computed tomography, and magnetic resonance imaging and follow-up. Results On baseline sonography, 77.8% of the lesions showed a homogeneous echo texture that was mainly hyperechoic. Color Doppler imaging did not show any signal in 81.5% of the cases. After contrast ag…
Barium study associated with water siphon test in gastroesophageal reflux disease and its complications.
2007
PURPOSE: The aim of this study was to evaluate the role of digital cineradiography associated with the water siphon test (WST) in the diagnosis of gastroesophageal reflux and to compare the results with oesophageal motility study, pH monitoring and endoscopy associated with biopsy and histology. MATERIALS AND METHODS: One hundred and sixty consecutive patients underwent digital cineradiography with WST, motility study, pH monitoring and endoscopy with biopsy. The presence of gastroesophageal reflux, oesophagitis, Barrett''s oesophagus and intestinal metaplasia was evaluated. RESULTS: WST vs. pH monitoring showed sensitivity of 71%, specificity of 31%, positive predictive value (PPV) of 53% …
Left ventricular volume determination using Albunex.
1996
The aim of this study was to assess the ability of intravenous injection of Albunex to improve left ventricular volume determination in patients with various cardiac diseases. It is conceivable that the intravenous injection of microbubbles could improve echocardiographic left ventricular border delineation leading to improved interobserver variability. Echocardiograms were obtained during simultaneous intravenous injection of 0.08 and 0.12 ml/kg Albunex (four-chamber view). Within 6 hours after the recording of the contrast echocardiograms routine left heart angiography was performed. Volumes were measured using the slice method in native and contrast echocardiograms as well as in the angi…
Freehand three-dimensional assessment of left ventricular volumes and ejection fraction with ultrasound contrast agent LK565
2005
Accurate assessment of left ventricular function by determining left ventricular volumes and ejection fraction is important in evaluating the prognoses of patients with heart failure. Two-dimensional (2D) echocardiography suffers from low correlation with reference methods like ventriculography. Three-dimensionally (3D) assessed data have been proved to have better conformity. Endocardial border delineation remains a problem, however, especially in patients with suboptimal recordings. Few data exist on 3D-echocardiographic volumetry with ultrasound contrast agents (UCAs). We evaluated the second-generation UCA LK565 for its boundary-tracing capacities in freehand 3D echocardiography in a ph…
Value of contrast-enhanced MR angiography and helical CT angiography in chronic thromboembolic pulmonary hypertension.
2003
The aim of this study was to evaluate the diagnostic value of contrast-enhanced MR angiography (ce MRA) and helical CT angiography (CTA) of the pulmonary arteries in the preoperative workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH). The ce MRA and CTA studies of 32 patients were included in this retrospective evaluation. Image quality was scored by two independent blinded observers. Data sets were assessed for number of patent segmental, subsegmental arteries, and number of vascular segments with thrombotic wall thickening, intraluminal webs, and abnormal proximal to distal tapering. Image quality for MRA/CTA was scored excellent in 16 of 16, good in 11 of 14, m…
MR angiography of the pedal arteries with gadobenate dimeglumine, a contrast agent with increased relaxivity, and comparison with selective intraarte…
2007
Purpose To compare gadobenate dimeglumine (Gd-BOPTA)–enhanced MR angiography (i.e., contrast-enhanced MRA [CE-MRA]) of the pedal vasculature with selective digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). Materials and Methods A total of 22 patients with PAOD were prospectively examined at 1.5T. For contrast enhancement, 0.1 mmol/kg body weight of Gd-BOPTA were applied. MRA consisted of dynamic imaging with acquisition of six consecutive data sets. Acquisition time for each data set was 24 seconds, voxel size was 1.0 × 1.0 × 1.3 mm3. A total of 20 out of 22 patient underwent selective DSA, two patients fine-needle DSA. DSA and MRA were per…