Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.
2008
We reviewed recently published studies that analyzed the visual and optical quality in eyes with different spherical and aspheric intraocular lenses (IOLs). Recent studies focused on visual quality metrics, such as visual acuity and contrast sensitivity, under photopic and mesopic lighting conditions and optical metrics, such as wavefront aberrations, especially spherical aberration. The results in this review were used in an attempt to understand whether there is a visual and/or optical benefit of implanting aspheric IOLs over implanting spherical IOLs.
Accommodation-related changes in monochromatic aberrations of the human eye as a function of age.
2008
PURPOSE. To investigate the relationship between accommodation and the optical aberrations of the whole human eye, as a function of age. METHODS. Sixty healthy subjects with spherical ametropia in the range 3 D, astigmatism less than 1 D, corrected visual acuity of 20/18 or better, and normal findings in an ophthalmic examination were enrolled. Subjects were divided into four groups, with age ranges of 19 to 29, 30 to 39, 40 to 49, and 50 to 60 years. Monochromatic optical aberrations and pupil size were measured with a Hartmann-Shack wavefront sensor under monocular viewing conditions, without pharmacological dilation or cycloplegia. Stimulus vergences were in the range of 0 to 5 D, with a…
Corneo-scleral contact lens in a piggyback system for keratoconus: A case report.
2017
Purpose: We describe a case of fitting a corneo-scleral contact lens with a multi-aspheric geometry design (MAGD CScL) on top of a daily silicone hydrogel lens (piggyback system) for keratoconus management. Methods: A 48-year-old man using soft toric contact lenses required an improvement in the unsatisfactory quality of his vision. He presented with bilateral asymmetric keratoconus with high myopia in the right eye (RE) and severe myopia in the left eye (LE). In addition, he had low vision in his LE because of a maculopathy. He was fitted with MAGD CScL to correct his irregular astigmatism. A diagnostic trial set was used in the fitting process and the patient was assessed according to a s…
Diurnal variations in visual performance for disposable contact lenses.
2013
The purpose of this study is to compare the visual performance provided by different daily disposable contact lenses and to analyze its variation over time.Visual performance was evaluated in terms of visual acuity (VA) and contrast sensitivity (CS) in 15 myopic subjects (-0.50 to -4.00 diopters) who had been previously fitted with each one of the following seven types of soft contact lenses: DAILIES TOTAL1 (Alcon, Forth Worth, TX), DAILIES AquaComfort Plus (Alcon), 1-DAY ACUVUE TruEye (JohnsonJohnson Vision Care, Jacksonville, FL), 1-DAY ACUVUE MOIST (JohnsonJohnson Vision Care), SofLens daily disposable (BauschLomb, Rochester, NY), Proclear 1 Day (CooperVision, Fairport, NY), and Clariti …
Pelēki tonētu lēcu ietekme uz redzes funkcijām
2017
Darbs ir uzrakstīts andļu valodā uz 27 lapaspusēm, tajā ir 12 attēli, 2 tabulas un 36 litteratūras avoti. Darba mērķis bija novērtēt, kā samazināta apgaismojuma apstākļi ietekmē redzes funkcijas gados jaunākiem un vecākiem dalībniekiem. Gados jauniem (21 – 35 gadi) un vecākiem (60 – 75 gadi) dalībniekiem tika mērīts augsta un zema kontrasta redzes asums. Mērījumi tika veikti ar un bez pelēki tonētām lēcām, kuru gaismas caurlaidība bija 50 %. Rezultāti parādīja, ka lielāks redzes asuma samazinājums, samazinoties optotipu kontrastam, bija novērojams gados vecākiem dalībniekiem. Skatoties caur tonētajām lēcām, standarta kontrasta redzes asums vairāk samazinājās gados vecākiem nekā jaunākiem da…
Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens
2009
Purpose To determine whether the difference in optic quality between 2 types of phakic intraocular lenses (pIOLs) affects visual quality. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Before implantation of a pIOL for myopia, all eyes had an examination including corrected (CDVA) and uncorrected (UDVA) distance visual acuity testing, corneal endothelial cell count (ECC), and intraocular pressure (IOP) measurement. The postoperative outcomes, determined at least 1 year after surgery, were CDVA; UDVA; contrast sensitivity function under photopic, mesopic, and mesopic with glare conditions; ECC; IOP; keratometry (Scheimpflug photography); and total ocular aberratio…
Image quality with multifocal intraocular lenses and the effect of pupil size
2007
Purpose To analyze the image quality with a refractive and 2 hybrid refractive–diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods This study evaluated 4 IOLs: the hybrid refractive–diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Sci…
Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens
2013
Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof ReSTOR (SN6AD3 model) intraocular lens (IOL) Methods: Sixty eyes of 30 consecutive patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patients sample was divided into myopic [n=15, mean spherical equivalent (SE) -6.87± 2.03 diopters (D)] and hyperopic (n=15, mean SE +4.52±1.14 D) groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respec…
Influence of the contrast sensitivity function on the reaction time
1993
The reaction time (RT) vs spatial frequency (SF) curve is determined, using gratings from 1 to 40 c/deg, at seven different contrast levels between 0.95 and 0.02. The form of the RT/SF function: (a) replicated the inverse of the contrast sensitivity function (CSF) at near threshold contrast levels; (b) behaved differently at higher contrasts, exhibiting two branches at contrast close to 1. The interpretation is that there are two factors determining this function: (1) the transition from the operation of fast transient channels at low SF to the operation of slow sustained channels at high SF, the transition taking place within a narrow SF band close to 6 or 8 c/deg (depending on the subject…
Femtosecond laser versus mechanical keratome LASIK for myopia.
2005
To assess efficacy, safety, predictability, stability, and changes in corneal higher-order aberrations (CHOAs) and contrast sensitivity (CS) after a femtosecond laser for LASIK and standard LASIK for myopia.Prospective, randomized, comparative clinical study.Two hundred eyes of 100 consecutive patients who underwent LASIK treatment using the VISX S2 laser system. A femtosecond laser for flap creation was used in 100 eyes (50 patients; spherical equivalent [SE], -2.85+/-1.79 diopters [D]), and a mechanical microkeratome was used in 100 eyes (50 patients; SE, -2.90+/-1.63 D).Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, CS by means of t…