Cascaded PD-PI controller for active power frequency control of two-area multi-units power system

2016

In interconnected multi-area power system; the real power generation within each area has to be managed through active power frequency control considering scheduled power exchange. In this work, two different controllers, namely cascaded PD-PI and conventional PID controller are considered for analyzing the dynamic response of the two area interconnected power system. Area-1 consists of two reheat type thermal generating power plant units and area-2 comprises of two non-reheat type thermal power plant units. The controller gains of PD-PI and PID controllers are efficiently tuned by ‘Teaching Learning based Optimization Technique’. In area-1, 1% step load disturbance is applied for analyzing…

EngineeringPower stationbusiness.industry020209 energyAutomatic frequency controlPID controllerControl engineering02 engineering and technologyAC powerElectric power systemElectricity generationControl theory0202 electrical engineering electronic engineering information engineeringbusinessPower control2016 IEEE International Conference on Power and Renewable Energy (ICPRE)
researchProduct

A Low-cost, Real-time Monitoring System for PV Plants based on ATmega 328P-PU Microcontroller

2015

This paper presents a real-time monitoring system for PV power plants based on a microcontroller Atmega328P-PU. The proposed system, whose performances can be relatively close to those achieved with commercial monitoring systems, is simple, low-cost and open source technology-based. In addition, a user interface, capable to communicate through a wireless network by using a standard communication protocol IEEE 802.15.1, is here presented. From the experimental tests described and discussed in this paper it is demonstrated that the proposed monitoring system provides, with adequate accuracy, all the information about the operating status of the PV plant, even during fault conditions.

EngineeringSIMPLE (military communications protocol)business.industryWireless networkMonitoring systemSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciFault (power engineering)MicrocontrollerSettore ING-IND/31 - ElettrotecnicaPV Plant real time monitoringEmbedded systemUser interfacebusinessCommunications protocolSettore ING-INF/07 - Misure Elettriche E ElettronichePv power
researchProduct

Obtaining dynamic Norton parameters of a solar panel from manufacturer data

2016

Photovoltaic arrays have been shown to possess significant influence on the dynamic performance of coupled source-converter-load system while its dynamic resistance is the most important parameter, contributing to the overall system dynamics. In this paper, a method of deriving the parameters of linearized photovoltaic equivalent circuit from manufacturer data is proposed. The approach allows predicting the range of dynamic Norton parameters for the expected irradiation and temperature operation conditions thus defining clear bounds required for robust design of the system controller.

EngineeringSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industryPhotovoltaic systemPhotovoltaic arraysControl engineeringstabilitySystem dynamicsDynamic resistanceRobust designRange (statistics)Solar energy generatorEquivalent circuitbusinessdynamic resistanceSystem controller
researchProduct

Comparing different control strategies for indoor thermal comfort aimed at the evaluation of the energy cost of quality of building

2010

Abstract The rapid improvement in the standard of living requires more detailed and sophisticated methods of evaluating comfort conditions. But, maintaining thermal comfort conditions in confined environments may require complex regulation procedures and the proper management of heating, ventilating and air conditioning (HVAC) systems. In turn, the requirements for indoor thermal comfort do not necessarily coincide with those of energy saving purposes, which in the last years are becoming a crucial issue owing to the enactment of the European Energy Performance of Buildings Directive (EPBD). The aim of this work is to compare different indoor control thermal comfort strategies in view of th…

EngineeringSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industrymedia_common.quotation_subjectWork (physics)Energy Engineering and Power TechnologyPID controllerThermal comfortControl engineeringIndustrial and Manufacturing EngineeringReliability engineeringControl theoryAir conditioningHVACQuality (business)indoor thermal comfort quality building energy performancebusinessEnergy (signal processing)media_commonApplied Thermal Engineering
researchProduct

Type-2 fuzzy control of a fed-batch fermentation reactor

2010

Abstract The aim of the paper is to present the application of type-2 fuzzy logic controllers (T2FLCs) to the control of a fed-batch fermentation reactor in which the penicillin production is carried out. The performance of the control system using T2FLCs is compared by simulation with that of a control system using type-1 fuzzy logic controllers (T1FLCs). The non linear model used for the simulation study is an unstructured model characterized by the presence of non linearities, parameter uncertainty and measurement noise. Simulation results confirm the robustness of the T2FLC which shows a better performance than its type-1 counterpart particularly when uncertainties are present in the co…

EngineeringSettore ING-IND/26 - Teoria Dello Sviluppo Dei Processi ChimiciBatch fermentationbusiness.industryNon linear modelControl engineeringFuzzy control systemType (model theory)Fuzzy logicNoiseControl theoryRobustness (computer science)Control systemtype-2 fuzzy logic controller uncertainties non linear system fed batch fermentation reactorbusiness
researchProduct

Control of the Biodegradation of Mixed Wastes in a Continuous Bioreactor by a Type-2 Fuzzy Logic Controller

2009

Abstract Type-2 fuzzy logic control is proposed for nonlinear processes characterized by bifurcations. A control simulation study was conducted for a bioreactor with cell recycle containing phenol and glucose as carbon and energy sources in which a pure culture of Pseudomonas putida is carried out. The model developed by Ajbar [Ajbar, A. (2001). Stability analysis of the biodegradation of mixed wastes in a continuous bioreactor with cell recycle. Water Research, 35 (5), 1201–1208] was used for the simulations. The particular dynamics of the bioreactor, characterized by two saddle-node bifurcations, makes its control difficult, since it may become unstable also for small variations of some p…

EngineeringSettore ING-IND/26 - Teoria Dello Sviluppo Dei Processi Chimicibusiness.industryGeneral Chemical EngineeringOpen-loop controllerPID controllerControl engineeringFuzzy control systemFuzzy logicComputer Science ApplicationsNonlinear systemBifurcation Bioreactor control Stability Type-2 fuzzy logic controllerControl theoryRobustness (computer science)Energy sourcebusiness
researchProduct

Nonlinear control of an activated sludge aeration process: use of fuzzy techniques for tuning PID controllers

1999

In this paper, several tuning algorithms, specifically ITAE, IMC and Cohen and Coon, were applied in order to tune an activated sludge aeration PID controller. Performance results of these controllers were compared by simulation with those obtained by using a nonlinear fuzzy PID controller. In order to design this controller, a trial and error procedure was used to determine, as a function of error at current time and at a previous time, sets of parameters (including controller gain, integral time and derivative time) which achieve satisfactory response of a PID controller actuating over the aeration process. Once these sets of data were obtained, neural networks were used to obtain fuzzy m…

EngineeringSewageArtificial neural networkbusiness.industryApplied MathematicsOpen-loop controllerPID controllerControl engineeringNonlinear controlFuzzy logicComputer Science ApplicationsKineticsNonlinear systemOxygen ConsumptionFuzzy LogicNonlinear DynamicsControl and Systems EngineeringControl theoryProcess controlComputer SimulationBiomassElectrical and Electronic EngineeringbusinessInstrumentationAlgorithmsISA Transactions
researchProduct

Design, sizing and set up of a specific low cost electronic load for PV modules characterization

2013

In this paper, the design, sizing and set-up of a specific low cost electronic load, based on a DC-DC step-down converter, suitable for the PV module I - V characteristic curves determination, is described. In particular, for its set up, a low cost and user friendly micro-controller has been employed in order to generate the PWM signal. The measures carried out connecting the electronic load prototype to a commercial PV module are here presented and discussed. The conceived electronic load has allowed the determination of 80% of the PV module characteristic curves in 2 s. This low measurement time, lower than the time intervals in which weather conditions may change, allows to assume as con…

EngineeringSignal generatorbusiness.industryRippleSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciSignalSizingElectronic Load PV modules I-V characteristic curvesSet (abstract data type)MicrocontrollerElectronic engineeringMATLABbusinesscomputerPulse-width modulationcomputer.programming_language2013 Eighth International Conference and Exhibition on Ecological Vehicles and Renewable Energies (EVER)
researchProduct

An embedded diagnostic system for wheelchairs brushless drives monitoring

2006

The implementation of a microcontroller based monitoring system for the diagnosis of a brushless synchronous motor drives is presented. It finds its primarily interest on motorized wheelchair for disabled people. The embedded system mainly controls all the principal parameters of the electrical drives together with the power supply system. Pre-failure and failure conditions are routinely logged and, depending on the malfunction severity, alarm messages are created and sent to a remote base station by using the GSM wireless network.

EngineeringTechnologyremote diagnosticsbusiness.industryWireless networkRemote base stationCondition monitoringVehiclesMicrocontrollerWheelchairGSMControl systemEmbedded systembusinessSynchronous motor
researchProduct

Comparative Study of the Loads Acting on the Operating Cardanic Transmission in the Closed and Open Loop Configurations

2015

On the basis of a comparative study, this paper aims to determine the maximum loads that can occur in operating conditions on the cardanic transmission assembly of motor vehicles in the open or closed loop configurations. The research is conducted under static conditions using finite elements and shows the components with their maximum values obtained in normal operating conditions.

EngineeringTransmission (telecommunications)Basis (linear algebra)business.industryOpen-loop controllerGeneral MedicineStructural engineeringbusinessClosed loopFinite element methodApplied Mechanics and Materials
researchProduct