Search results for "Converters"
showing 10 items of 140 documents
A new current-mode control for DC/DC converter
2005
Current-sensing is used widely in smart power chips, especially in DC/DC converter for voltage regulator modules (VRM), implemented with interleaved synchronous rectifier buck converters. The interleaved technique main difficulty is due to its current-sharing control between the several modules. Besides, if the used control technique is current-mode type, it is necessary create a ramp signal proportional to current on the inductor. In this paper, a lossless current-sensing method, solving the major disadvantages of the current-mode control and implementing a current-sharing technique, is proposed. This innovative technique is tested in a two-module interleaved buck converter.
A High-Efficiency, Low-Cost Solution for On-Board Power Converters
2012
Wide-input, low-voltage, and high-current applications are addressed. A single-ended isolated topology which improves the power efficiency, reduces both switching and conduction losses, and heavily lowers the system cost is presented. During each switching cycle, the transformer core reset is provided. The traditional tradeoff between the maximum allowable duty-cycle and the reset voltage is avoided and the off-voltage of active switches is clamped to the input voltage. Therefore, the system cost is heavily reduced and the converter is well suited for wide-input applications. Zero-voltage switching is achieved for active switches, and the power efficiency is greatly improved. In the output …
An improved Flyback converter
2009
This paper presents a modified Flyback converter able to operate with higher efficiency and smaller size, overcoming most of the conventional flyback converter drawbacks, and also keeping its low cost and simplicity. In particular, the proposed converter allows the mosfet off voltage to be reduced and clamped to the input, thus recovering the transformer leakage energy. As a consequence, the duty cycle can be extended to unity, thus reducing the voltage stress across the output rectifier, and lowering both the magnetizing inductance and the transformer bias current values. In addition, due to the auxiliary mosfet, the magnetizing current can become negative, eliminating the discontinuous co…
A high-efficiency regulation technique for a zero-voltage zero-current power switching converter
1998
This paper describes the application of a new regulation technique to a resonant converter that features zero-voltage (ZV) and zero-current (ZC) switching and works at constant frequency and duty cycle. The regulator utilizes the concept of regulating only a percentage of the total power in a bidirectional manner, thus allowing the converter to be optimized for both mass and efficiency. The proposed regulation technique has a wide range of applicability to almost all types of power converters or inverters that utilize a transformer to produce an isolated output. By using the concept of addition or subtraction of AC voltages, a fully regulated output voltage is achieved. The resultant effect…
Digital power conversion system based on a sigma-delta modulator linear model
2005
This paper presents a new linear model for the sigma-delta (/spl Sigma//spl Delta/) modulator, based on modeling the nonlinear quantizer with a linear factor, and its input-to-output transfer function is given. The use of a 1-bit sigma-delta modulator in DC/DC power converter systems permits to implement a complete digital control. Results of an investigation from a prototype for a DC-DC converter are here reported. Using of a field programmable gate array allows implementing a simple variable control function. The modulator output produces a variable-frequency variable duty-ratio signal to control the switching power transistors.
A demagnetization circuit for forward converters
2009
This paper presents a demagnetization circuit able to operate the forward converter with an higher efficiency and with a wider input range. In particular, by the means of few added components, the magnetizing energy and the leakage one are continuously recovered, and the transformer reset and the primary mosfet OFF voltage clamp to the input, both under steady state and transient operations, are provided. The reduced voltage stress allows the converter to operate with a duty extended to unity over the typical 70% limit of the Active Clamp topology, with smaller output inductance, better converter dynamics and wider input range. Furthermore, thanks to this technique, by employing a duty appr…
Linear-non-linear digital control for dc/dc converters with fast transient response
2009
A linear-non-linear digital control for multi-module DC/DC converters that improves system stability, solves the limit-cycle problem, reduces recovery time and limits over- and under-shoots in regulated output voltage, is presented. A simulation model in Matlab-Simulink/Active-HDL mixed environment is described. Preliminary hardware tests on a single-phase step-down converter are reported. Simulation and experimental results are shown.
DC/DC converter topologies for electrolyzers: State-of-the-art and remaining key issues.
2017
In recent years, the use of electrolyzers to produce cleanly and efficiently hydrogen from renewable energy sources (i.e. wind turbines, photovoltaic) has taken advantage of a growing interest from researchers and industrial. Similarly to fuel cells, DC/DC converters are needed to interface the DC bus with the electrolyzer. Usually, electrolyzers require a low DC voltage to produce hydrogen from water. For this reason, a DC/DC buck converter is generally used for this purpose. However, other DC/DC converter topologies can be used depending on the feature of the electrolyzer and electrical grid as well. The main purpose of this paper is to present the current state-of-the-art of DC/DC conver…
DSP Implementation for Measuring the Loop Gain Frequency Response of Digitally Controlled Power Converters
2012
This paper presents a method for measuring the loop gain frequency response of digitally controlled power converters, without the need of any expensive measurement equipment such as frequency response analyzers (FRA). The method is based on the traditional perturbation and measurement scheme. The perturbation is internally synthesized by the DSP and applied as pulse-width modulation to the converter. The loop input and output data are sent to a PC via universal serial bus, which performs online the DFT of sent data. The perturbation amplitude is varied with frequency to improve signal-to-noise ratio of measurements. The number of cycles used to perform discrete Fourier transform calculation…
Four-Level Three-Phase Inverter With Reduced Component Count for Low and Medium Voltage Applications
2021
This paper proposes a novel three-phase topology with a reduced component count for low- and medium-voltage systems. It requires three bidirectional switches and twelve unidirectional switches for producing four-level voltages without using flying capacitors or clamping diodes, reducing the size, cost, and losses. Removing flying capacitors and clamping diodes allows it to simplify control algorithms and increase the reliability, efficiency, and lifetime. A modified low-frequency modulation (LFM) scheme is developed and implemented on the proposed topology to produce a staircase voltage with four steps. Further, a level-shifted pulse width modulation (LSPWM) is used to reduce the filter siz…