Search results for "Cooling"
showing 10 items of 470 documents
Size Dependence of Tracer Diffusion in Supercooled Liquids
1996
We have determined by forced Rayleigh scattering the diffusion coefficients D of several photochromic tracers with van der Waals radii between 0.38 and 8 nm (the largest ones being photolabeled polystyrene micronetworks) in 10 glass-forming liquids at temperatures between the glass temperature Tg and ∼1.2Tg. The results were analyzed in terms of power law plots, D(T) ∝ T/η(T)ξ, where η is the solvent shear viscosity, and temperature shifts, D(T) ∝ T/η(T + ΔT). The shift ΔT was related with the width of the rotational correlation time distribution via the time−temperature superposition principle.
2016
This commentary describes important findings of the article published by Sheroziya and Timofeev in The Journal of Neuroscience in 2015. The authors use moderate cortical temperature change, local cooling or heating of somatosensory cortex, to modulate excitable states of the brain. These changes, under physiological conditions, result from neuromodulation, as well as other network effects. They report that cooling disrupts thalamocortical slow oscillations and induces an activated cortical state, while mild heating has the opposite effect and increases slow-wave rhythmicity. We evaluate these findings regarding their utility for inducing and investigating cortical state fluctuations, compar…
2021
We report on the thermodynamic, structural, and dynamic properties of a recently proposed deep eutectic solvent, formed by choline acetate (ChAc) and urea (U) at the stoichiometric ratio 1:2, hereinafter indicated as ChAc:U. Although the crystalline phase melts at 36–38 °C depending on the heating rate, ChAc:U can be easily supercooled at sub-ambient conditions, thus maintaining at the liquid state, with a glass–liquid transition at about −50 °C. Synchrotron high energy x-ray scattering experiments provide the experimental data for supporting a reverse Monte Carlo analysis to extract structural information at the atomistic level. This exploration of the liquid structure of ChAc:U reveals th…
Translational and rotational molecular motion in supercooled liquids studied by NMR and forced Rayleigh scattering
1994
It has been shown that translational diffusion coefficients, Dt, in the supercooled van der Waals liquids, orthoterphenyl, phenolphthaleindimethylether, and salol, have a weaker temperature dependence than the shear viscosity, η, at T ≲ 1.2Tg and can be described by Dt ∼ η−χ with χ < 1 whereas Dr ∼ η−1 applies for the mean rotational diffusion coefficients, Dr, down to the glass transition temperature, Tg. This apparent decoupling of translational and rotational motion has been discussed in relation with possible anomalous short time diffusion, spatial heterogeneity, and cooperative molecular motions close to Tg.
Energy performance evaluation of a demo solar desiccant cooling system with heat recovery for the regeneration of the adsorption material
2012
Abstract Since July 2008, a Solar Desiccant Evaporative Cooling (DEC) system has been operating as a test plant at the solar laboratory of the Dipartimento di Energia (ex DREAM) of the University of Palermo. The system is composed of an air handling unit (AHU) designed for ventilation of the laboratory coupled with a radiant ceiling that provides most of the required sensible cooling/heating energy. Flat plate collectors deliver part of the regeneration heat of the desiccant wheel during the summertime and are used for space heating during the wintertime. The system was designed for high humidity loads because of the typical climate conditions at the site and the need to support a radiant c…
A Validation Methodology for a Combined Heating Cooling and Power (CHCP) Pilot Plant
2004
A great number of variables significantly influence the energetic, environmental and economic results of CHP (Combined Heating and Power) and CHCP (Combined Heating Cooling and Power) plants operation, and as a consequence their project activity is rather complex. In order to select the best layout and properly size the machines, detailed data on hourly electric, thermal, and cooling demand are necessary, so that a series of plant life cycle simulations may have to be carried out. Unfortunately, such detailed data are rarely available, because energy consumptions data for existing buildings are usually derived from aggregated monthly or bimonthly gas and electricity bills. Even more difficu…
Life Cycle Assessment Performance Comparison of Small Solar Thermal Cooling Systems with Conventional Plants Assisted with Photovoltaics
2012
Abstract Life Cycle Assessment (LCA) allows for the consideration of energy consumption and environmental impacts associated with all the stages of a product's life, from the cradle to the grave . Starting from the results obtained in the IEA SHC Task 38 framework for the LCA of small solar assisted heat driven chillers, the application of such methodology has been extended to systems with a conventional compression chiller assisted by a photovoltaic plant. This study aims to provide a more comprehensive investigation through a comparison of these two families of solar assisted cooling systems (with solar thermal or PV), which is an important topic for studies concerning the research of eff…
Characterization of cooling loads in the wine industry and novel seasonal indicator for reliable assessment of energy saving through retrofit of chil…
2020
Abstract The food sector is a major consumer of energy and growing efforts are being made in the search for solutions that will guarantee the efficient and sustainable use of energy resources. Among the different sectors, wineries are attracting particular interest due to the continuous growth of the global market and production. Surveys conducted in the winemaking sector have highlighted the importance of performing accurate energy audits and have identified the installation of efficient refrigeration systems as a promising solution in a variety of cases. Unfortunately, the savings achievable by efficient cooling technologies are often estimated using simplified approaches which do not tak…
Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in…
2009
Abstract This paper presents a detailed analysis of the energy and economic performance of desiccant cooling systems (DEC) equipped with both single glazed standard air and hybrid photovoltaic/thermal (PV/t) collectors for applications in hot and humid climates. The use of ‘solar cogeneration’ by means of PV/t hybrid collectors enables the simultaneous production of electricity and heat, which can be directly used by desiccant air handling units, thereby making it possible to achieve very energy savings. The present work shows the results of detailed simulations conducted for a set of desiccant cooling systems operating without any heat storage. System performance was investigated through h…
Energy balance and life cycle assessment of small size residential solar heating and cooling systems equipped with adsorption chillers
2017
Abstract Solar heating and cooling systems for space heating and cooling are experiencing a growing trend and interest. However, the actual energy and environmental performance of small/medium size installations is not clearly foreseeable. In this paper, an analysis of such systems using adsorption chillers in different European climates is presented. Solar systems have been simulated in TRNSYS and compared to a conventional system employing a vapour compression unit. The results have been used for a Life Cycle Assessment (LCA) study, determining the potential impact during the whole life of the system, from raw materials supply to its end-of-life. The LCA has been carried out by using the …