Search results for "Coordinate system"
showing 10 items of 118 documents
A local picture associated with a triply degenerate vibrational mode: vibrational and rovibrational local states
1998
International audience; Abstract: A symmetrized basis adapted to the study of some vibrational excited states of spherical top molecules is proposed. This basis, consistent with the Cartesian picture associated with a three-dimensional mode, is then tested numerically through various XY6 and XY4 molecules. In addition, some simulations, made with 238UF6 and a simplified version of an effective Hamiltonian, clearly show that the method can be further extended through the construction of a symmetrized local rovibrational basis.
Dosimetric characteristics of the CDC-type miniature cylindrical 137Cs brachytherapy sources
2002
The low dose rate CDC-type miniature cylindrical 137 Cs sources are available, with one or three active beads, for use in source trains in automatic and manual afterloading systems for gynecological brachytherapy. Absolute dose rate distributions in water have been calculated around these sources using the Monte CarloGEANT3 code and they are presented as conventional two-dimensional Cartesian lookup tables. The AAPM Task Group 43 formalism for dose calculation has been also applied. The dose rate constant obtained for the one bead source is Λ=1.113±0.003 cGyh −1 U −1 , and the value for the three bead source is Λ=1.103±0.003 cGyh −1 U −1 . Finally, for the treatment planning systems based o…
Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: evaluation of applicator attenuation and superposition approximation effe…
2004
The purpose of this study is to calculate the dose rate distribution for the Amersham Cs-137 pellet source used in brachytherapy with the Selectron low-dose-rate remote afterloading system in gynaecological applications using the Monte Carlo code GEANT4. The absolute dose rate distribution for the pellet source was obtained and presented as a one-dimensional absolute dose rate table as well as in the Task Group 43 dose-calculation formalism. In this study, excellent agreement was found between the point source theoretical model using fitted polynomial values and Monte Carlo calculations of the dose rate distribution for the pellet source. A comparison study was also made between the dose ra…
An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributio…
2009
Certain brachytherapy dose distributions, such as those for LDR prostate implants, are readily modeled by treatment planning systems (TPS) that use the superposition principle of individual seed dose distributions to calculate the total dose distribution. However, dose distributions for brachytherapy treatments using high-Z shields or having significant material heterogeneities are not currently well modeled using conventional TPS. The purpose of this study is to establish a new treatment planning technique (Tufts technique) that could be applied in some clinical situations where the conventional approach is not acceptable and dose distributions present cylindrical symmetry. Dose distributi…
MO-D-AUD B-08: Treatment Planning for Complex Brachytherapy Dose Distributions Using High-Z Shields and Conventional Software
2008
Purpose: Certain brachytherapydose distributions, like for LDR prostate implants, are readily modeled by treatment planningsoftware using the superposition principle of individual seeds to replicate the total dose distribution. However, dose distributions for brachytherapy treatments using high‐Z shields are currently not well‐modeled using conventional software.Method and Materials:Dose distributions from complex brachytherapy plaques determined using Monte Carlo methods were used as input data, and included COMS‐based eye plaques using 125 I , 103 Pd , and 131 Cs ; 4–8cm diameter AccuBoost peripheral breast brachytherapy applicators from Advanced Radiation Therapy; and the 2 and 3cm diame…
Polar coordinates in Taekwondo
2016
[EN] In observational methodology, inter‐relational behaviors are relevant for coaches and athletes to know which behaviors are dependent or inexistent while others occur.
Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus 192Ir sources.
2001
In this study a complete set of dosimetric data for the GammaMed high dose rate (HDR) 12i and Plus 192 Ir sources are presented. These data have been calculated by means of the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water are presented as conventional two dimensional (2D) Cartesian look-up tables, and in the TG43 formalism.
Accuracy of stereotactic coordinate transformation using a localisation frame and computed tomographic imaging
1999
The accuracy of coordinate transformation from the computed tomographic (CT) space to the stereotactic frame space was analysed for frame-based stereotactic systems which use a localisation frame and coordinate transformation based on matrix calculation. The coordinate transformation was divided into three consecutive steps: (1) transforming the localisation frame into the CT image built up from pixels with distinct attenuation values, (2) determining the rod centres of the localisation frame in the CT image, and (3) coordinate transformation from the image to the frame space using the centres of the rods in the image space and algebraic, matrix-based calculation. The error contribution at …
Reconstructing the free-energy landscape of Met-enkephalin using dihedral principal component analysis and well-tempered metadynamics
2013
Well-Tempered Metadynamics (WTmetaD) is an efficient method to enhance the reconstruction of the free-energy surface of proteins. WTmetaD guarantees a faster convergence in the long time limit in comparison with the standard metadynamics. It still suffers however from the same limitation, i.e. the non trivial choice of pertinent collective variables (CVs). To circumvent this problem, we couple WTmetaD with a set of CVs generated from a dihedral Principal Component Analysis (dPCA) on the Ramachadran dihedral angles describing the backbone structure of the protein. The dPCA provides a generic method to extract relevant CVs built from internal coordinates. We illustrate the robustness of this …
Conversion of Dupin Cyclide Patches into Rational Biquadratic Bézier Form
2005
This paper uses the symmetry properties of circles and Bernstein polynomials to establish a series of interesting barycentric properties of rational biquadratic Bezier patches. A robust algorithm is presented, based on these properties, for the conversion of Dupin cyclide patches into Bezier form. A set of conversion examples illustrates the use of this algorithm.