Search results for "Coronary angiography"
showing 10 items of 308 documents
High Iodine Concentration Contrast Material for Noninvasive Multislice Computed Tomography Coronary Angiography
2006
OBJECTIVE: The objective of this study was to compare intracoronary attenuation on 16-row multislice computed tomography (16-MSCT) coronary angiography using 2 contrast materials (CM) with high iodine concentration. MATERIAL AND METHODS: Forty consecutive patients (29 male, 11 female; mean age, 61 ± 11 years) with suspected coronary artery disease were randomized to 2 groups to receive 100 mL of either iopromide 370 (group 1: Ultravist 370, 370 mg iodine/mL; Schering AG, Berlin, Germany) or iomeprol 400 (group 2: Iomeron 400, 400 mg iodine/mL; Bracco Imaging SpA, Milan, Italy). Both CM were administered at a rate of 4 mL/s. All patients underwent 16-MSCT coronary angiography (Sensation 16; …
Autosomal recessive hypercholesterolemia in a Sicilian kindred harboring the 432insA mutation of the ARH gene
2003
Abstract We describe a Sicilian family presenting a recessive form of hypercholesterolemia harboring a mutation of the autosomal recessive hypercholesterolemia (ARH) gene. In two of the three sibs, a 26-year-old male and a 22-year-old female, a severe hypercholesterolemia was diagnosed with very high levels of plasma cholesterol (15.9 and 12.2 mmol/l, respectively); tendon xanthomatas and xanthelasms were present and in the male proband was documented a diffuse coronary atherosclerotic disease with a rapid and fatal progression. Both the parents had normal or slightly increased levels of plasma cholesterol. All causes of secondary hypercholesterolemia were ruled out as well as an involvemen…
High frequency rotational ablation: an alternative in treating coronary artery stenoses and occlusions.
1993
OBJECTIVE--To prove the safety and effectiveness of high frequency rotational ablation of coronary artery stenoses and occlusion in humans. SUBJECTS--106 patients with symptoms (91 men, 15 women) who had 67 significant stenoses, mainly types B and C, and 46-chronic occlusions. MAIN OUTCOME MEASURES--Mean change in diameter stenosis after rotational angioplasty alone and in combination with percutaneous transluminal coronary angioplasty immediately after treatment and 24 hours and six months later; restenosis rates at six months; complication of treatment. RESULTS--Rotational ablation could not be used in five stenoses and 16 chronic occlusions because of inability to reach or cross the lesi…
Fragment reconstruction of coronary arteries using transesophageal echocardiography for coronary diagnostics
2008
Aims Ultrasound differs procedurally from the established methods for non-invasive coronary visualization and is therefore an interesting alternative for non-invasive diagnostics. In this study, fragment reconstruction of coronary arteries by transesophageal echocardiography (FRC-TEE) was investigated for the first time in a patient population being evaluated for coronary angiography. Methods and results Ultrasonic and angiographic findings were compared visually and using quantitative measurements in 50 patients. One hundred and seventy-one vessels were examined by FRC-TEE. The total lengths visualized were 9.6+ 1.7 cm for the right coronary artery, 7.0+ 1.1 cm for left circumflex, 3.9+ 1.…
Non-Invasive Assessment of Coronary Artery Bypass Grafts and Native Coronary Arteries Using 64-Slice Computed Tomography: Comparison With Invasive Co…
2010
Introduction and objectives Although the diagnostic accuracy of CT in the non-invasive assessment of coronary arteries and grafts is known to be high, only a few studies have investigated the technique's reliability for the combined assessment of native coronary arteries, grafts, and vessels lying distal to anastomoses. The aim of this study was to evaluate the diagnostic accuracy of 64-slice CT for assessing coronary grafts and native coronary arteries. Methods In the study, 64-slice CT was used to evaluate 36 patients who had undergone coronary artery bypass graft surgery and had a clinical indication for angiographic graft assessment. The diagnostic accuracy of CT for identifying signifi…
Influence of heart rate in the selection of the optimal reconstruction window in routine clinical multislice coronary angiography
2008
Purpose. The aim of our study was to assess the influence of heart rate on the selection of the optimal reconstruction window with 40-slice multidetector-row computed tomography (40-MDCT) coronary angiography. Materials and methods. We studied 170 patients (114 men, age 60 +/- 11.3 years) with suspected or known coronary artery disease with 40-MDCT coronary angiography. Patients [mean heart rate (HR) 62.9 +/- 9.3 bpm, range 42-94 bpm] were clustered in two groups (group A: HR <= 65 bpm; group B: HR >65 bpm). Multiphase reconstruction data sets were obtained with a retrospective electrocardiogram (ECG)-gated 40-MDCT coronary angiography scan from 0% to 95% every 5% of the R-R interval.…
Serum uric acid as an independent predictor of mortality in patients with angiographically proven coronary artery disease.
2002
It is a matter of controversy as to whether uric acid is an independent predictor of mortality in patients with coronary artery disease (CAD) or whether it represents only an indirect marker of adverse outcome by reflecting the association between uric acid and other cardiovascular risk factors. Therefore, we studied the influence of uric acid levels on mortality in patients with CAD. In 1,017 patients with angiographically proven CAD, classic risk factors and uric acid levels were determined at enrollment. A follow-up over a median of 2.2 years (maximum 3.1) was performed. Death from all causes was defined as an end point of the study. In CAD patients with uric acid levels303 micromol/L (5…
Elevated monocyte chemoattractant protein-1 serum levels in patients at risk for coronary artery disease.
2005
Background Monocyte chemoattractant protein-1 (MCP-1) is involved in the recruitment of monocytes into the arterial vessel wall as one of the major events leading to atherosclerotic vascular diseases, such as coronary artery disease (CAD). Methods and Results The study group comprised 263 volunteers aged between 18 and 85 years who were admitted to hospital or clinic for scheduled invasive and non-invasive diagnostic procedures. MCP-1 serum levels were determined using a sandwich-enzyme-linked immunosorbent assay. In each patient, the coronary risk factors (CRF), such as hypertension, high cholesterol, diabetes mellitus, obesity, positive family history, and smoking were evaluated. Low-dens…
Prognostic significance of repetitive ventricular response in chronic coronary artery disease.
1985
A prospective study was conducted in 267 patients with angiographically defined coronary artery disease without documented ventricular tachycardia to determine the prognostic significance of repetitive ventricular response (RVR) after programmed electrical stimulation (PES). The patients were classified inducible if RVR with 3 or more echo beats (RVR greater than or equal to 3) could be induced. 89 patients without previous myocardial infarction (MI), 61 survivors of MI occurring between 6 weeks and 3 months before and 117 patients who had survived longer than 3 months after MI were studied. A standardized stimulation protocol with single (S1S2) and double (S1S2S3) extrastimuli during ventr…
Detection of coronary artery calcifications predicting coronary heart disease: comparison of fluoroscopy and spiral CT.
1998
The aim of this study was to evaluate the clinical relevance of coronary artery calcifications detected by spiral CT, congruence with fluoroscopy (FS) and coronary angiography, and comparison with studies reporting on application of double-helical CT and ultrafast CT. Forty patients underwent spiral CT (2-mm slice thickness, table feed 3 mm/s), coronary angiography, and FS (performed in the usual manner). Stenosis and calcifications were evaluated semiquantitatively. Nineteen patients suffering from a stenosis ≥ 75 % were verified at coronary angiography. All had coronary artery calcification on spiral CT. Fluoroscopy did not detect 8 of 19 patients with a stenosis ≥ 75 % (1 vessel: n = 1; …