Search results for "Correction"
showing 10 items of 601 documents
Accuracy of four digital scanners according to scanning strategy in complete-arch impressions.
2018
STATEMENT OF PROBLEM:Although there are specific and general digital scanning guidelines depending on the system used, it is important to have the necessary flexibility in the acquisition of three-dimensional (3D) images to adapt to any clinical situation without affecting accuracy. PURPOSE:The purpose of this in vitro study was to identify and compare the scanning strategy with the greatest accuracy, in terms of trueness and precision, of four intraoral scanners in the impression of a complete dental arch. MATERIAL AND METHODS:Four digital scanners were evaluated with a 3D measuring software, using a highly accurate reference model obtained from an industrial scanner as a comparator. Four …
Analysis of the atmospheric and emissivity influence on the splitwindow equation for sea surface temperature
1994
Abstract In this paper we have analysed the effects of the different atmospheric species (water vapour, fixed gases and aerosols) and the surface emissivity on the split-window method for determining the sea surface temperature. The widely used split-window method is based on the differential absorption of water vapour in the atmospheric window 10.5ndash;12.5 μm. Other atmospheric species with absorption coefficients different to that of water vapour can then have a large influence on the split-window. The effect of gases, such as C02, N20, CH4, CO and 03, and maritime aerosols is evaluated by comparing the effect of the water vapour alone. To do this we simulated AVHRR measurements in chan…
Measurement of the forward-backward asymmetry of e(+)e(-)-]z-]b(b)over-bar using prompt leptons and a lifetime tag
1995
The forward-backward asymmetry of the process e+e-→Z→b {Mathematical expression} has been measured using events collected by the DELPHI experiment during the 1991 and 1992 LEP runs. This data sample corresponded to 884 000 hadronic Z decays at a centre-of-mass energy {Mathematical expression}. The tagging of b-quark events was performed using two approaches; the first was based on the semileptonic decay channels b→X+μ and b→X+e, the second used a lifetime tag with jet-charge reconstruction. The results of these two methods were combined to give {Mathematical expression} With the semileptonic sample, the forward-backward asymmetry of the process e+e-→Z→ {Mathematical expression} was also mea…
Time Series Corrections and Analyses in Thermal Remote Sensing
2013
The time span of surface thermal data bases now reaches a few decades. However, studies using surface thermal time series are seldom, due to the difficulty of obtaining temporally coherent estimations for this parameter. Applications for surface thermal multitemporal analysis range from climate change studies and modeling to anomaly detection for natural or industrial hazard detection. This chapter presents methods to improve the temporal coherence of temperature time series, through data reconstruction of atmospheric and cloud contaminated observations, and through the correction of the orbital drift effect which hinders the use of the longest data sets. Then, methods for the analysis of t…
On the variation of the correction factor of surface velocity with the measurement vertical for shallow flows over rough beds
2023
Considering that water flow energy affects the detachment of soil particles, the transport and deposit of the detached particles, the flow velocity is a key variable governing the soil erosion processes at the hillslope scale. The simple dye-tracer technique for measuring mean flow velocity can be applied in non-controlled field applications for which some measurement difficulties (e.g. due to sediment transport, and shallow flows) can occur. The correction factor is usually obtained as the ratio between the mean velocity, deriving from measurements of flow discharge and water depth, and surface velocity. Alternatively, the possibility of using the velocity profile in a given vertical to de…
Charge loss correction in CZT pixel detectors at low and high fluxes: analysis of positive and negative pulses
2018
Charge losses are typical drawbacks in cadmium–zinc–telluride (CZT) pixel detectors. The effects of these phenomena are strongly related to the interaction point of the photons and are more severe for photon interactions at the inter-pixel gap and near the pixelated anode. In this work, we present some original techniques able to correct charge losses in pixelated CZT detectors at both low and high fluxes. The height, the shape and the arrival time of collected- and induced-charge pulses with both positive and negative polarities are analysed to recover charge losses after the application of charge sharing addition (CSA). Sub-millimetre CZT pixel detectors, fabricated by different manufactu…
Homomorphic Approach to RF-Inhomogeneity Removal Based on Gabor Filter
2007
In this paper a bias correction algorithm for magnetic resonance imaging (MRI) is presented. The magnetic resonance (MR) images affected by this artifact, also called RF-inhomogeneity, exhibit irregular spatial brightness variations caused by magnetic field inhomogeneity. Here we present an original algorithm based on E2D - HUM, already proposed by some of the authors, where a modified Gabor filter is introduced in the elaboration chain to provide directional capabilities to suppress the artifact. The process of restoration doesn't care about the structure of the image and it has been applied to MR images of different parts of body like knee, abdomen, pelvis and brain. A comparison with oth…
Color Correction for Image Stitching by Monotone Cubic Spline Interpolation
2015
This paper proposes a novel color correction scheme for image stitching where the color map transfer is modelled by a monotone Hermite cubic spline and smoothly propagated into the target image. A three-segments monotone cubic spline minimizing color distribution statistics and gradient differences with respect to both the source and target images is used. While the spline model can handle non-linear color maps, the minimization over the gradient differences limits strong alterations on the image structure. Adaptive heuristics are introduced to reduce the minimization search space and thus computational time. Experimental comparisons with respect to the state-of-the-art linear mapping model…
Metabolic impact of Partial Volume Correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment
2014
AIM: The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. METHODS: Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-I) and after (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated f…
Piecewise planar underwater mosaicing
2015
A commonly ignored problem in planar mosaics, yet often present in practice, is the selection of a reference homography reprojection frame where to attach the successive image frames of the mosaic. A bad choice for the reference frame can lead to severe distortions in the mosaic and can degenerate in incorrect configurations after some sequential frame concatenations. This problem is accentuated in uncontrolled underwater acquisition setups as those provided by AUVs or ROVs due to both the noisy trajectory of the acquisition vehicle — with roll and pitch shakes — and to the non-flat nature of the seabed which tends to break the planarity assumption implicit in the mosaic construction. These…