Time-resolved X-ray microtomographic measurement of water transport in wood-fibre reinforced composite material
2016
Natural fibre composites are prone to absorb moisture from the environment which may lead to dimensional changes, mold growth, degradation of mechanical properties or other adverse effects. In this work we develop a method for direct non-intrusive measurement of local moisture content inside a material sample. The method is based on X-ray microtomography, digital image correlation and image analysis. As a first application of the method we study axial transport of water in a cylindrical polylactic acid/birch pulp composite material sample with one end exposed to water. Based on the results, the method seems to give plausible estimates of water content profiles inside the cylindrical sample.…
3D displacement field measurement with correlation based on the micro-geometrical surface texture
2011
Image correlation methods are widely used in experimental mechanics to obtain displacement field measurements. Currently, these methods are applied using digital images of the initial and deformed surfaces sprayed with black or white paint. Speckle patterns are then captured and the correlation is performed with a high degree of accuracy to an order of 0.01 pixels. In 3D, however, stereo-correlation leads to a lower degree of accuracy. Correlation techniques are based on the search for a sub-image (or pattern) displacement field. The work presented in this paper introduces a new correlation-based approach for 3D displacement field measurement that uses an additional 3D laser scanner and a C…
Object tracking in medical imaging using a 2D active mesh system
2003
International audience; Abstract: This article proposes a technique for tracking moving organs in medical imaging. It can be split into two stages. We first initialize a 2D-triangular mesh on the first image of the sequence. We distinguish different objects of interest by grouping together the triangles that make them up. Afterwards, we deform this mesh on the successive images in order to track each identified object. The tracking stage uses optical flow by adding a node relaxation step to avoid mesh deteriorations. The mesh deformations analysis provides access to motion information along the sequence. This technique is applied to a cine-MRI sequences of the heart and allows the analysis …
Digital image correlation analysis of interfacial debonding properties and fracture behavior in concrete
2007
The use of digital image correlation (DIC) as a fracture mechanics tool is described, for two projects currently underway. The goal of the first project is to examine the bond between carbon fiber reinforced polymers (CFRP) and concrete substrates. The second project involves the interfacial transition zone (ITZ) of plain concrete, and the softening and fracture behavior of this region. For both projects, DIC allows for precise measurement of the surface displacements of the deforming materials. The resulting strain data are higher in resolution than is possible with other experimental techniques. For both projects, the DIC results are being used to determine bond constitutive laws, which w…
Time-resolved fluorescence and fourier transform infrared spectroscopic investigations of lateral packing defects and superlattice domains in composi…
2003
Time-resolved fluorescence and Fourier transform infrared spectroscopies were used to investigate the lateral organization of lipids in compositionally uniform and fully equilibrated 1-palmitoyl-2-oleoyl-phosphatidylcholine/cholesterol (POPC/CHOL) liposomes prepared by a recently devised low-temperature trapping method. Independent fluorescence decay lifetime and rotational dynamics parameters of diphenylhexatriene (DPH) chain-labeled phosphatidylcholine (DPH-PC) in these liposomes were recovered from the time-resolved fluorescence measurements as a function of cholesterol molar fraction (X(CHOL)) at 23 degrees C. The results indicate significantly greater lifetime heterogeneity, shorter av…
Calculation of size‐intensive transition moments from the coupled cluster singles and doubles linear response function
1994
Coupled cluster singles and doubles linear response (CCLR) calculations have been carried out for excitation energies and dipole transition strengths for the lowest excitations in LiH, CH+, and C4and the results compared with the results from a CI-like approach to equation of motion coupled cluster (EOMCC). The transition strengths are similar in the two approaches for single molecule calculations on small systems. However, the CCLR approach gives size-intensive dipole transition strengths, while title EOMCC formalism does not. Thus, EOMCC calculations can give unphysically dipole transition strengths, e.g., in EOMCC calculations on a sequence of noninteracting LiH systems we obtained a neg…
Toward computability of trace distance discord
2014
It is known that a reliable geometric quantifier of discord-like correlations can be built by employing the so-called trace distance. This is used to measure how far the state under investigation is from the closest "classical-quantum" one. To date, the explicit calculation of this indicator for two qubits was accomplished only for states such that the reduced density matrix of the measured party is maximally mixed, a class that includes Bell-diagonal states. Here, we first reduce the required optimization for a general two-qubit state to the minimization of an explicit two-variable function. Using this framework, we show next that the minimum can be analytically worked out in a number of r…
Discrete wavelet transform based multispectral filter array demosaicking
2013
International audience; The idea of colour filter array may be adapted to multi-spectral image acquisition by integrating more filter types into the array, and developing associated demosaicking algorithms. Several methods employing discrete wavelet transform (DWT) have been proposed for CFA demosaicking. In this work, we put forward an extended use of DWT for mul-tispectral filter array demosaicking. The extension seemed straightforward, however we observed striking results. This work contributes to better understanding of the issue by demonstrating that spectral correlation and spatial resolution of the images exerts a crucial influence on the performance of DWT based demosaicking.
Application of wavelet analysis to acoustic emission pulses generated by partial discharges
2004
The subject matter of this paper refers to the improvement of the acoustic emission (AE) method when used for detection, measurement and location of partial discharges (PDs) in oil insulation systems of power appliances. The detailed subject matter refers to the issues connected with the application of modern methods of digital processing of signals obtained during technical high-power measurements. The paper presents the results of measurements and analyses of the AE pulses generated in setups making the modeling of basic PD forms that can occur in oil insulations possible. The research concentrated mainly on the following types of PDs: point-plane, multipoint-plane, multipoint-plane with …
A non-stationary MIMO vehicle-to-vehicle channel model based on the geometrical T-junction model
2009
©2009 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. Article also available from publisher: http://dx.doi.org/10.1109/WCSP.2009.5371438 In this paper, we derive a non-stationary multiple-input multiple-output (MIMO) vehicle-to-vehicle (V2V) channel model from the geometrical T-junction model. The propagation environment is assumed to be extremely non-isotropic. The proposed channel model takes into account double…