Search results for "Crew"

showing 10 items of 93 documents

Influence of Biologically Oriented Preparation Technique on Peri-Implant Tissues; Prospective Randomized Clinical Trial with Three-Year Follow-Up. Pa…

2019

Purpose: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years of functional loading. Materials and methods: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (group GS); cemented crown without finishing line (biologically oriented preparation technique) (group GBOPT); and conventional cemented crown with finishing line (group GCC). After three years in function, clinical parameters (presence of keratinized mucosa, probing depths, bleeding on probing, and radio…

complicationsmedicine.medical_treatmentRadiographyBleeding on probingPeriDentistryProsthesisCrown (dentistry)Articlelaw.invention03 medical and health sciencesimplant-supported prosthesis0302 clinical medicineRandomized controlled triallaw0502 economics and businessmedicinebusiness.industry05 social sciencesSoft tissue030206 dentistryGeneral MedicineBOPTscrew-retainedbone loss and clinical parameterscemented050211 marketingImplantmedicine.symptombusinesssoft tissuesJournal of Clinical Medicine
researchProduct

4-Methyl-N-(4-methylpyridin-2-yl)-N-(3,4,5,6-tetrahydro-2H-pyran-4-yl)pyridin-2-amine

2016

In the title compound, C17H21N3O, the pyridine rings make a dihedral angle of 84.44 (5)°. In the crystal, a C—H...N interaction forms a chain of molecules propagating along the twofold screw axis.

crystal structureTertiary amine010405 organic chemistryChemistrytertiary amineGeneral MedicineCrystal structureDihedral angle010402 general chemistry01 natural sciences0104 chemical sciencesCrystalCrystallographychemistry.chemical_compoundScrew axisPyridinelcsh:QD901-999pyridinaminepalladium-catalysed arylaminationlcsh:CrystallographyIUCrData
researchProduct

Crystal structure and absolute configuration of (4S,5R,6S)-4,5,6-trihydroxy-3-methylcyclohex-2-enone (gabosine H)

2017

The absolute configuration of the title compound, determined as 4S,5R,6S on the basis of the synthetic pathway, was confirmed by single-crystal X-ray diffraction. The mol­ecule is formed by a substituted six-membered cyclo­hexene ring adopting an envelope conformation and substituted by carbonyl, methyl and hydroxyl groups. The supra­molecular structure is mainly built by a combination of O—H⋯O and weaker C—H⋯O hydrogen bonds.

crystal structurenatural productStereochemistryCrystal structure010402 general chemistry010403 inorganic & nuclear chemistry01 natural sciencesResearch Communicationschemistry.chemical_compoundChain (algebraic topology)Screw axisPerpendicularGeneral Materials ScienceEnvelope (waves)CrystallographyChemistryHydrogen bondAbsolute configurationGeneral ChemistryMitsunobu inversion reactionCondensed Matter Physics0104 chemical sciencesabsolute configurationCrystallographyQD901-999EnoneActa Crystallographica Section E Crystallographic Communications
researchProduct

Learning Curve in Surgical Treatment of Odontoid Fixation for a Series of Type II C2 Fractures

2019

The craniovertebral junction (CVJ) is a complex anatomical area upon which most of the motion of the upper cervical spine depends [1]. Because of its unique range of motion, the CVJ is subject to several types of traumatic injury; it has been shown that odontoid fractures are the most common ones in the general population and are the most common isolated spinal fractures [2]. Accounting for up to 18% of all cervical fractures, odontoid fractures are the most common ones in elderly patients [3], in whom they account for up to 60% of spinal cord injuries [4].

education.field_of_studymedicine.medical_specialtySettore MED/27 - Neurochirurgiabusiness.industryPopulationSpinal cordCervical spine030218 nuclear medicine & medical imagingSurgery03 medical and health sciencesFixation (surgical)0302 clinical medicinemedicine.anatomical_structureTraumatic injurymedicineC1–C2 articular screw Learning Curve C1–C2 instability Odontoid screw Type II odontoid fracture Aged Fracture Fixation Internal Bone Screws Odontoid Process Spinal Cord Injuries Treatment Outcome Spinal Fractures Humans Spinal FusionbusinessSurgical treatmentRange of motioneducation030217 neurology & neurosurgery
researchProduct

Subjective and Objective Outcomes of Ankle Joint Arthrodesis with Either Ilizarov or Internal Fixation

2021

After arthroplasty, arthrodesis of the ankle joint is the most common method to treat advanced ankle osteoarthritis. The goal of the study was to assess the subjective and objective outcomes in 2 different types of fixation for ankle joint arthrodesis. We retrospectively assessed 47 patients who had undergone ankle joint arthrodesis with fixation either via an Ilizarov apparatus (group 1) (n = 21) or cannulated screws (group 2) (n = 26). The outcomes were measured by: (1) the quantity of analgesics administered, (2) the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, (3) general patient satisfaction, (4) the patients' decision to undergo the same procedure given an…

external fixationsatisfactionOrthopedics and Sports MedicineSurgeryscrew fixationblood transfusionJournal of Foot & Ankle Surgery
researchProduct

In Silico Finite Element Modeling of Stress Distribution in Osteosynthesis after Pertrochanteric Fractures

2022

A stabilization method of pertrochanteric femur fractures is a contentious issue. Here, we assess the feasibility of rapid in silico 2D finite element modeling (FEM) to predict the distribution of stresses arising during the two most often used stabilization methods: gamma nail fixation (GNF) and dynamic hip screw (DHS). The modeling was based on standard pre-surgery radiographs of hip joints of 15 patients with pertrochanteric fractures of type A1, A2, and A3 according to the AO/OTA classification. The FEM showed that the stresses were similar for both GNF and DHS, with the medians ranging between 53–60 MPa and consistently lower for A1 than A3 fractures. Stresses also appeared in the fixa…

gamma naildynamic hip screw; finite element modeling; gamma nail; pain perception; pertrochanteric fracture; osteosynthesis; rehabilitationfinite element modelingGeneral Medicinedynamic hip screwpain perceptionosteosynthesispertrochanteric fracturerehabilitationJournal of Clinical Medicine
researchProduct

Comparative effectiveness of helicopter emergency medical services compared to ground emergency medical services

2013

Physician-staffed helicopter emergency medical services (HEMS) are a well-established component of prehospital trauma care in Germany. Reduced rescue times and increased catchment area represent presumable specific advantages of HEMS. In contrast, the availability of HEMS is connected to a high financial burden and depends on the weather, day time and controlled visual flight rules. To date, clear evidence regarding the beneficial effects of HEMS in terms of improved clinical outcome has remained elusive.Traumatized patients (Injury Severity Score; ISS≥9) primarily treated by HEMS or ground emergency medical services (GEMS) between 2007 and 2009 were analyzed using the TraumaRegister DGU® o…

inorganic chemicalsAdultMalemedicine.medical_specialtyEmergency Medical ServicesLetterTime FactorsCrewCritical Care and Intensive Care MedicineOddsYoung AdultTrauma CentersGermanyEmergency medical servicesmedicinepolycyclic compoundsHumansheterocyclic compoundsProspective StudiesBeneficial effectsAgedintegumentary systembusiness.industryMultiple TraumaAir AmbulancesAir AmbulancesMiddle Agedmedicine.diseaseSurvival RateEmergency medicineCommentaryObservational studyFemaleMedical emergencybusinessComposite effectDeveloped countryCritical Care
researchProduct

Screw fixation of radial head fractures: Compression screw versus lag screw—A biomechanical comparison

2009

Abstract Introduction Secondary loss of reduction and pseudarthrosis due to unstable fixation methods remain challenging problems of surgical stabilisation of radial head fractures. The purpose of our study was to determine whether the 3.0 mm Headless Compression Screw (HCS) provides superior stability to the standard 2.0 mm cortical screw (COS). Materials and methods Eight pairs of fresh frozen human cadaveric proximal radii were used for this paired comparison. A standardised Mason II-Fracture was created with a fragment size of 1/3 of the radial head's articular surface that was then stabilised either with two 3.0 mm HCS (Synthes) or two 2.0 mm COS (Synthes) according to a randomisation …

medicine.medical_specialtyBone ScrewsElbowWeight-BearingFracture Fixation InternalRandom AllocationFixation (surgical)CadaverFracture fixationCadavermedicineHumansGeneral Environmental ScienceOrthodonticsOsteosynthesisbusiness.industryBiomechanicsmedicine.diseaseBiomechanical PhenomenaSurgeryPseudarthrosismedicine.anatomical_structureGeneral Earth and Planetary SciencesRadius FracturesbusinessCadaveric spasmInjury
researchProduct

European vestibular experiments on the Spacelab-1 mission: 7. Ocular counterrolling measurements pre- and post-flight.

1986

The static ocular counterrolling (OCR) of the four scientific crew members in the first Spacelab mission was measured during baseline-data-collection before and after the flight of SL-1. It was presumed that the modification of otolithic responses during spaceflight will be reflected in specific changes of the OCR-gain on the first days after recovery. The magnitude of OCR was determined analysing colour-transparencies of subjects right eyes that were produced in different positions of lateral body tilt. In general, one subject did not show any changes at all; three subjects exhibited a significant decrease of OCR-gain after exposure to weightlessness, whereby differences could be found bet…

medicine.medical_specialtyMotion SicknessCrewAdaptation (eye)Otolithic membraneAudiologySpaceflightlaw.inventionOtolithic MembraneOpticslawMedicineHumansSaccule and UtricleVestibular systembusiness.industryWeightlessnessWeightlessnessGeneral NeuroscienceGenetic VariationReflex Vestibulo-Ocularmedicine.diseaseAdaptation PhysiologicalMotion sicknesssense organsbusinessTilt (camera)Experimental brain research
researchProduct

A new concept to treat lumbar spine stenosis in a mini invasive way.

2017

medicine.medical_specialtybusiness.industryBone ScrewsLumbosacral RegionBioinformaticsDecompression SurgicalLumbar spine stenosisNeurosurgical ProceduresMini invasive surgeryText miningSpinal StenosisMedicineHumansMinimally Invasive Surgical ProceduresSurgeryNeurology (clinical)RadiologybusinessJournal of neurosurgical sciences
researchProduct