Search results for "Critical"

showing 10 items of 3024 documents

Calculation of shear influences on the phase separation of polymer blends exhibiting upper critical solution temperatures

1994

Calculations were performed on the basis of a generalized Gibbs energy of mixing G γ, which is the sum of the Gibbs energy of mixing of the stagnant system and E s, the energy stored in the system during stationary flow. With increasing shear rate γ, the demixing temperatures shift to lower values (shear-induced mixing; diminution of the heterogeneous area), then to higher values (shear-induced demixing), and finally to lower values again before the effects fade out. The details of the rather complex phase diagrams resulting for a given shear rate are primarily determined by a band in the T/χ plane (χ = mole fraction) within which (∂2 E s/∂χ2) T UCST where they submerge. Bound to a suitable…

ChemistryThermodynamicsCondensed Matter PhysicsMole fractionMiscibilityGibbs free energyPhysics::Fluid DynamicsShear ratesymbols.namesakeUpper critical solution temperaturesymbolsGeneral Materials ScienceSolubilityShear flowPhase diagramRheologica Acta
researchProduct

Recent advances in on-line solid-phase pre-concentration for inductively-coupled plasma techniques for determination of mineral elements

2012

Abstract We provide a critical survey on recent progress in on-line solid-phase pre-concentration for inductively-coupled plasma (ICP)-based techniques for trace-level determination of metals. We highlight some of the useful solid-phase materials suitable for on-line separation and enrichment prior to ICP determination. We discuss different applications of the methods developed along with their analytical figures of merit. Finally, we sketch out future prospects in this field.

Chemistrybusiness.industryPhase (matter)Analytical chemistryCritical surveyFigure of meritInductively coupled plasmaPre concentrationProcess engineeringbusinessSpectroscopyAnalytical ChemistryTrAC Trends in Analytical Chemistry
researchProduct

Prophylaxe und Behandlung der postoperativen Übelkeit und des postoperativen Erbrechens mit Tropisetron

1997

Chemotherapymedicine.medical_specialtymedicine.drug_classbusiness.industryNauseamedicine.medical_treatmentPostoperative vomitingGeneral MedicineCritical Care and Intensive Care MedicineSurgeryAnesthesiology and Pain MedicineAnesthesiaEmergency MedicinemedicineVomitingAntiemeticTropisetronPostoperative nauseamedicine.symptomComplicationbusinessmedicine.drugAINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie
researchProduct

A critical assessment of methods for the determination of the shear stress amplitude in multiaxial fatigue criteria belonging to critical plane class

2015

Abstract Multiaxial high cycle fatigue criteria based on the critical plane approach necessitate unambiguous definitions of the amplitude and mean value of the shear stress (τa and τm) acting on the material planes. Four of the existing definitions relate the values of τa and τm to a geometrical element of the curve described by the tip of the shear stress vector (curve Ψ), respectively, the radius of the Minimum Circumscribed Circle, the Longest Chord, the Longest Projection, the diagonal of the Maximum Rectangular Hull (MRH). In this paper a critical assessment of the above definitions is proposed, focusing on that based on the concept of MRH, which is the most recently developed. The mai…

Chord (geometry)Plane (geometry)business.industryMultiaxial fatigueMechanical EngineeringDiagonalMathematical analysisRadiusStructural engineeringIndustrial and Manufacturing EngineeringProjection (linear algebra)Critical planeSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineAmplitudeMechanics of MaterialsModeling and SimulationShear stressMultiaxial fatigue shear stress amplitude critical plane circumscribed circle longest chord maximum projection rectangular hullGeneral Materials ScienceCircumscribed circleRectangular hullCircumscribed circlebusinessShear stress amplitudeMathematicsInternational Journal of Fatigue
researchProduct

Implementation of gradients of organic solvent in micellar liquid chromatography using DryLab®: Separation of basic compounds in urine samples

2014

In micellar liquid chromatography (MLC), chromatographic peaks are more evenly distributed compared to conventional reversed-phase liquid chromatography (RPLC). This is the reason that most procedures are implemented using isocratic elution. However, gradient elution may be still useful in MLC to analyse mixtures of compounds within a wide range of polarities, decreasing the analysis time. Also, it benefits the determination of moderately to low polar compounds in physiological fluids performing direct injection: an initial micellar eluent with a low organic solvent content, or a pure micellar (without surfactant) solution, will provide better protection of the column against the proteins i…

Chromatography Reverse-PhaseChromatographyChemistryElutionChemical polarityAdrenergic beta-AntagonistsOrganic ChemistryAnalytical chemistryGeneral MedicineBiochemistryAnalytical ChemistrySurface-Active Agentschemistry.chemical_compound1-PropanolColumn chromatographyPulmonary surfactantMicellar liquid chromatographyCritical micelle concentrationSolventsHumansIndicators and ReagentsAnalytical proceduresMicellesSoftwareJournal of Chromatography A
researchProduct

Interaction of polyelectrolytes with oppositely charged micelles studied by fluorescence and liquid chromatography

2005

It is studied by spectrofluorimetry the association of ionized cationic micelles (cetyltrimethylammonium bromide, CTAB) with oppositely charged polyelectrolyte [sodium poly(styrenesulfonate), PSSNa]. CTAB provokes a change in the fluorescence intensity emitted by PSSNa. The investigated surfactants form micelle-like aggregates before critical micellar concentration (CMC). Two approaches (binding and partition equilibrium) are used to obtain the association constant, KA, number of CTAB molecules in a binding site, N, and apparent partition coefficient, Γ. Analysis of the parameters as a function of polymer concentration and ionic strength μ is performed. The effect of μ shows an enhancement …

ChromatographyAqueous solutionPolymers and PlasticsChemistryOrganic ChemistryGeneral Physics and AstronomyMicellePolyelectrolytePartition coefficientchemistry.chemical_compoundBromideIonic strengthPartition equilibriumCritical micelle concentrationMaterials ChemistryEuropean Polymer Journal
researchProduct

Compared effects of synthetic and natural bile acid surfactant on xenobiotic absorption. II. Studies with sodium glycocholate to confirm a hypothesis

1994

Abstract The effects of sodium glycocholate (SGC) on the intestinal absorption of drug-related xeriobiotics are investigated, on the basis of previously established absorption/partition relationships. Six phenylalkylcarboxylic acids, closely related to nonsteroid anti-inflammatory drugs in structure and constituting a true homologous series, were used as test compounds through an in situ rat gut technique, using the whole colon as nonspecialized absorption membrane model. Whereas the synthetic surfactants (i.e., polysorbates and laurylsulphates) at the critical micelle concentration have been shown to disrupt the aqueous boundary layer adjacent to the membrane, SGC does not; in contrast, it…

ChromatographyBile acidmedicine.drug_classSodiumPharmaceutical Sciencechemistry.chemical_elementMicelleIntestinal absorptionchemistry.chemical_compoundchemistryCritical micelle concentrationLipophilicitymedicineAbsorption (chemistry)XenobioticInternational Journal of Pharmaceutics
researchProduct

Influence of the addition of modifiers on solute-micelle interaction in hybrid micellar liquid chromatography

1998

In reversed-phase micellar liquid chromatography (MLC) organic modifiers are usually added to the mobile phase to modify the eluent strength and to increase the efficiency of the chromatographic peaks. The effect of the modifiers methanol, ethanol, 1-propanol, 1-butanol, 1-pentanol, acetonitrile and tetrahydrofuran on the critical micelle concentration (cmc) of the anionic surfactant sodium dodecylsulphate (SDS) has been studied to enable understanding of the interactions between solute, micelles and bulk liquid in such hybrid eluents. Methanol, acetonitrile and tetrahydrofuran increased thecmc, whereas the other alcohols reduced its value. For butanol and pentanol, which partition into the…

ChromatographyButanolOrganic ChemistryClinical BiochemistryThermodynamics of micellizationAlcoholBiochemistryMicelleMicellar electrokinetic chromatographyAnalytical Chemistrychemistry.chemical_compoundchemistryPulmonary surfactantMicellar liquid chromatographyCritical micelle concentrationChromatographia
researchProduct

Near-critical carbon dioxide extraction and liquid chromatography determination of UV filters in solid cosmetic samples: A green analytical procedure

2005

Near-critical carbon dioxide extraction of four UV filters used as sunscreens in lipsticks and makeup formulations is reported. Extraction parameters were optimized. Efficient recoveries were obtained after 15 min of dynamic extraction with a 80:20 CO2/ethanol mixture at 300 atm and 54 degrees C, using a 1.8 mL/min flow rate. Extracts were collected in ethanol, and appropriately diluted with ethanol and 1% acetic acid to obtain a 70:30 v/v ethanol/1% acetic acid solution. The four UV filters were determined by LC with gradient elution using ethanol/1% acetic acid as mobile phase. The accuracy of the analytical procedure was estimated by comparing the results with those obtained by methods b…

ChromatographyChemistryElutionExtraction (chemistry)Supercritical fluid extractionUV filterFiltration and SeparationCosmeticsCarbon DioxideHigh-performance liquid chromatographySupercritical fluidAnalytical ChemistryAcetic acidchemistry.chemical_compoundSample preparationSunscreening AgentsChromatography LiquidJournal of Separation Science
researchProduct

Study of polychlorinated biphenyls in street dust by supercritical fluid extraction-gas chromatography/mass spectrometry

1996

Street dust samples have been collected from highways, urban streets, a gasoline station, a pedestrian tunnel, and railway stations in some German cities. Nine polychlorinated biphenyls (PCBs from tri- to heptachlorobiphenyls) were quantitatively extracted by supercritical fluid extraction with CO2 at 200 bar and 40°C and analyzed by gas chromatography/mass spectrometry. The highest PCB loads (sum of the nine studied PCBs) of ca. 1 to 4 μg/g have been found in the samples from motorway A60 near Mainz, while in almost all other samples PCBs could be detected at only ca. 0.1 to 1 μg/g. At three sampling sites, a winter maximum of the PCB concentrations has been found.

ChromatographyChemistryEnvironmental chemistrySupercritical fluid extractionStreet dustGas chromatographyGas chromatography–mass spectrometryMass spectrometryBiochemistryWest germanyGasoline stationFresenius' Journal of Analytical Chemistry
researchProduct