Search results for "Currents"
showing 10 items of 87 documents
Ground-Fault Current Transfer at the Transition Station of a Combined Overhead-Cable Line. A Parametric Analysis
2007
When a substation is fed by a combined overhead-cable transmission line, a significant part of the ground fault current flows through the grounded cable sheaths and discharges into the earth at the transition station, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, the local ground electrode, small and of high resistance, could be inadequate to maintain the ground potential rise within safety limits in case of a fault to ground at the receiving end substation. Based on a circuit model approach, the paper presents a parametric analysis of the fault current distribution between the faulted substation and the transition station, ta…
A PC-based wattmeter for accurate measurements in sinusoidal and distorted conditions: Setup and experimental characterization
2012
This paper presents the development of a high-accuracy sampling wattmeter, which can be employed with both sinusoidal and distorted input signals. The proposed personal computer (PC)-based system is a simple, portable, and low-cost solution because it is based on two commercial data acquisition boards connected to a common PC. Owing to this solution, the voltage is sensed directly, avoiding expensive voltage dividers, while the current is sensed by means of a noninductive current shunt. Commercial software is also used for data processing and implementation of the virtual instrument. The setup of the PC-based wattmeter is described, with a detailed description of the correction strategy of …
Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion
2010
The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…
Characterization of clamp-on current transformers under nonsinusoidal conditions
2009
This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…
CALYPSO, a permanent and operational network of High-Frequency radar observing systems for real-time monitoring of surface currents in the Malta-Sici…
2014
Illegal migration often results in dramatic loss of lives that can be avoided with timely Search and Rescue (SAR) interventions; such SAR services require accurate information such as on sea-state and operational tools such as trajectory forecasting for floating objects at sea. The maritime transport of oil crossing this region accounts for 25% of the global maritime traffic and for nearly 7% of the world oil accidents over the last 25 years. In combination with localized oil extraction plants existing in the shelf zones this situation presents a serious threat to both the open-sea and coastal-zone habitats, with consequent impacts on local economic activities as tourism and fisheries, impa…
Differential branching fraction and angular analysis of the decay $B^{0} \to K^{*0} \mu^{+}\mu^{-}$
2013
The angular distribution and differential branching fraction of the decay B-0 -> K*(0)mu(+)mu(-) are studied using a data sample, collected by the LHCb experiment in pp collisions at root s = 7 TeV, corresponding to an integrated luminosity of 1.0 fb(-1). Several angular observables are measured in bins of the dimuon invariant mass squared, q(2). A first measurement of the zero-crossing point of the forward-backward asymmetry of the dimuon system is also presented. The zero-crossing point is measured to be q(0)(2) = 4.9 +/- 0.9 GeV2/c(4), where the uncertainty is the sum of statistical and systematic uncertainties. The results are consistent with the Standard Model predictions.
Kilohertz and Low-Frequency Electrical Stimulation With the Same Pulse Duration Have Similar Efficiency for Inducing Isometric Knee Extension Torque …
2017
International audience; Objective To test the hypotheses that, as compared with pulsed current with the same pulse duration, kilohertz frequency alternating current would not differ in terms of evoked-torque production and perceived discomfort, and as a result, it would show the same current efficiency.Design A repeated-measures design with 4 stimuli presented in random order was used to test 25 women: (1) 500-microsecond pulse duration, (2) 250-microsecond pulse duration, (3) 500-microsecond pulse duration and low carrier frequency (1 kHz), (4) 250-microsecond pulse duration and high carrier frequency (4 kHz). Isometric peak torque of quadriceps muscle was measured using an isokinetic dyna…
Distribution of Albian clastic deposits in the Benguela basin (Angola): evidence of a Benguela palaeocurrent?
2009
Abstract The Albian clastic Tuenza Formation of the Benguela basin (south Angola) is described and its geographic distribution analysed in detail. From these observations, the existence of an Albian “PalaeoBenguela current” is proposed. This would imply that a marine longshore current reworked the sand transported by palaeorivers and settled it northward along the coast of the young Atlantic Ocean (during the Albian). A parallel between Albian clastic deposits and the modern sediments deposited by the Benguela current is drawn, focusing on the striking resemblance between the two currents, i.e. the actual Benguela current and the Albian marine current, and the associated sedimentary bodies.
Search for Magnetic Monopoles with the MoEDAL Forward Trapping Detector in 13 TeV Proton-Proton Collisions at the LHC
2017
MoEDAL is designed to identify new physics in the form of long-lived highly-ionising particles produced in high-energy LHC collisions. Its arrays of plastic nuclear-track detectors and aluminium trapping volumes provide two independent passive detection techniques. We present here the results of a first search for magnetic monopole production in 13 TeV proton-proton collisions using the trapping technique, extending a previous publication with 8 TeV data during LHC run-1. A total of 222 kg of MoEDAL trapping detector samples was exposed in the forward region and analysed by searching for induced persistent currents after passage through a superconducting magnetometer. Magnetic charges excee…
Performance Study of Split Ferrite Cores Designed for EMI Suppression on Cables
2020
The ideal procedure to start designing an electronic device is to consider the electromagnetic compatibility (EMC) from the beginning. Even so, EMC problems can appear afterward, especially when the designed system is interconnected with external devices. Thereby, electromagnetic interferences (EMIs) could be transmitted to our device from power cables that interconnect it with an external power source or are connected to another system to establish wired communication. The application of an EMI suppressor such as a sleeve core that encircles the cables is a widely used technique to attenuate EM disturbances. This contribution is focused on the characterization of a variation of this cable …