Search results for "Cutaneous"
showing 10 items of 1022 documents
Percutaneous puncture of an aorto‐bifemoral bypass graft and successful closure with MANTA ® device in transfemoral TAVR
2021
Transfemoral aortic valve replacement (TAVR) has become a standard therapeutic option for patients with symptomatic severe aortic stenosis. Special anatomies can pose distinct challenges for vascular access and later closure of the access site, for example, in preoperated patients. Here, we elucidate a case of transfemoral TAVR with vascular access by direct puncture of an aorto-bifemoral bypass graft and illustrate the feasibility of vascular closure by an anchored collagen-plug vascular closure device (Teleflex MANTA® ).
Percutaneous trigger finger release with an MS64 scalpel
2019
Angioplastie der Arteria subclavia: Technik, Früh- und Spätergebnisse
2008
Percutaneous transluminal angioplasty (PTA) was performed in 22 patients (13 women and nine men; mean age 57 years [44-74] ) with symptomatic obstruction of the subclavian artery which was due to arteriosclerotic stenosis in 14, occlusion in six patients, radiogenic multiple stenoses in one (after radiotherapy for breast cancer), and stenoses of the left and right subclavian artery in one patient with Takayasu's arteritis. Primary success occurred in 21 (91%). The only complication was a stenosis of the brachial artery after combined brachiofemoral recanalization of a subclavian artery occlusion, but it did not require treatment. No emboli were noted. A good long-term result was achieved in…
Instrumentation and Surgical Technique
2013
Guideliner use for the percutaneous treatment of right coronary artery arising from the left circumflex (L-type single coronary artery)
2015
Perkutane Implantation einer endovaskulären Gianturco-Prothese bei V.-subclavia-Verschluß
1989
Observation d'une femme de 72 ans, hemodialysee, avec œdeme croissant du bras portant le shunt. L'obliteration de la veine sous-claviere a ete traitee par fibrinolyse locale, dilatation et prothese de Gianturco
Evaluating the quality of implantation of percutaneous ventricular restoration device (Parachute®) by cardiac computed tomography
2016
Background The Parachute is a novel percutaneously implanted ventricular partitioning device (VPD) that has emerged as a safe and feasible treatment option for patients with heart failure following anterior wall myocardial infarction. VPD efficacy is likely dependent on optimal device placement, but to date there are no published data examining the effect of device positioning on patient outcomes. Methods and results We retrospectively identified 32 patients successfully implanted with the Parachute device, all of whom underwent cardiac computed tomography (CCT) at baseline and after 6 months of follow-up. Patients were divided into two groups based on self-reported improvement in New York …
Die Diagnostik des hilären Cholangiokarzinoms: Wertigkeit von präoperativer ERC, MRC und PTC im Vergleich zur Histopathologie
2005
PURPOSE To compare the results of the preoperative workup consisting of endoscopic retrograde cholangiography (ERC), magnetic resonance cholangiography (MRC), and percutaneous resonance cholangiography (PTC) with the tumor extent of the surgical specimen in patients with hilar cholangiocarcinoma (hilCC). MATERIALS AND METHODS Between 9/1997 and 12/2002, 59 patients with hilCC tumor underwent surgical resection. Preoperative ERC, MRC, and PTC were analyzed, blinded for the identity of the patient, and compared with the surgical specimen. For this retrospective analysis, 55 of the initial 59 ERCs, 39 of the initial 40 MRCs and 32 of the initial 38 PTCs were available. Most of the ERCs and MRC…
Verschlußikterus: histologische Diagnostik durch perkutane endoluminale Gallengangsbiopsie
1991
32 forceps biopsies were performed in 30 patients with obstructive jaundice during percutaneous transhepatic biliary drainage procedures. In one patient an adequate specimen could not be obtained. In 25 of the remaining 31 cases diagnosis was confirmed histologically (malignant tumours: n = 22, benign stricture: n = 3). In 6 patients false-negative results were obtained. Transluminal biopsy is an easily performed adjunct to percutaneous transhepatic diagnostic interventions with minimal additional discomfort for the patient. In many cases percutaneous needle biopsy can be avoided. Forceps biopsy enables nonoperative histological diagnosis of small carcinomas of the bile ducts.
Die direkte perkutane radiologische Jejunostomie (PRJ) und Duodenostomie: eine retrospektive Auswertung
2005
Purpose: To present our experience with direct percutaneous radiologic duodenostomy and jejunostomy (PRJ) for alimentation. Materials and Methods: A retrospective study identified 24 patients who had undergone percutaneous jejunostomy or duodenostomy guided by CT and fluoroscopy over a period of 9 years. Whenever possible, the jejunum was inflated with a 5 French diagnostic catheter and jejunopexy was performed using Cope anchors (T-fasteners). A 12 to 14 French locking pigtail drain was inserted for alimentation. In 8 patients, percutaneous direct jejunostomy was performed using only fluoroscopy. In 9 patients, both CT and fluoroscopy were used to guide the jejunostomy. In all 7 patients w…