Search results for "Cyc"

showing 10 items of 11160 documents

The effect of plasma instabilities on the background impurities in charge breeder ECRIS

2017

International audience; Experimental observations of plasma instabilities in the 14.5 GHz PHOENIX charge breeder ECRIS are summarized. It has been found that the injection of 133Cs+ or 85Rb+ into oxygen discharge of the CB-ECRIS can trigger electron cyclotron instabilities, which results to sputtering of the surfaces exposed to the plasma, followed by up to an order of magnitude increase of impurity currents in the extracted n+ charge state distribution. The transition from stable to unstable plasma regime is caused by gradual accumulation and ionization of Cs/Rb altering the discharge parameters in 10 - 100 ms time scale, not by a prompt interaction between the incident ion beam and the EC…

010302 applied physicsMaterials scienceIon beamta114syklotronit[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Buffer gasCyclotronPlasmaElectroncharge breederplasmafysiikka7. Clean energy01 natural sciences010305 fluids & plasmaslaw.inventionIonECRISSputteringlawIonization0103 physical sciencesAtomic physicsplasma (kaasut)plasma
researchProduct

Quartz resonators for penning traps toward mass spectrometry on the heaviest ions

2020

We report on cyclotron frequency measurements on trapped 206,207Pb+ ions by means of the non-destructive Fourier-transform ion-cyclotron-resonance technique at room temperature. In a proof-of-principle experiment using a quartz crystal instead of a coil as a resonator, we have alternately carried out cyclotron frequency measurements for 206Pb+ and 207Pb+ with the sideband coupling method to obtain 21 cyclotron-frequency ratios with a statistical uncertainty of 6 × 10−7. The mean frequency ratio R¯ deviates by about 2σ from the value deduced from the masses reported in the latest Atomic Mass Evaluation. We anticipate that this shift is due to the ion–ion interaction between the simultaneousl…

010302 applied physicsMaterials scienceSidebandCyclotronMass spectrometry01 natural sciences7. Clean energyAtomic mass010305 fluids & plasmaslaw.inventionIonCrystalResonatorPhysics::Plasma Physicslaw0103 physical sciencesAtomic physicsddc:620InstrumentationQuartz
researchProduct

The role of seed electrons on the plasma breakdown and preglow of electron cyclotron resonance ion source

2009

The 14 GHz Electron Cyclotron Resonance Ion Source at University of Jyväskylä, Department of Physics (JYFL) has been operated in pulsed mode in order to study the plasma breakdown and preglow effect. It was observed that the plasma breakdown time and preglow characteristics are affected by seed electrons provided by a continuous low power microwave signal at secondary frequency. Sustaining low density plasma during the off-period of high power microwave pulses at the primary frequency shifts the charge state distribution of the preglow transient toward higher charge states. This could be exploited for applications requiring fast and efficient ionization of radioactive elements as proposed f…

010302 applied physicsMaterials science[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Cyclotron resonancechemistry.chemical_elementPlasmaElectron01 natural sciences7. Clean energyElectron cyclotron resonanceIon source010305 fluids & plasmasNeonchemistryIonizationBeta (plasma physics)0103 physical sciencesAtomic physicsInstrumentationComputingMilieux_MISCELLANEOUSReview of Scientific Instruments
researchProduct

The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source.

2016

The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the ca…

010302 applied physicsMaterials scienceta114Highly charged ionPlasma01 natural sciencesElectron cyclotron resonanceIon sourcemicrowaves010305 fluids & plasmasIonmikroaallotPhysics::Plasma Physics0103 physical scienceselectron cyclotron resonance ion sourcesplasma chamberAtomic physicsInstrumentationBeam (structure)MicrowaveMicrowave cavityThe Review of scientific instruments
researchProduct

Kinetic instabilities in pulsed operation mode of a 14 GHz electron cyclotron resonance ion source

2016

The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz Aelectron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10- 100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime. peerReviewed

010302 applied physicsMaterials scienceta114Ion beamCyclotron resonancePlasma01 natural sciencesplasma electronsIon sourceElectron cyclotron resonanceFourier transform ion cyclotron resonance010305 fluids & plasmasMagnetic fieldpulsed operation modePhysics::Plasma Physics0103 physical scienceselectron cyclotron resonance ion sourceskinetic instabilitiesAtomic physicsInstrumentationIon cyclotron resonanceReview of Scientific Instruments
researchProduct

Recent improvements of the LPSC charge breeder

2017

International audience; PSC has developed the PHOENIX electron cyclotron resonance Charge Breeder since 2000. The performances have been improved over time acting on the 1+ and N+ beam optics, the base vacuum and the 1+ beam injection. A new objective is to update the booster design to enhance high charge state production and 1+ N+ efficiencies, reduce the co-extracted background beam and improve the ion source tunability. The first step, consisting in increasing the peak magnetic field at injection from 1.2 T to 1.6 T was implemented and significant improvement in 1+N+ efficiencies are reported: 12.9% of 23Na8+, 24.2% of 40Ar8+, 13.3% of 132Xe26+ and 13% of 133Cs26+. The next steps of the …

010302 applied physicsMaterials scienceta114Nuclear engineering[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]syklotronitCharge (physics)plasmatekniikka01 natural sciences7. Clean energy010305 fluids & plasmaselectron cyclotron resonanceBreeder (animal)0103 physical sciencesplasma
researchProduct

Photoelectron Emission from Metal Surfaces Induced by Radiation Emitted by a 14 GHz Electron Cyclotron Resonance Ion Source

2015

Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma have a negligible contribution to the photoelectron emission. It is estimated from the measured data that the maximum conceivable photoelectron flux from plasma chamber walls is on the order of 10% of the estimated total electron losses from the plasma. peerReviewed

010302 applied physicsMaterials scienceta114Physics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaCyclotron resonanceBremsstrahlungFOS: Physical sciencesPlasmaElectronphotoelectron emissionRadiation01 natural sciences7. Clean energyElectron cyclotron resonanceIon sourcePhysics - Plasma Physics010305 fluids & plasmasPlasma Physics (physics.plasm-ph)Physics::Plasma Physics0103 physical scienceselectron cyclotron resonance ion sourcesPlasma diagnosticsAtomic physicsInstrumentation
researchProduct

Power efficiency improvements with the radio frequency H− ion source

2016

CW 13.56 MHz radio frequency-driven H(-) ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H(-) beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation …

010302 applied physicsMaterials scienceta114ta213Electromagnetbusiness.industryRF power amplifierCyclotronPlasma01 natural sciencesIon sourcelaw.inventionion sourceslawMagnet0103 physical sciencesOptoelectronicsRadio frequencypower efficiency010306 general physicsbusinessInstrumentationElectrical efficiencyReview of Scientific Instruments
researchProduct

New progress of high current gasdynamic ion source (invited).

2016

The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)—the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller’s ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 1013 cm−3 ) …

010302 applied physicsMaterials scienceta114ta213ion beamsPlasma01 natural sciencesIon sourceElectron cyclotron resonance010305 fluids & plasmaslaw.inventionIonlawGyrotronIonizationgasdynamic ECRIS0103 physical scienceselectron cyclotron resonance ion sourcesThermal emittanceAtomic physicsInstrumentationMicrowaveThe Review of scientific instruments
researchProduct

Charge breeding time investigations of electron cyclotron resonance charge breeders

2018

To qualify electron cyclotron resonance charge breeders, the method that is traditionally used to evaluate the charge breeding time consists in generating a rising edge of the injected beam current and measuring the time in which the extracted multicharged ion beam reaches 90% of its final current. It is demonstrated in the present paper that charge breeding times can be more accurately measured by injecting short pulses of 1 + ions and recording the time resolved responses of N + ions. This method is used to probe the effect of the 1 + ion accumulation in the plasma known to disturb the buffer gas plasma equilibrium and is a step further in understanding the large discrepancies reported in…

010302 applied physicsNuclear and High Energy PhysicsMaterials sciencePhysics and Astronomy (miscellaneous)ta114syklotronit[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]electronsCharge (physics)Surfaces and Interfacesresonanssielektronit7. Clean energy01 natural sciencesElectron cyclotron resonance010305 fluids & plasmasresonance0103 physical sciencescharge breederslcsh:QC770-798lcsh:Nuclear and particle physics. Atomic energy. RadioactivityAtomic physicscyclotronsReview Articles
researchProduct