Search results for "Cyclotron"
showing 10 items of 320 documents
A possible cyclotron resonance scattering feature near 0.7 keV in X1822-371
2015
We analyse all available X-ray observations of X1822-371 made with XMM-Newton, Chandra, Suzaku and INTEGRAL satellites. The observations were not simultaneous. The Suzaku and INTEGRAL broad band energy coverage allows us to constrain the spectral shape of the continuum emission well. We use the model already proposed for this source, consisting of a Comptonised component absorbed by interstellar matter and partially absorbed by local neutral matter, and we added a Gaussian feature in absorption at $\sim 0.7$ keV. This addition significantly improves the fit and flattens the residuals between 0.6 and 0.8 keV. We interpret the Gaussian feature in absorption as a cyclotron resonant scattering …
A 0535+26 in the August/September 2005 outburst observed by RXTE and INTEGRAL
2007
In this Letter we present results from INTEGRAL and RXTE observations of the spectral and timing behavior of the High Mass X-ray Binary A 0535+26 during its August/September 2005 normal (type I) outburst with an average flux F(5-100keV)~400mCrab. The search for cyclotron resonance scattering features (fundamental and harmonic) is one major focus of the paper. Our analysis is based on data from INTEGRAL and RXTE Target of Opportunity Observations performed during the outburst. The pulse period is determined. X-ray pulse profiles in different energy ranges are analyzed. The broad band INTEGRAL and RXTE pulse phase averaged X-ray spectra are studied. The evolution of the fundamental cyclotron …
Observation of Poincaré-Andronov-Hopf Bifurcation in Cyclotron Maser Emission from a Magnetic Plasma Trap.
2018
We report the first experimental evidence of a controlled transition from the generation of periodic bursts of electromagnetic radiation into the continuous-wave regime of a cyclotron maser formed in magnetically confined nonequilibrium plasma. The kinetic cyclotron instability of the extraordinary wave of weakly inhomogeneous magnetized plasma is driven by the anisotropic electron population resulting from electron cyclotron plasma heating in a MHD-stable minimum-$B$ open magnetic trap.
The complex formation of tetracyclohexylammonium C1-resorcinarene with various guests - an electrospray ionization Fourier transform ion cyclotron re…
2008
The complex formation of a tetraammonium C1-resorcinarene (R+4HCl) was studied using electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry. Although R+4HCl easily loses its counter ions in the ESI process, a neutral self-assembled structure with an intramolecular circular hydrogen-bonded 16-membered -N(+)-H ... X(-) ... H-N(+)- array with ammonium ion as the charge-giving species was observed in the gas phase. In addition to chloride, several other counter ions were also studied. The size and basicity of the counter ion as well as the size of the charge-giving cation strongly affected the gas-phase stability of the self-assembled system. H/D exchang…
Internal ion impact ionization for Fourier-transform ion cyclotron resonance
1994
A general scheme for ionization and fragmentation of ions in Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICRMS) is introduced. The technique is based upon excitation of high-frequency (i.e. lowmass) primary ions (e.g. N, Al+, H2O+·) which may be generated by standard ionization methods (e.g. electron ionization or laser desorption) inside the trap. Generation of the primary ions is followed by excitation of their cyclotron motion to high translational energy to serve as projectile ions. The projectiles serve two functions: to ionize neutral gas atoms and/or molecules (secondary ions) within the trap internal ion impact ionization (IIII), and to collisionally activate the…
Making Broad Proteome Protein Measurements in 1−5 min Using High-Speed RPLC Separations and High-Accuracy Mass Measurements
2005
The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both…
Studies of electron heating on a 6.4 GHz ECR ion source through measurement of diamagnetic current and plasma bremsstrahlung
2011
Diamagnetic current and low energy (2–70 keV) x-ray bremsstrahlung measurements taken on a 6.4 GHz electron cyclotron resonance ion source (ECRIS) are presented as a function of microwave power, neutral gas pressure and magnetic field configuration. X-ray flux from confined electrons and plasma energy density depend logarithmically on microwave power. This result differs from previous studies performed on ECRISs that operate at higher microwave frequencies, in which the x-ray power increases in an essentially linear fashion with the microwave power. X-ray power and plasma energy density both saturate as the neutral pressure is increased beyond a certain value. The gradient of the magnetic f…
The Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results
2007
The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external radiofrequency-quadrupole fields. In this work a new excitation scheme, Ramsey's method of time-separated oscillatory fields, has been successfully tested. It has been shown to reduce significantly the uncertainty in the determination of the cyclotron frequency and thus of the ion mass of interest. The theoretical description of the ion motion excited with Ramsey's method in a Penning trap and subsequently the calculation of the resonance line shapes for differ…
Theory of simultaneous dipole and quadrupole excitation of the ion motion in a Penning trap
2012
Abstract Penning traps confine ions of atoms and molecules as well as other charged particles by a combination of static electric and magnetic fields to the central region of the trap, where these objects can be studied. Most experiments employ pulses of dipolar radio-frequency radiation followed by pulses of quadrupolar radio-frequency radiation to manipulate the motional state of the trapped particles. Instead of a sequential procedure an excitation of the ion motion by the simultaneous application of dipolar and quadrupolar rf-fields is also conceivable. This paper investigates the theory of simultaneous excitation under very general assumptions, with inclusion of possible damping terms.…
Quadrupole excitation of stored ion motion at the true cyclotron frequency
1995
Abstract The motion of an ion in a Penning trap has been investigated in the presence of an azimuthal quadrupole radio frequency field and a damping force provided by buffer gas collisions. Analytical expressions are derived which describe the line shape of the cyclotron resonance as well as the properties of the mass-selective cooling mechanism for heavy ions. Excellent agreement is observed between theoretical results and experimental data obtained with the tandem Penning trap mass spectromer ISOLTRAP at ISOLDE (CERN).