Search results for "Cyclotrons"

showing 10 items of 14 documents

Charge breeding time investigations of electron cyclotron resonance charge breeders

2018

To qualify electron cyclotron resonance charge breeders, the method that is traditionally used to evaluate the charge breeding time consists in generating a rising edge of the injected beam current and measuring the time in which the extracted multicharged ion beam reaches 90% of its final current. It is demonstrated in the present paper that charge breeding times can be more accurately measured by injecting short pulses of 1 + ions and recording the time resolved responses of N + ions. This method is used to probe the effect of the 1 + ion accumulation in the plasma known to disturb the buffer gas plasma equilibrium and is a step further in understanding the large discrepancies reported in…

010302 applied physicsNuclear and High Energy PhysicsMaterials sciencePhysics and Astronomy (miscellaneous)ta114syklotronit[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]electronsCharge (physics)Surfaces and Interfacesresonanssielektronit7. Clean energy01 natural sciencesElectron cyclotron resonance010305 fluids & plasmasresonance0103 physical sciencescharge breederslcsh:QC770-798lcsh:Nuclear and particle physics. Atomic energy. RadioactivityAtomic physicscyclotronsReview Articles
researchProduct

Molecular similarities and differences from human pulmonary fibrosis and corresponding mouse model: MALDI imaging mass spectrometry in comparative me…

2017

Animal models can reproduce some model-specific aspects of human diseases, but some animal models translate poorly or fail to translate to the corresponding human disease. Here, we develop a strategy to systematically compare human and mouse tissues, and conduct a proof-of-concept experiment to identify molecular similarities and differences using patients with idiopathic pulmonary fibrosis and a bleomycin-induced fibrosis mouse model. Our novel approach employs high-throughput tissue microarrays (TMAs) of humans and mice, high-resolution matrix-assisted laser desorption/ionization-Fourier transform-ion cyclotron resonance-mass spectrometry imaging (MALDI-FT-ICR-MSI) to spatially resolve ma…

0301 basic medicineMALDI imagingPulmonary FibrosisSecondary MetabolismComputational biologyBiologyBioinformaticsProof of Concept StudyPathology and Forensic MedicineBleomycinMice03 medical and health sciencesIdiopathic pulmonary fibrosisMetabolomicsSpecies SpecificityFibrosisAdministration InhalationSpectroscopy Fourier Transform InfraredPulmonary fibrosismedicineAnimalsCluster AnalysisHumansMetabolomicsLungPhysiology ComparativeMolecular BiologyAntibiotics AntineoplasticTissue microarrayCell BiologyCyclotronsmedicine.diseaseImmunohistochemistryDisease Models AnimalMatrix-assisted laser desorption/ionization030104 developmental biologyTissue Array AnalysisSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationImmunohistochemistryLaboratory Investigation
researchProduct

Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…

2019

Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…

AnalyteEnvironmental EngineeringMaterials scienceFood SafetyHalogenationHealth Toxicology and Mutagenesis0208 environmental biotechnologyAtmospheric-pressure chemical ionization02 engineering and technology010501 environmental sciences01 natural sciencesFourier transform ion cyclotron resonanceGas Chromatography-Mass SpectrometryMass SpectrometryCalibrationHalogenated Diphenyl EthersEnvironmental ChemistryHumans0105 earth and related environmental sciencesFlame RetardantsDetection limitChromatographyFourier AnalysisPublic Health Environmental and Occupational HealthGeneral MedicineGeneral ChemistryRepeatabilityCyclotronsPollution020801 environmental engineeringFoodFood productsGas chromatographyFood AnalysisChemosphere
researchProduct

Observation of Poincaré-Andronov-Hopf Bifurcation in Cyclotron Maser Emission from a Magnetic Plasma Trap.

2018

We report the first experimental evidence of a controlled transition from the generation of periodic bursts of electromagnetic radiation into the continuous-wave regime of a cyclotron maser formed in magnetically confined nonequilibrium plasma. The kinetic cyclotron instability of the extraordinary wave of weakly inhomogeneous magnetized plasma is driven by the anisotropic electron population resulting from electron cyclotron plasma heating in a MHD-stable minimum-$B$ open magnetic trap.

Astrophysics::High Energy Astrophysical PhenomenaCyclotronGeneral Physics and AstronomyElectronplasmafysiikka01 natural sciences7. Clean energyInstabilityElectromagnetic radiation010305 fluids & plasmaslaw.inventionsymbols.namesakePhysics::Plasma PhysicslawMagnetic trap0103 physical sciencesMaser010306 general physicsPhysicsHopf bifurcationta114plasma physicssyklotronitPlasmaPhysics::Space PhysicssymbolsAtomic physicscyclotronsPhysical review letters
researchProduct

The complex formation of tetracyclohexylammonium C1-resorcinarene with various guests - an electrospray ionization Fourier transform ion cyclotron re…

2008

The complex formation of a tetraammonium C1-resorcinarene (R+4HCl) was studied using electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry. Although R+4HCl easily loses its counter ions in the ESI process, a neutral self-assembled structure with an intramolecular circular hydrogen-bonded 16-membered -N(+)-H ... X(-) ... H-N(+)- array with ammonium ion as the charge-giving species was observed in the gas phase. In addition to chloride, several other counter ions were also studied. The size and basicity of the counter ion as well as the size of the charge-giving cation strongly affected the gas-phase stability of the self-assembled system. H/D exchang…

Bridged-Ring CompoundsModels MolecularBenzylaminesSpectrometry Mass Electrospray IonizationElectrospray ionizationPhenylalanineAnalytical chemistryMass spectrometryFourier transform ion cyclotron resonanceAnalytical ChemistryIonchemistry.chemical_compoundSpectroscopy Fourier Transform InfraredAmmoniumDicarboxylic AcidsSpectroscopychemistry.chemical_classificationOrganic ChemistryResorcinareneCyclotronschemistryIntramolecular forceData Interpretation StatisticalSolventsIndicators and ReagentsCounterionCalixarenesRapid communications in mass spectrometry : RCM
researchProduct

Observation of Poincaré-Andronov-Hopf Bifurcation in Cyclotron Maser Emission from a Magnetic Plasma Trap

2018

We report the first experimental evidence of a controlled transition from the generation of periodic bursts of electromagnetic radiation into the continuous-wave regime of a cyclotron maser formed in magnetically confined nonequilibrium plasma. The kinetic cyclotron instability of the extraordinary wave of weakly inhomogeneous magnetized plasma is driven by the anisotropic electron population resulting from electron cyclotron plasma heating in a MHD-stable minimum-B open magnetic trap. peerReviewed

Electromagnetic wavesAstrophysics::High Energy Astrophysical PhenomenasyklotronitPlasma stabilitysähkömagnetismiCyclotronsplasmafysiikkamaseritPlasma diagnosticsMagnetohydrodynamicsPhysics::Plasma PhysicsPhysics::Space PhysicsMasersHopf bifurcationMagnetoplasma
researchProduct

The electron cyclotron resonance ion source with arc-shaped coils concept

2012

The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cos…

Materials scienceIon beamOptical PhenomenaPlasma Gasesta114Highly charged ionCyclotron resonanceTemperatureParticle acceleratorElectronsCyclotronsModels TheoreticalIon gunIon sourceElectron cyclotron resonancelaw.inventionMagnetic FieldslawAtomic physicsInstrumentationIon cyclotron resonanceReview of Scientific Instruments
researchProduct

Innovative remotely-controlled bending device for thin silicon and germanium crystals

2020

Steering of negatively charged particle beams below 1 GeV has demonstrated to be possible with thin bent silicon and germanium crystals. A newly designed mechanical holder was used for bending crystals, since it allows a remotely-controlled adjustment of crystal bending and compensation of unwanted torsion. Bent crystals were installed and tested at the MAMI Mainz MIcrotron to achieve steering of 0.855-GeV electrons at different bending radii. We report the description and characterization of the innovative bending device developed at INFN Laboratori Nazionali di Legnaro (LNL).

Physics - Instrumentation and DetectorsMaterials scienceAccelerator ApplicationsSiliconBeam OpticsNegatively charged particleAccelerator Applications; Beam Optics; Instrumentation for particle accelerators and storage rings - high energy (linear accelerators synchrotrons); Instrumentation for particle accelerators and storage rings - lowenergy (linear accelerators cyclotrons electrostatic accelerators); Instrumentation; Mathematical PhysicsBent molecular geometryFOS: Physical scienceschemistry.chemical_elementGermaniumElectron01 natural sciencesInstrumentation for particle accelerators and storage rings - lowenergy (linear accelerators cyclotrons electrostatic accelerators)Instrumentation for particle accelerators and storage rings - high energy (linear accelerators synchrotrons)NOCrystal0103 physical sciencesNuclear Experiment010306 general physicsInstrumentationMicrotronMathematical Physics010308 nuclear & particles physicsbusiness.industryTorsion (mechanics)Instrumentation and Detectors (physics.ins-det)chemistryPhysics::Accelerator PhysicsOptoelectronicsbusinessJournal of Instrumentation
researchProduct

Transverse distribution of beam current oscillations of a 14 GHz electron cyclotron resonance ion source

2014

The temporal stability of oxygen ion beams has been studied with the 14 GHz A-ECR at JYFL (University of Jyvaskyla, Department of Physics). A sector Faraday cup was employed to measure the distribution of the beam current oscillations across the beam profile. The spatial and temporal characteristics of two different oscillation “modes” often observed with the JYFL 14 GHz ECRIS are discussed. It was observed that the low frequency oscillations below 200 Hz are distributed almost uniformly. In the high frequency oscillation “mode,” with frequencies >300 Hz at the core of the beam, carrying most of the current, oscillates with smaller amplitude than the peripheral parts of the beam. The result…

Physicsta114Oscillationbeam current oscillationsCyclotronElectric Conductivitytransverse distributionFaraday cupElectronsCyclotronsLower hybrid oscillationPlasma oscillationElectron cyclotron resonancelaw.inventionsymbols.namesakelawUpper hybrid oscillationsymbolsAtomic physicsInstrumentationBeam (structure)Review of Scientific Instruments
researchProduct

An electrospray ionization Fourier transform ion cyclotron resonance mass spectrometric study of the gas-phase stabilities and fragmentation ofN-alky…

2006

Five N-alkylated ammonium resorcarene derivatives, differing either in the nitrogen atom or in the lower rim alkyl chain, were studied using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. The main purpose was to clarify the fragmentation and the relative stabilities of the protonated molecules by collision-induced dissociation (CID) experiments. The results indicate that fragmentation of the upper rim alkyl amino substituents at the 2-position occurs readily. Variation in the gas-phase stabilities of these molecules was also observed. In addition, the proposed fragmentation pathways are depicted.

Spectrometry Mass Electrospray IonizationChemical ionizationAlkylationCollision-induced dissociationChemistryElectrospray ionizationOrganic ChemistryAnalytical chemistryResorcinolsCyclotronsMass spectrometryPhase TransitionIon sourceFourier transform ion cyclotron resonanceAnalytical ChemistryQuaternary Ammonium CompoundsFragmentation (mass spectrometry)OxazinesSpectroscopy Fourier Transform InfraredGasesSpectroscopyIon cyclotron resonanceRapid Communications in Mass Spectrometry
researchProduct