Search results for "Cyfluthrin"

showing 3 items of 3 documents

Determination of pyrethroid insecticide residues in vegetable oils by using combined solid-phases extraction and tandem mass spectrometry detection

2005

Abstract A methodology has been developed for the determination of pyrethroid insecticide residues in vegetable oils, based in a solid-phase extraction (SPE) with combined solid supports phases. Several solid phases such as florisil, alumina, C18 and graphitized carbon black were tested in order to minimize fat residues, being a combination of treated alumina and C18 which provided the best results. Oil samples were partitioned with acetonitrile–hexane (1:1) and then eluted through a combined column packed with deactivated basic-alumina and C18, employing the acetonitrile extract as elution solvent. Gas chromatography tandem mass spectrometry was used for determination. Tetramethrin, Bifent…

ChromatographyGas Chromatography/Tandem Mass SpectrometryBifenthrinCyfluthrinBiochemistryAnalytical Chemistrychemistry.chemical_compoundVegetable oilchemistryFlucythrinateEnvironmental ChemistrySolid phase extractionPhenothrinTetramethrinSpectroscopyAnalytica Chimica Acta
researchProduct

Microwave-assisted extraction of pyrethroid insecticides from soil

2004

Abstract An analytical method has been developed for the microwave-assisted extraction of synthetic pyrethroid insecticide residues in soils and their determination by gas chromatography with electron capture detector (ECD) and mass spectrometry (MS) detector. Clean soil samples were spiked with nine pyrethroids: tetramethrin, cyfluthrin, flucythrinate, deltamethrin, bifenthrin, permethrin, cypermethrin and fluvalinate were used for this study. Concentration levels were 50 ng g −1 for all the compounds studied except to sumitrin for which a 10 μg g −1 was evaluated. Two grams of sample were treated in a closed PTFE reactor with 10 mL toluene and 1 mL water and irradiated at 700 W during 9 m…

PyrethroidChromatographyChemistryBifenthrinExtraction (chemistry)CyfluthrinBiochemistryAnalytical ChemistryFluvalinatechemistry.chemical_compoundElectron capture detectorFlucythrinateEnvironmental ChemistryTetramethrinSpectroscopyAnalytica Chimica Acta
researchProduct

Microwave-assisted extraction of pyrethroid insecticides from semi permeable membrane devices (SPMDs) used to indoor air monitoring

2006

Abstract A rapid and environmentally friendly methodology was developed for the extraction of pyrethroid insecticides from semi permeable membrane devices (SPMDs), in which they were preconcentrated in gas phase. The method was based on gas chromatography mass–mass spectrometry determination after a microwave-assisted extraction, in front of the widely employed dialysis method. SPMDs were extracted twice with 30 mL hexane:acetone, irradiated with 250 W power output, until 90 °C in 10 min, this temperature being held for another 10 min. Clean-up of the extracts was performed by acetonitrile–hexane partitioning and solid-phase extraction (SPE) with a combined cartridge of 2 g basic-alumina, d…

PyrethroidChromatographyCyfluthrinPrallethrinBiochemistryAnalytical ChemistryFluvalinatechemistry.chemical_compoundchemistryEnvironmental chemistryFlucythrinateEnvironmental ChemistrySolid phase extractionPhenothrinTetramethrinSpectroscopyAnalytica Chimica Acta
researchProduct