Search results for "DAMPE"

showing 7 items of 127 documents

Intermediate Isolation System for the seismic retrofit of existing masonry buildings

2022

This paper deals with the potentials of Intermediate Isolation Systems (IIS) for retrofitting masonry buildings by means of a vertical extension, isolated at its base, and realized on the rooftop of the existing structure. By carefully defining the dynamic properties of the superstructure and isolation system, in previous papers the authors have demonstrated that this passive technique is able to reduce a priori the seismic demand on the existing building. For this reason, the non-linear behavior has been only assumed for the isolation system, with the masonry structure in the elastic field. This result has been validated by carrying out spectrum-compatible time history analyses on the 3D F…

masonry buildingsInter-story isolation systemseismic isolationnon-conventional tuned mass damperseismic retrofit
researchProduct

Random vibration mitigation of beams via tuned mass dampers with spring inertia effects

2019

The dynamics of beams equipped with tuned mass dampers is of considerable interest in engineering applications. Here, the purpose is to introduce a comprehensive framework to address the stochastic response of the system under stationary and non-stationary loads, considering inertia effects along the spring of every tuned mass damper applied to the beam. For this, the key step is to show that a tuned mass damper with spring inertia effects can be reverted to an equivalent external support, whose reaction force on the beam depends only on the deflection of the attachment point. On this basis, a generalized function approach provides closed analytical expressions for frequency and impulse res…

media_common.quotation_subjectSpring inertia effectStochastic response02 engineering and technologyInertia01 natural sciences0203 mechanical engineeringDeflection (engineering)Control theoryTuned mass damper0103 physical sciences010301 acousticsImpulse responsemedia_commonPhysicsGeneralized functionMechanical EngineeringBeamGeneralized functionCondensed Matter PhysicsTuned mass damper020303 mechanical engineering & transportsReactionMechanics of MaterialsRandom vibrationBeam (structure)
researchProduct

Numerical validation of an approximate formulation for the design of TLCD

2013

passive control tuned liquid column damper statistical linearization pre-design
researchProduct

Design Of TLCD under random loads: a new formulation

2012

passive control tuned liquid column damper stochastic linearizationSettore ICAR/08 - Scienza Delle Costruzioni
researchProduct

The Control Performance of TLCD and TMD: Experimental Investigation

2012

tuned liquid column damperpassive control
researchProduct

Passive Control of Linear Structures Equipped with non-Linear Viscous Dampers and Amplification Mechanism

2008

Fluid damper devices in civil structures such as buildings or bridges are commonly used as energy absorbers for seismic protection. The problem in the response analysis of structures with filled dampers mainly consists in the fact that, due to the strongly nonlinear behavior of such equipments, the response spectrum technique fails. Moreover, in order to enhance the damping effect various toggle brace configurations have been recently proposed. In this paper by using the concept of power spectral density function compatible with the elastic response spectrum and the stochastic linearization technique, the equivalent damping ratio is obtained. It is shown that once the system is linearized r…

viscous dampers nonlinearity seismic protection toggle brace power spectral density stochastic analysisSettore ICAR/08 - Scienza Delle Costruzioni
researchProduct

Stochastic seismic analysis of MDOF structures with viscous damper devices

2009

Fluid damper devices in civil structures such as buildings or bridges are commonly used as energy absorbers for seismic protection. The problem in the response analysis of structures with filled dampers mainly consists in the fact that, due to the strongly nonlinear behavior of such equipments, the response spectrum technique fails. In this paper by using the concept of power spectral density function compatible with the elastic response spectrum and the stochastic linearization technique, the equivalent damping ratio is obtained. It is shown that once the system is linearized results obtained by Monte Carlo simulation and those obtained by stochastic analysis are in good agreement. Respons…

viscous dampers stochastic linearization equivalent damping ratio non classically damped systemsSettore ICAR/08 - Scienza Delle Costruzioni
researchProduct