Helmet continuous positive airway pressure and prone positioning: A proposal for an early management of COVID-19 patients

2020

In late December 2019, clusters of patients with interstitial pneumonia of unknown cause were reported by some local health facilities in Wuhan (China). The Chinese Centre for Disease Control conducted an epidemiologic and etiologic investigation, leading to the identification of a novel coronavirus (SARS-CoV-2).1, 2 On March 11th, the World Health Organization (WHO) declared the novel coronavirus disease (COVID-19) a pandemic. In the area of Wuhan, COVID-19 mainly affected male patients (around 60%), with a median age of about 50 years; 40% of patients developed Acute Respiratory Distress Syndrome (ARDS) 5% requiring intensive care. The mortality rate was around 2%.3, 4 However, Grasselli …

Pulmonary and Respiratory Medicine2019-20 coronavirus outbreakmedicine.medical_specialtyCoronavirus disease 2019 (COVID-19)medicine.medical_treatmentSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)Pneumonia ViralcoronavirusArticlePatient PositioningPositive-Pressure RespirationBetacoronavirusPandemicmedicineHumansContinuous positive airway pressurePositive-Pressure RespirationHypoxiaLung CompliancePandemicslcsh:RC705-779Respiratory Distress SyndromeContinuous Positive Airway PressurebiologySARS-CoV-2business.industryhelmetCOVID-19lcsh:Diseases of the respiratory systembiology.organism_classificationProne positionVasoconstrictionprone positionEmergency medicineHead Protective DevicesCoronavirus InfectionsRespiratory InsufficiencybusinessBetacoronavirusCPCP COVID-19 SARS-CoV-2
researchProduct

Tidal volume and helmet: Is the never ending story coming to an end?

2021

Noninvasive ventilation (NIV) has been increasingly used in acute care setting with various indications, but its use in patients with acute hypoxemic respiratory failure (AHRF) is controversial. In this setting, reliable monitoring of Vt and unintentional leaks is of the utmost importance. The aim of this article is to describe the importance of tidal volume measurement in the context of AHRF treated with NIV.

Pulmonary and Respiratory Medicinelcsh:RC705-7792019-20 coronavirus outbreakmedicine.medical_specialtyCoronavirus disease 2019 (COVID-19)business.industrySevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)lcsh:Diseases of the respiratory systemEmergency medicinemedicineTidal VolumeHumansNoninvasive ventilationHead Protective DevicesbusinessNoninvasive ventilationTidal volumePulmonology
researchProduct

Use of Helmet CPAP in COVID-19 – A practical review

2021

Helmet CPAP (H-CPAP) has been recommended in many guidelines as a noninvasive respiratory support during COVID-19 pandemic in many countries around the world. It has the least amount of particle dispersion and air contamination among all noninvasive devices and may mitigate the ICU bed shortage during a COVID surge as well as a decreased need for intubation/mechanical ventilation. It can be attached to many oxygen delivery sources. The MaxVenturi setup is preferred as it allows for natural humidification, low noise burden, and easy transition to HFNC during breaks and it is the recommended transport set-up. The patients can safely be proned with the helmet. It can also be used to wean the p…

Pulmonary and Respiratory Medicinemedicine.medical_specialtyARDSCoronavirus disease 2019 (COVID-19)medicine.medical_treatmentEconomic shortageReviewRespiratory failureAir contamination03 medical and health sciencesDiseases of the respiratory system0302 clinical medicineMedicineIntubationHumans030212 general & internal medicineIntensive care medicineMechanical ventilationHelmetNoninvasive VentilationRC705-779Continuous Positive Airway Pressurebusiness.industrySARS-CoV-2Oxygen Inhalation TherapyCOVID-19medicine.diseaseLow noise030228 respiratory systemRespiratory failureHead Protective DevicesARDSNon-invasive mechanical ventilationbusinessRespiratory InsufficiencyVentilator WeaningPulmonology
researchProduct

Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study

2015

BACKGROUND: In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive respiratory conditions. METHODS: A test lung, connected to a pediatric mannequin using different interfaces (endotracheal tube [ETT], face mask, and helmet), was ventilated in pressure support ventilation mode testing 2 ventilator settings (pressurization time [Timepress]50%/cycling-off flow threshold [T…

Pulmonary and Respiratory Medicinemedicine.medical_specialtyRespiratory rateface maskPositive pressurePressure support ventilationRespiratory physiologyCritical Care and Intensive Care MedicineManikinsManikinPositive-Pressure Respirationendotracheal tubepatient-ventilator interactionSettore MED/41 - ANESTESIOLOGIAmedicineIntubation IntratrachealHumansIntensive care medicineChildInteractive Ventilatory Supportpressure-support ventilationLungVentilators MechanicalMaskRespiratory MechanicHead Protective Devicebusiness.industryRespirationMaskshelmetnoninvasive ventilationGeneral Medicinemedicine.anatomical_structureAnesthesiaBreathingRespiratory MechanicsHead Protective DevicesAirwaybusinessInteractive Ventilatory SupportHuman
researchProduct

The effect of tiotropium/olodaterol versus fluticasone propionate/salmeterol on left ventricular filling and lung hyperinflation in patients with COPD

2020

This exploratory, randomised, double-blind, double-dummy, multicentre, cross-over study explored the effect of 6 weeks of treatment with tiotropium/olodaterol (T/O) versus fluticasone propionate/salmeterol (F/S) on left ventricular filling in patients with chronic obstructive pulmonary disease with functional residual capacity (FRC) >120% predicted and postbronchodilator improvement of FRC ≥7.5%. Overall, 76 patients were randomised across nine sites. Treatment with T/O or F/S increased left ventricular end-diastolic volume index from baseline (adjusted mean change: T/O: 2.317 mL/m2, F/S: 2.855 mL/m2), with no statistically significant difference between treatments. However, T/O resulted…

Pulmonary and Respiratory Medicinemedicine.medical_specialtylcsh:MedicineFluticasone propionatePulmonary Disease Chronic Obstructive03 medical and health scienceschemistry.chemical_compound0302 clinical medicineFunctional residual capacityInternal medicinemedicineHumansMulticenter Studies as TopicPlethysmographIn patient1506030212 general & internal medicineTiotropium BromideLunginhaler devicesRandomized Controlled Trials as Topiclcsh:RC705-779COPDCross-Over Studiesbusiness.industrylcsh:ROlodaterollcsh:Diseases of the respiratory systemrespiratory systemmedicine.diseaseFluticasone-Salmeterol Drug CombinationBenzoxazinesBronchodilator Agentsrespiratory tract diseasesrespiratory measurement030228 respiratory systemchemistryPerspectiveCardiologyCOPD pharmacologySalmeterolVentricular fillingbusinessmedicine.drugBMJ Open Respiratory Research
researchProduct

The Poisson embedding approach to the Calderón problem

2020

We introduce a new approach to the anisotropic Calder\'on problem, based on a map called Poisson embedding that identifies the points of a Riemannian manifold with distributions on its boundary. We give a new uniqueness result for a large class of Calder\'on type inverse problems for quasilinear equations in the real analytic case. The approach also leads to a new proof of the result by Lassas and Uhlmann (2001) solving the Calder\'on problem on real analytic Riemannian manifolds. The proof uses the Poisson embedding to determine the harmonic functions in the manifold up to a harmonic morphism. The method also involves various Runge approximation results for linear elliptic equations.

Pure mathematicsRIEMANNIAN-MANIFOLDSDEVICESGeneral MathematicsBoundary (topology)INVISIBILITYPoisson distribution01 natural sciencesinversio-ongelmatsymbols.namesakeMathematics - Analysis of PDEs0103 physical sciences111 MathematicsREGULARITYUniqueness0101 mathematicsEQUATIONSMathematicsosittaisdifferentiaaliyhtälötCalderón problemCLOAKING010102 general mathematicsRiemannian manifoldInverse problemFULLManifoldPoisson embeddingHarmonic functionsymbolsEmbedding010307 mathematical physics35R30 (Primary) 35J25 53C21(Secondary)INVERSE PROBLEMSMathematische Annalen
researchProduct

Lipid-containing semipermeable membrane devices (SPMDs) as concentrators of toxic chemicals in the lower Fraser River, Vancouver, British Columbia.

1998

Abstract Semipermeable membrane devices (SPMDs) were deployed in the water column and in the sediments of the Lower Fraser River (B.C., Canada) to compare the levels and the congener profiles of polychlorinated dibenzo- p -dioxins (PCDDs), dibenzofurans (PCDFs) and non- ortho -chlorinated biphenyls (N-o,o′-PCBs) against those sampled by an Infiltrex resin column water sampler. Also the relationship between what was present in the ecosystem as sampled by SPMDs and what was accumulated in the tissue of resident benthic-feeding fish was explored. Only the lipid portion of the SPMDs was prepared for analysis, due to some technical difficulties in cleaning the polyethene tubing. The calculated w…

Quality ControlEnvironmental EngineeringHealth Toxicology and MutagenesisGas Chromatography-Mass Spectrometrychemistry.chemical_compoundWater columnEnvironmental ChemistryAnimalsSemipermeable membraneWater pollutionBenzofuransBritish ColumbiaChemistryPublic Health Environmental and Occupational HealthFishesMembranes ArtificialGeneral MedicineGeneral ChemistryMultiple sourcePollutionLipidsPolychlorinated BiphenylsChlorinated BiphenylsPentachlorophenolCongenerSemipermeable membrane devicesEnvironmental chemistryWater Pollutants ChemicalChemosphere
researchProduct

Narrative Medicine to integrate patients’, caregivers’ and clinicians’ migraine experiences: the DRONE multicentre project

2021

Abstract Background Although migraine is widespread and disabling, stigmatisation and poor awareness of the condition still represent barriers to effective care; furthermore, research on migraine individual and social impact must be enhanced to unveil neglected issues, such as caregiving burden. The project investigated the migraine illness experience through Narrative Medicine (NM) to understand daily life, needs and personal resources of migraneurs, their caregivers and clinicians, and to provide insights for clinical practice. Methods The project involved 13 Italian headache centres and targeted migraneurs, their caregivers and migraine specialists at these centres. Written narratives, c…

Quality of lifemedicine.medical_specialtyUnmanned Aerial DevicesMigraine Disordersmedia_common.quotation_subjectIllness experienceCoding (therapy)Illness experienceDermatologyQuality of life (healthcare)PerceptionmedicineHumansNarrativePsychiatryeducationMigrainemedia_commonNarrative medicineeducation.field_of_studyGeneral Medicinemedicine.diseaseDoctor-patient relationshipNarrative medicinePsychiatry and Mental healthCaregiversMigraineDoctor–patient relationshipOriginal ArticleNeurology (clinical)Psychology
researchProduct

The class of languages recognizable by 1-way quantum finite automata is not closed under union

2000

In this paper we develop little further the theory of quantum finite automata (QFA). There are already few properties of QFA known, that deterministic and probabilistic finite automata do not have e.g. they cannot recognize all regular languages. In this paper we show, that class of languages recognizable by QFA is not closed under union, even not under any Boolean operation, where both arguments are significant.

Quantum PhysicsTheoryofComputation_COMPUTATIONBYABSTRACTDEVICESFOS: Physical sciencesComputer Science::Computational ComplexityQuantum Physics (quant-ph)Computer Science::Formal Languages and Automata Theory
researchProduct

Effects of Scientific Information Format on the Comprehension Self-Monitoring Processes: Question Generation

2013

RESUMEN: Formular preguntas es una de las acciones asociadas con procesos metacognitivos de regulación durante tareas de comprensión: los sujetos pueden generar preguntas destinadas a obtener información para salvar obstáculos de comprensión. Se realizaron dos experimentos para estimular, clasificar y analizar las preguntas de los estudiantes en tres condiciones diferentes: leer sobre el funcionamiento de dispositivos científicos experimentales, observarlos en un DVD o manipularlos en el Laboratorio. Las preguntas fueron clasificadas usando una taxonomía sencilla. Teniendo en cuenta los principios multimedia de aprendizaje, las ventajas de imágenes realistas animadas para el aprendizaje de …

Question generationDispositivos experimentalesExperimental devicesAutorregulaciónGeneración de preguntasSelf-regulationDidáctica de las ciencias experimentalesCiències de l'educacióScience education