Search results for "DEVICES"
showing 10 items of 615 documents
Wearable Sensor for Assessing Gait and Postural Alterations in Patients with Diabetes: A Scoping Review.
2021
Background and Objectives: Diabetes mellitus is considered a serious public health problem due to its high prevalence and related complications, including gait and posture impairments due to neuropathy and vascular alterations and the subsequent increased risk of falls. The gait of patients with diabetes is characterized by alterations of the main spatiotemporal gait parameters such as gait velocity, cadence, stride time and length, which are also known to worsen with disease course. Wearable sensor systems can be used for gait analysis by providing spatiotemporal parameters and postural control (evaluated from the perspective of body sway), useful for investigating the disease progression.…
Focus on right ventricular outflow tract septal pacing
2013
SummaryExperimental and clinical studies have shown that right ventricular apical pacing may result in long-term deleterious effects on account of its negative impact on left ventricular remodeling through desynchronization. This risk appears more pronounced in patients with even moderate left ventricular dysfunction and generally occurs after at least 1 year of pacing. As right ventricular apical pacing may be associated with the development of organic mitral insufficiency, other sites that allow for more physiological stimulation, such as right ventricular outflow tract septal pacing, have been developed, with good feasibility and reproducibility. However, the prospective randomized studi…
Mechanical circulatory support. An expert opinion of the Association of Intensive Cardiac Care and the Association of Cardiovascular Interventions of…
2021
Mechanical circulatory support (MCS) methods are used in patients with both acute and chronic heart failure, who have exhausted other options for pharmacological or surgical treatments. The purpose of their use is to support, partially or completely, the failed ventricles and ensure adequate organ perfusion, which allows patients to restore full cardiovascular capacity, prolonging their life and effectively improving its quality. The three most popular devices include an intra-aortic balloon pump (IABP), percutaneous assist devices (including Impella, TandemHeart), and venoarterial extracorporeal membrane oxygenation (VA-ECMO). A multidisciplinary approach with the special participation of …
Interventional femoral “crossover” bypass for peripheral ischaemia under cardiocirculatory support with the Impella CP heart pump
2020
Alternative methods of mechanical Cardiopulmonary Resuscitation
2000
Due to the relative ineffectiveness of standard resuscitation techniques, alternative methods have been explored for many years. The aim of new methods is to improve haemodynamics and increase survival rates. In spite of some encouraging haemodynamic results, all but one study failed to show an increase in long-term survival rates with an alternative method in a convincingly large group of patients (hospital discharge without neurological damage, and 1-year survival). In this study active compression-decompression resuscitation (ACD-CPR) increased long-term survival compared to standard-CPR. The results from certain individual studies, which showed a significant increase in short-term survi…
Infectious complications associated with short-term mechanical circulatory support in urgent heart transplant candidates
2021
[Abstract] Introduction and objectives. Short-term mechanical circulatory support is frequently used as a bridge to heart transplant in Spain. The epidemiology and prognostic impact of infectious complications in these patients are unknown. Methods. Systematic description of the epidemiology of infectious complications and analysis of their prognostic impact in a multicenter, retrospective registry of patients treated with short-term mechanical devices as a bridge to urgent heart transplant from 2010 to 2015 in 16 Spanish hospitals. Results. We studied 249 patients, of which 87 (34.9%) had a total of 102 infections. The most frequent site was the respiratory tract (n = 47; 46.1%). Microbiol…
What Is the Impact of Innovative Electronic Health Interventions in Improving Treatment Adherence in Asthma? The Pediatric Perspective
2019
Suboptimal adherence to treatment is a significant issue in the management of pediatric asthma and is a major cause of uncontrolled disease, life-threatening attacks, and increased utilization of healthcare resources. Electronic health (e-Health) solutions have the potential to positively impact asthma self-management in children and adolescents and their families, thereby improving treatment adherence and asthma outcomes. However, there is a lack of sufficient data to support widespread adoption of e-Health tools in pediatric asthma practice. A critical evaluation of the impact of these new interventions on treatment adherence in childhood asthma must consider unmet needs, heterogeneity of…
Chambered warm moist air eyelid warming devices – a review
2021
Background Eyelid warming is an important treatment for meibomian gland dysfunction (MGD). Specialized chambered devices, using warm moist air have been developed. Purpose To critically evaluate the literature on the safety and efficacy of chambered warm moist air devices in MGD treatment and pinpoint areas of future research. Methods PubMed and Embase were searched on 06 June 2021. The search term was ‘(warm OR heat OR steam OR goggle OR spectacle OR moist air) AND (meibomian OR MGD OR blepharitis OR eyelid OR dry eye OR DED)’. All relevant articles with available English full text were included. Results Eighteen articles assessing the application of chambered warm moist air eyelid warming…
Impella CP in cardiogenic shock due to acute myocardial infarction: From primary angioplasty to LIMA-LAD grafting.
2021
Shockwave intravascular lithoplasty for the treatment of calcified carotid artery stenosis: A very early single-center experience
2020
Endovascular treatment of calcified carotid disease represents one of the main challenges for the interventionalists. Plaque calcium load is one of the most important factors affecting the risk of procedural complications. A new tool called Shockwave intravascular lithotripsy (S-IVL; Shockwave Medical, Inc.) has been recently approved for the treatment of heavily calcified coronary and lower limb arteries but minimal data exist about the treatment of carotid arteries. We report our early experience of carotid stenting using S-IVL. We report two cases of symptomatic patients with severely calcified carotid artery diseases who were turned down for vascular surgeries. The first case was succes…