Search results for "DICS"
showing 10 items of 2714 documents
(i) Comminuted patellar fractures
2006
Summary Purpose of review This article reviews current best practice for the diagnosis and treatment of comminuted patellar fractures. Recent findings Patellar fractures make up about 1% of all fractures. As a rule, fractures of the patella are caused by direct trauma to the knee. A transverse fracture is the most common fracture type. Open reduction and internal fixation is the treatment of choice for the majority of displaced patellar fractures. Treatment must achieve anatomic reduction of the articular surface and reestablish the continuity of the extensor mechanism. Tension-band wiring, interfragmentary screw fixation and a combination of cerclage wiring and screw fixation are the most …
Breaststroke swimmer's knee
1980
The cause of the breaststroke swimmer's knee with medial pain of the knee joint has not been clearly identified. Breaststroke swimmers with knee pain were, therefore, examined arthros copically. None showed any other disorders of their knees than medial synovitis in seven of nine swimmers. Since structural abnormalities could be ruled out, biomechanical analyses utiliz ing cinematographic techniques were used to study patients swimming in a special flume with the speed set at 90% of their best competitive performance. The results indicate that the extension and flexion and also in some cases the hip abduction and adduction movements of the whip kick were performed with high peak angular ve…
Bindungsstudien mit Ulex Europaeus Agglutinin I (UEA-I) am Gefäßendothel der Synovialmembran*
2008
The lectin binding sites of the synovium of patients with rheumatoid arthritis and osteoarthritis were investigated. It was shown that Ulex europaeus agglutinin is a constant marker of the vascular endothelium and is not induced during the course of inflammatory process in rheumatoid arthritis.
Comparison between the directly measured achilles tendon force and the tendon force calculated from the ankle joint moment during vertical jumps.
1988
Summary The purpose of this study was to compare the relationship between the achilles tendon force and the tendon force estimated from the ankle joint moment (EATF) during vertical jump. A healthy male subject performed the following jumps on the force platform: (a) maximal vertical jump from a squat position without counter-movement; (b) maximal vertical jump from an erect standing position with a preliminary counter-movement; (c) repetitive submaximal hopping on the spot with preferred frequency. The achilles tendon force was measured directly with an implanted tendon transducer in all jumping conditions. In addition the joint moment obtained from the film and ground reaction force was u…
Profilin 1 Negatively Regulates Osteoclast Migration in Postnatal Skeletal Growth, Remodeling, and Homeostasis in Mice
2019
Profilin 1 (Pfn1), a regulator of actin polymerization, controls cell movement in a context-dependent manner. Pfn1 supports the locomotion of most adherent cells by assisting actin-filament elongation, as has been shown in skeletal progenitor cells in our previous study. However, because Pfn1 has also been known to inhibit migration of certain cells, including T cells, by suppressing branched-end elongation of actin filaments, we hypothesized that its roles in osteoclasts may be different from that of osteoblasts. By investigating the osteoclasts in culture, we first verified that Pfn1-knockdown (KD) enhances bone resorption in preosteoclastic RAW264.7 cells, despite having a comparable num…
Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept
2020
Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsi…
Range of Motion and Injury Occurrence in Elite Spanish Soccer Academies. Not Only a Hamstring Shortening-Related Problem.
2020
Sanz, A, Pablos, C, Ballester, R, Sanchez-Alarcos, JV, and Huertas, F. Range of motion and injury occurrence in elite Spanish soccer academies. Not only a hamstring shortening-related problem. J Strength Cond Res 34(7): 1924-1932, 2020-Age-related development of range of motion (ROM) during an active hip flexion (active straight leg raise) and its relationship with hamstring injury occurrence were examined in 1657 young male soccer players (9-18 years of age). Age-related differences in ROM showed a significant decrease from U9 to U11 (p = 0.001), from U11 to U13 (p0.005), and from U9 to U13 (p0.001), whereas ROM increased from U13 to U15 and from U13 to U18 (both p's0.001). Interestingly, …
Influence of sutures configuration on the strength of tendon-patch joints for rotator cuff tears treatment
2019
Abstract Purpose Massive rotator cuff tears are common in the aging population. The incidence of failed rotator cuff repairs is still quite high, especially in the treatment of full-thickness tears or revision repairs. In this context, natural and synthetic meshes can be used as augmentation scaffolds or as devices to close the gap between a retracted tendon and the bone. The purpose of this work is to evaluate the ultimate tensile strength of different tendon-patch joints in order to consider their use in the treatment of massive cuff tears. Materials and methods Porcine tendons and a synthetic low-density polypropylene mesh have been used. A preliminary study on the tensile strength of te…
Enhanced prolylhydroxylase activity in the posterior annulus fibrosus of canine intervertebral discs following long-term running exercise
2010
The effect of long-term excercise on the intervertebral disc collagen concentration (hydroxyproline), collagen-synthesizing enzymes (prolyl-4-hydroxylase, PH, and galactosyl-hydroxylysyl glucosyltransferase, GGT) and hydroxypyridinium crosslinks was studied in ten female beagle dogs. The dogs were run on a treadmill for 1 year starting at the age of 15 weeks. The daily running distance was gradually increased to 40km, which distance the dogs ran for the final 15 weeks. Ten untrained dogs from the same breeding colony served as controls. The nucleus pulposus and anterior and posterior halves of the annulus fibrosus of C2-3, T10-12, L4-5 disc segments were analysed. Crosslinks were measured f…
Biomechanical Analysis of a New Elbow Prosthesis
2019
Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model…