Critical issues in the PD testing methodology for XLPE-insulated MV cables: An experimental case
2017
This paper describes some critical issues arising during the partial discharge (PD) testing of a 500m delivery length of an XLPE-insulated MV cable. At first, conventional PD measurements were performed on the whole length by using a standard acquisition system; PDs activity was detected, but the system allowed the operator to localize the PDs only on a length of 70 m. A visual inspection of this section highlighted the presence of an excoriation in the outer sheet. Aiming at a more accurate pin-pointing of the defect, more measurements were carried out in the proximity of the outer defect using a portable PD detection system. These measurements showed PDs activity, whose source was located…
Controlled Cytotoxicity of Plasma Treated Water Formulated By Open-air Hybrid Mode Discharge
2017
Plasma‐activated liquids (PAL) attract increasing interest with demonstrated biological effects. Plasma exposure in air produces stable aqueous reactive species which can serve as chemical diagnostics of PAL systems. Here, we tailor aqueous reactive species inside plasma‐activated water (PAW) through treating water with AC air spark and glow discharges in contact with water. Chemical probing demonstrated species specificity between two types of PAW. Spark discharge PAW contains urn:x-wiley:14381656:media:ppap201600207:ppap201600207-math-0006 and urn:x-wiley:14381656:media:ppap201600207:ppap201600207-math-0007, while urn:x-wiley:14381656:media:ppap201600207:ppap201600207-math-0008and urn:x-w…
Investigation on partial discharges in HVDC cables after polarity reversal events
2020
Due to the accumulation of space charge inside the insulating layer of HVDC cables, the electric field under load conditions may be altered compared to what is established in HVAC cables. For example, a high thermal gradient leads to the inversion of the electric field pattern until the maximum value is reached in proximity of the dielectric-semicon interfaces. These maximum values can be further increased due to transient overvoltages and polarity reversal events until reaching electric field values higher than the rated ones. The main goal of this research is to investigate the possibility that, during these transient phenomena, conditions are created that favor the occurrence of partial …
Effect of Polarity Reversal on the Partial Discharge Phenomena
2020
In the field of High Voltage Direct Current (HVDC) transmission, the space charge accumulation phenomenon and the Partial Discharges (PD) phenomena are considered the main causes of dielectric ageing. During the years, the degradation effect of both phenomena under constant DC stress has been widely studied by several researchers. In case of polarity reversal, typically carried out to control bi-directional power flow between interconnected High Voltage transmission systems, the space charge movement may not synchronously follow the electric field polarity. This could make the moment of reversing polarity a very critical one, where space charge injected during preceding polarity produces hi…
Analytical solution for the diffusion of a capacitor discharge generated magnetic field pulse in a conductor
2016
Powerful forces arise when a pulse of a magnetic field in the order of a few tesla diffuses into a conductor. Such pulses are used in electromagnetic forming, impact welding of dissimilar materials and grain refinement of solidifying alloys. Strong magnetic field pulses are generated by the discharge current of a capacitor bank. We consider analytically the penetration of such pulse into a conducting half-space. Besides the exact solution we obtain two simple self-similar approximate solutions for two sequential stages of the initial transient. Furthermore, a general solution is provided for the external field given as a power series of time. Each term of this solution represents a self-sim…
The Effect of the Harmonic Content Generated by AC/DC Modular Multilevel Converters on HVDC Cable Systems
2019
With the increasing penetration of renewable and decentralized energy sources into the power grid, an extended use of DC voltages is expected on both distribution and transmission levels. Generation of DC voltages by means of voltage source converters is associated with a wide spectrum of harmonic distortions at converter terminals, both on the ac and on the dc sides. This can lead to partial discharges in power cables, which deteriorate insulation material thus weakening its performance and reducing cable life-time. In the previously published paper, the effect of harmonic distortion on appearance of partial discharges in cable insulation was evaluated. Here, the study related to the PD be…
A new technique for partial discharges measurement under DC periodic stress
2017
The aim of the present work is to recognize the type of defect in insulating materials employed in DC electrical systems. This analysis, under AC stress, is carried out by using the Phase Resolved method (PRPD). While, under constant voltage stress this method cannot be performed and measurements show complexities. In order to overcome these problems, a new technique is proposed, based on the application of a periodic continuous waveform. Simulation results, carried out by using a model based on a time-variable conductance of an air void defect, showed the PRPD pattern that can be obtain. Furthermore, compared to the constant DC stress, the measurement duration became lower and the discharg…
Estimating ion confinement times from beam current transients in conventional and charge breeder ECRIS
2019
International audience; Cumulative ion confinement times are probed by measuring decaying ion current transients in pulsed material injection mode. The method is applied in a charge breeder and conventional ECRIS yielding mutually corroborative results. The cumulative confinement time estimates vary from approximately 2 ms–60 ms with a clear dependence on the ion charge-to-mass ratio—higher charges having longer residence times. The long cumulative confinement times are proposed as a partial explanation to recently observed unexpectedly high ion temperatures. The results are relevant for rare ion beam (RIB) production as the confinement time and the lifetime of stable isotopes can be used f…
Exotic SiO(2)H(2) Isomers: Theory and Experiment Working in Harmony.
2016
Replacing carbon with silicon can result in dramatic and unanticipated changes in isomeric stability, as the well-studied CO2H2 and the essentially unknown SiO2H2 systems illustrate. Guided by coupled-cluster calculations, three SiO2H2 isomers have been detected and spectroscopically characterized in a molecular beam discharge source using rotational spectroscopy. The cis,trans conformer of dihydroxysilylene HOSiOH, the ground-state isomer, and the high-energy, metastable dioxasilirane c-H2SiO2 are abundantly produced in a dilute SiH4/O2 electrical discharge, enabling precise structural determinations of both by a combination of isotopic measurements and calculated vibrational corrections. …
Dimensionless Stage-Discharge Relationship for a Non-Linear Water Reservoir: Theory and Experiments
2020
In the field of hydrology, stage&ndash