Search results for "DM"
showing 10 items of 8932 documents
Diffusion-weighted MRI of the lung with hyperpolarized helium-3: A study of reproducibility
2005
Purpose To determine the reproducibility of several parameters of the ADC measurement by calculating the scan-to-scan intrasubject variability. Materials and Methods Measurements were performed using a gradient-echo sequence with a bipolar gradient for diffusion weighting (b = 3.89 sec/cm2). Five patients with pulmonary emphysema, and six healthy-lung volunteers were included in the study. Images were acquired after inspiration of 3He during a single inspiratory breath-hold. To assess the reproducibility, the measurement was performed twice (time between measurements = 20 minutes) without repositioning the subjects. Analysis was performed on the basis of region-of-interest (ROI) analysis an…
Immunonephelometric determination of the C4b-binding protein.
1993
A fully mechanised immunonephelometric method for the rapid and specific determination of C4b-binding protein (C4b-BP) in citrated plasma is described. The method utilizes commercially available rabbit antiserum against human C4b-BP and a nephelometer analyser. A single determination can be performed within 6 min, requiring 80 microliters sample volume. The measuring range is about 10 to 200% of normal C4b-BP. Precision is characterized by intraassay coefficients of variation between 1.5% and 2.8%, and interassay coefficients of variation between 4.0% and 4.6% for the same C4b-BP concentrations. The nephelometry of C4b-BP was correlated with electroimmunodiffusion (Laurell technique; r = 0.…
Comparison of the 45-Second/15-Second Intermittent Running Field Test and the Continuous Treadmill Test
2012
Purposes:To compare the physiological responses and maximal aerobic running velocity (MAV) during an incremental intermittent (45-s run/15-s rest) field test (45-15FIT) vs an incremental continuous treadmill test (TR) and to demonstrate that the MAV obtained during 45-15FIT (MAV45-15) was relevant to elicit a high percentage of maximal oxygen uptake (VO2max) during a 30-s/30-s intermittent training session.Methods:Oxygen uptake (VO2), heart rate (HR), and lactate concentration ([La]) were measured in 20 subjects during 2 maximal incremental tests and four 15-min intermittent tests. The time spent above 90% and 95% VO2max (t90% and t95% VO2max, respectively) was determined.Results:Maximal ph…
Dose escalation vs. continued doses of paroxetine and maprotiline: a prospective study in depressed out-patients with inadequate treatment response
1997
In view of the fact that controlled prospective studies on the benefits of dose escalation of the selective serotonin re-uptake inhibitor (SSRI) paroxetine are lacking, we conducted a double-blind, randomized, parallel-group multicentre study designed to compare the possible benefits of dose escalation of paroxetine and maprotiline in patients suffering from major or minor depression according to modified Research Diagnostic Criteria (RDC) with inadequate treatment response. The study sample consisted of 544 out-patients with different degrees of severity of depression. Patients received either 20 mg paroxetine (n = 271) or 100 mg maprotiline (n = 273) for the first 3 weeks in a double-blin…
Chronology of panic and avoidance, age of onset in panic disorder, and prediction of treatment response. A report from the Cross-National Collaborati…
1991
The relevance of the chronology between panic disorder and avoidance behavior and of an early, medium or late onset of panic disorder was tested. Groups from the sample of the cross-national collaborative panic study (CNCPS) were compared for differences in basic characteristics and for the ability to predict treatment response. Patients who developed avoidance behavior before the full syndrome of panic disorder had less often a full agoraphobia but were not different in their response to treatment. Patients with an early onset of panic disorder suffered more often from agoraphobia. The treatment response was similar in the groups with early, medium or late onset of panic disorder. Neither …
Lorcainide; II. Plasma concentration-effect relationship
1979
The effect of pre-stretch on mechanical efficiency of human skeletal muscle
1987
The mechanical efficiency of positive work was studied in six subjects performing three different types of exercises. On the first occasion the subjects ran on a motor-driven treadmill at 3.33 m s-1; the second and the third exercises consisted of performing rhythmical vertical jumps for 1 min both in rebound (RJ) and no-rebound (NRJ) conditions. The mechanical efficiency calculated in NRJ, which reflects only the conversion of biochemical energy into mechanical work, was found to be lower than the corresponding observation in RJ, 17.2 vs. 27.8% (P less than 0.001), respectively. These differences could not be explained by only the storage and recoil of elastic energy occurring in RJ compar…
Acute effects of an exposure to 100 ppm 1-methoxypropanol-2 on the upper airways of human subjects.
2013
Abstract The German MAK value of 1-methoxypropanol-2 has been fixed at 100 ppm. The aim of this study was to evaluate possible acute effects of an exposure to 100 ppm 1-methoxypropanol-2 on the upper airways of human subjects. Twenty subjects were exposed in a crossover design to 100 ppm 1-methoxypropanol-2 and to air in an exposure chamber for 4 h. Subjective symptoms were assessed by questionnaire. Olfactory thresholds for n-butanol and mucociliary transport time were measured before and after exposure. Concentrations of interleukin 1β and interleukin 8 were determined in nasal secretions taken after exposure. mRNA levels of interleukins 1β, 6 and 8, tumor necrosis factor α, granulocyte-m…
Dipole Source Analyses of Early Median Nerve SEP Components Obtained From Subdural Grid Recordings
2010
The median nerve N20 and P22 SEP components constitute the initial response of the primary somatosensory cortex to somatosensory stimulation of the upper extremity. Knowledge of the underlying generators is important both for basic understanding of the initial sequence of cortical activation and to identify landmarks for eloquent areas to spare in resection planning of cortex in epilepsy surgery. We now set out to localize the N20 and P22 using subdural grid recording with special emphasis on the question of the origin of P22: Brodmann area 4 versus area 1. Electroencephalographic dipole source analysis of the N20 and P22 responses obtained from subdural grids over the primary somatosensor…
Cross validation of the 1-mile walking test for men with mental retardation.
1997
The purpose of this study was to cross validate the equation developed by Rintala et al. (1992) to estimate the cardiorespiratory efficiency of men with mental retardation (MR). Subjects were 19 healthy men (27 ± 8 yr) with MR (IQ = 58 ± 12). Following familiarization, a graded maximal treadmill test and two 1-mile walk tests (Rockport Fitness Walking Test, RFWT) were administered. The peak VO 2 value was the criterion measure used to cross validate the equation. The equation was: Peak VO 2 (ml.kg -1 .min -1 ) = 101.92 - 2.356 (MILE) -0.420 (WEIGHT). The mean differences were 2.04 (MILE 1 )(P = 0.02) and 2.43 (MILE 2 )(P = 0.004) ml.kg -1 .min -1 . A significant positive correlation was fou…