Search results for "DOPPLER"

showing 10 items of 637 documents

Book review: New trends in cerebral homodynamics and neurosonology

1998

No abstract available

Settore MED/27 - NeurochirurgiaCerebral hemodynamics Transcranil doppler
researchProduct

SCROTO ACUTO: DIAGNOSI DIFFERENZIALE DI UN'EMERGENZA MEDICO-CHIRURGICA NELL'IMAGING ECOGRAFICO

2018

nd

Settore MED/36 - Diagnostica Per Immagini E RadioterapiaUltrasound Testis Color Doppler
researchProduct

Confronto tra aterosclerosi coronarica mediante CardioTC e aterosclerosi carotidea mediante ecocolorDoppler

2014

Settore MED/36 - Diagnostica Per Immagini E Radioterapiaaterosclerosi CardioTC ecocolorDoppler
researchProduct

Surface sediment dynamics along the Tunisian coast at Skhira (Gulf of Gabès, south-eastern Tunisia)

2015

Abstract An investigation was conducted in the summer of 2012 at 24 study stations along the Tunisian coast near Skhira (south-eastern Mediterranean Sea) through high resolution of analyses, grain size and mineral composition of surface sediment. An Acoustic Doppler Current Profiler showed Skhira's main coastal current to follow a direction 60°E, with its main axis south-west/north-east parallel to the coastline and its minor axis east-west. Current speeds were approximately 13 cm s−1 and 4.5 cm s−1 for the major and minor axes, respectively. Parallel to the coast, currents were generally mild to moderate, but often exceeded 20 cm s−1. An Argonaut meter recorded the dominant current directi…

Shoregeographygeography.geographical_feature_categorySedimentGeologySwellCurrent (stream)Longshore driftMediterranean seaOceanographyAcoustic Doppler current profilerGeologyRip currentEarth-Surface ProcessesJournal of African Earth Sciences
researchProduct

Spectral estimators for Doppler analysis of intracoronary ultrasound catheters

2002

With the zero-cross-detection method (ZCD) it has been shown that it is not possible to achieve a reproducible quantitative, and robust evaluation of an inter-coronary audio signal. The authors define spectral estimators to analyze the Doppler-audio signal. Measurements in a blood flow model have shown that the ZCD method underestimates the expected velocity at all speeds. Spectral analysis allows the determination of the actual and peak velocity more robustly and precisely. >

Signal processingsymbols.namesakeAudio signalPeak velocityComputer scienceRobustness (computer science)AcousticssymbolsEstimatorSpectral analysisBlood flowDoppler effect[1991] Proceedings Computers in Cardiology
researchProduct

On the Consistency of Non-Stationary Multipath Fading Channels with Respect to the Average Doppler Shift and the Doppler Spread

2017

This paper is concerned with the consistency of non-stationary multipath fading channels. We introduce conditions under which a channel model is consistent w.r.t. the average Doppler shift and the Doppler spread. The conditions are applied to two classes of non-stationary channel models. The first class, which is termed Class A, is characterized by channel models based on an integral relationship between the path phases and the associated time-variant Doppler frequencies. The second class of models, called the Class B models, emerges from standard sum-of-cisoids (SOC) models by replacing the time-independent Doppler frequencies by time-dependent Doppler frequencies. It is shown that the Cla…

SoundnessClass (set theory)05 social sciences050801 communication & media studies020206 networking & telecommunications02 engineering and technologyFirst classsymbols.namesake0508 media and communicationsConsistency (statistics)Path (graph theory)Statistics0202 electrical engineering electronic engineering information engineeringsymbolsFadingAlgorithmDoppler effectMultipath propagationMathematics
researchProduct

INTEGRAL and RXTE observations of accreting millisecond pulsar IGR J00291+5934 in outburst

2005

Simultaneous observations of the accretion-powered millisecond pulsar IGR J00291+5934 by International Gamma-Ray Astrophysics Laboratory and Rossi X-ray Timing Explorer during the 2004 December outburst are analysed. The average spectrum is well described by thermal Comptonization with an electron temperature of 50 keV and Thomson optical depth tau_T ~ 1 in a slab geometry. The spectral shape is almost constant during the outburst. We detect a spin-up of the pulsar with nudot=8.4x10E-13 Hz/s. The ISGRI data reveal the pulsation of X-rays at a period of 1.67 milliseconds up to ~150 keV. The pulsed fraction is shown to increase from 6 per cent at 6 keV to 12--20 per cent at 100 keV. This is n…

Spectral shape analysisAstrophysics::High Energy Astrophysical PhenomenaFOS: Physical sciencesHot spot (veterinary medicine)Astrophysicsaccretion accretion discs binaries: close stars: individual: IGR J00291+5934 stars: neutron X-rays: binariesAstrophysics01 natural sciences7. Clean energy[PHYS.ASTR.CO]Physics [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]symbols.namesakestars: neutronPulsaraccretionMillisecond pulsar0103 physical sciencesOptical depth (astrophysics)010306 general physics010303 astronomy & astrophysicsPhysicsMillisecondbinaries: close[SDU.ASTR]Sciences of the Universe [physics]/Astrophysics [astro-ph]Astrophysics (astro-ph)Astronomy and Astrophysicsaccretion discspulsars: individual (IGR J00291+5934)13. Climate actionSpace and Planetary SciencesymbolsElectron temperatureDoppler effectX-ray: binaries
researchProduct

US-Elastography for Breast Lesion Characterization: Prospective Comparison of US BIRADS, Strain Elastography and Shear wave Elastography

2020

 To evaluate the diagnostic performance of strain elastography (SE) and 2 D shear wave elastography (SWE) and SE/SWE combination in comparison with conventional multiparametric ultrasound (US) with respect to improving BI-RADS classification results and differentiating benign and malignant breast lesions using a qualitative and quantitative assessment. In this prospective study, 130 histologically proven breast masses were evaluated with baseline US, color Doppler ultrasound (CDUS), SE and SWE (Toshiba Aplio 500 with a 7-15 MHz wide-band linear transducer). Each lesion was classified according to the BIRADS lexicon by evaluating the size, the B-mode and color Doppler features, the SE qualit…

Strain elastographybreast lesions; characterization; shear wave elastography; strain elastography; BIRADSTransducersBreast lesionBreast NeoplasmsPhysical examinationbreast lesionsSensitivity and Specificity030218 nuclear medicine & medical imagingDiagnosis Differential03 medical and health sciences0302 clinical medicineQuantitative assessmentHumansMedicinecharacterizationRadiology Nuclear Medicine and imagingBreastProspective StudiesUltrasonographyshear wave elastographyShear wave elastography030219 obstetrics & reproductive medicinemedicine.diagnostic_testbusiness.industryUltrasoundReproducibility of ResultsColor doppler ultrasoundBIRADSstrain elastographyElasticity Imaging TechniquesFemaleUltrasonography MammaryElastographybusinessNuclear medicineUltraschall in der Medizin - European Journal of Ultrasound
researchProduct

Use of middle cerebral velocity and blood pressure for the analysis of cerebral autoregulation at various frequencies: The coherence index

1998

A common component in many protocols for the evaluation of cerebral autoregulation is the comparison of transcranial Doppler ultrasound (TCD) velocities with blood pressure recordings, in which correlations between these two signals correspond to impaired autoregulation. With long data sets and complicated paradigms, however, visual inspection alone cannot adequately distinguish random coincidence from consistent correlation in a statistically valid fashion. We suggest and illustrate the use of the coherence index for this purpose. To illustrate this technique, long-term recordings of TCD velocity and blood pressure were obtained from 6 normal subjects and using 23 data segments from 8 pati…

Subarachnoid hemorrhageUltrasonography Doppler TranscranialHemodynamicsBlood PressureCerebral autoregulationCorrelationNuclear magnetic resonanceReference ValuesmedicineTidal VolumeHomeostasisHumansAutoregulationTranscranial doppler cerebral autoregulationMathematicsFourier AnalysisSettore MED/27 - NeurochirurgiaGeneral MedicineCoherence (statistics)Cerebral ArteriesSubarachnoid Hemorrhagemedicine.diseaseTranscranial DopplerPlethysmographyBlood pressureNeurologyAnesthesiaNeurology (clinical)Blood Flow VelocitySoftware
researchProduct

Spectral broadening by spatial effects in X-ray microcalorimeters with superconducting absorber and NTD-Ge thermal sensor

2004

We discuss how the sensitivity to the position of absorption of the photons can affect the spectral resolution of X-ray microcalorimeters with superconducting Sn absorber and NTD-Ge thermal sensor. Data obtained through the computer simulations are reported for microcalorimeters with different geometries and phonon transmission probabilities at the interface between the absorber and thermistor.

SuperconductivityPhysicsNuclear and High Energy PhysicsPhotonPhysics::Instrumentation and DetectorsPhononbusiness.industryThermistorX-rayNumerical simulationOpticsMicrocalorimeterX-ray spectroscopySpectral resolutionbusinessAbsorption (electromagnetic radiation)InstrumentationDoppler broadeningNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct