A Monte Carlo investigation of the dosimetric characteristics of the CSM11 137Cs source from CIS

2000

The purpose of this study is to calculate basic dosimetry data for a CSM11 low dose rate 137Cs source in water. This source is widely used in afterloadable dome cylinders designed to homogeneously irradiate the vaginal cuff alone or additional areas of the vagina in hysterectomized patients. In this study, the Monte Carlo simulation code GEANT, incorporating in detail source geometry, is used to investigate the dosimetric characteristics of the source. The calculated data were analyzed using a fitting procedure that is described in detail. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian lookup tables (classically al…

Physicsbusiness.industryAirRadiotherapy Planning Computer-AssistedAttenuationmedicine.medical_treatmentMonte Carlo methodBrachytherapyIsotropyWaterGeneral MedicineSievert integralComputational physicsCesium RadioisotopesLookup tablemedicineHumansDosimetryRadiometryAnisotropyNuclear medicinebusinessMonte Carlo MethodMedical Physics
researchProduct

Dosimetric characteristics of the CDC-type miniature cylindrical 137Cs brachytherapy sources

2002

The low dose rate CDC-type miniature cylindrical 137 Cs sources are available, with one or three active beads, for use in source trains in automatic and manual afterloading systems for gynecological brachytherapy. Absolute dose rate distributions in water have been calculated around these sources using the Monte CarloGEANT3 code and they are presented as conventional two-dimensional Cartesian lookup tables. The AAPM Task Group 43 formalism for dose calculation has been also applied. The dose rate constant obtained for the one bead source is Λ=1.113±0.003 cGyh −1 U −1 , and the value for the three bead source is Λ=1.103±0.003 cGyh −1 U −1 . Finally, for the treatment planning systems based o…

Physicsbusiness.industryAirRadiotherapy Planning Computer-Assistedmedicine.medical_treatmentAttenuationBrachytherapyMonte Carlo methodBrachytherapyGeneral MedicineComputational physicslaw.inventionlawLookup tablemedicineDosimetryCartesian coordinate systemRadiometryRadiation treatment planningDose rateNuclear medicinebusinessMonte Carlo MethodAlgorithmsMedical Physics
researchProduct

Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: evaluation of applicator attenuation and superposition approximation effe…

2004

The purpose of this study is to calculate the dose rate distribution for the Amersham Cs-137 pellet source used in brachytherapy with the Selectron low-dose-rate remote afterloading system in gynaecological applications using the Monte Carlo code GEANT4. The absolute dose rate distribution for the pellet source was obtained and presented as a one-dimensional absolute dose rate table as well as in the Task Group 43 dose-calculation formalism. In this study, excellent agreement was found between the point source theoretical model using fitted polynomial values and Monte Carlo calculations of the dose rate distribution for the pellet source. A comparison study was also made between the dose ra…

Physicsbusiness.industryPoint sourcemedicine.medical_treatmentAttenuationRadiotherapy Planning Computer-AssistedPhysics::Medical PhysicsMonte Carlo methodBrachytherapyBrachytherapyGeneral MedicineComputational physicsSelectron tubeSuperposition principleCesium RadioisotopesmedicineDosimetryPolar coordinate systemNuclear medicinebusinessRadiometryMonte Carlo MethodSoftwareMedical physics
researchProduct

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

2015

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit …

Physicsbusiness.industrymedicine.medical_treatmentBrachytherapyGeneral MedicineCollimated lightKermaOpticsAbsorbed doseIonizationIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct

SU-GG-T-70: A Dosimetric Study of the MicroSelectron HDR Ir-192 Brachytherapy Source

2010

Purpose: Recently the manufacturer of the mHDR‐v2 HDR Ir‐192 brachytherapy source clarified design changes that may alter the existing dosimetric data for this source. The object of this study was to obtain new dose rate tables following the TG‐43 formalism and to provide these data in close proximity to the source with high spatial resolution including the electron dosimetric contributions from Ir‐192 disintegration. Methods and Material: To study the source we used three different Monte Carlo codes: MCNP5, GEANT4, and Penelope. The source was located inside a 40 cm radius water phantom. Dose and kerma were obtained using 0.1 mm thick voxels to provide high‐resolution dosimetry near the so…

Physicsbusiness.industrymedicine.medical_treatmentBrachytherapyMonte Carlo methodGeneral MedicineBrachytherapy sourceImaging phantomComputational physicsKermamedicineHigh spatial resolutionDosimetryNuclear medicinebusinessImage resolutionMedical Physics
researchProduct

SU-E-T-508: Monte Carlo Dosimetric Study of the CSM40 Low Dose Rate Source

2013

Purpose: There is a LDR 137Cs brachytherapy source, CSM40, developed by Eckert & Ziegler BEBIG. Fundamental dosimetric datasets to be used on treatment planning systems do not exist for this source. This study aims to obtain quality dosimetric data for this source for its use in clinical practice as required by AAPM and ESTRO. Methods: Penelope2008 and GEANT4 Monte Carlo codes were used to characterize this source dosimetry. Water composition and mass density was that recommended by AAPM. Due to the typical energies of the 137 Cs, dose for small distances can be approximated by collisional kerma. Therefore, we have considered collisional kerma for r<20 cm. To provide adequate spatial resolu…

Physicsbusiness.industrymedicine.medical_treatmentBrachytherapyMonte Carlo methodGeneral MedicineComputational physicsWater compositionKermamedicineDosimetryLow dose rateDose rateNuclear medicinebusinessImage resolutionMedical Physics
researchProduct

Dosimetry revisited for the HDR I192r brachytherapy source model mHDR-v2

2010

Purpose: Recently, the manufacturer of the HDR I 192 r mHDR-v2 brachytherapysource reported small design changes (referred to herein as mHDR-v2r) that are within the manufacturing tolerances but may alter the existing dosimetric data for this source. This study aimed to (1) check whether these changes affect the existing dosimetric data published for this source; (2) obtain new dosimetric data in close proximity to the source, including the contributions from I 192 r electrons and considering the absence of electronic equilibrium; and (3) obtain scatterdose components for collapsed cone treatment planning system implementation. Methods: Three different Monte Carlo(MC) radiation transport co…

Physicsbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineRadiusImaging phantomComputational physicsKermaAbsorbed dosemedicineDosimetryNuclear medicinebusinessRadiation treatment planningMedical Physics
researchProduct

SU-E-T-509: DICOM Test Case Plans for Model-Based Dose Calculations Methods in Brachytherapy

2013

Purpose: The TG‐186 report provides guidance to early adopters of model‐based dose calculation algorithms (MBDCAs) for brachytherapy. A charge of the AAPM‐ESTRO Working Group on MBDCA is to develop well‐defined test case plans, available as references for the software commissioning process to be performed by end‐users. The aim of this work is to develop test case plans for a generic HDR 192 Ir source alone and in combination with a vaginal cylinder applicator with 180° tungsten‐alloy shielding in a DICOM‐based water phantom. Methods: A DICOM CT dataset was created with a 30 cm diameter water sphere surrounded by air. The voxel size was 1.33×1.33×1.33 mm3 for evaluating absorbed dose rate (c…

Physicsbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral Medicinecomputer.software_genreImaging phantomDICOMVoxelConsistency (statistics)medicineComputational statisticsDosimetryNuclear medicinebusinesscomputerMedical Physics
researchProduct

Response to “Comment on ‘Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brac…

2016

Physicsbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyThermal ionizationGeneral Medicine030218 nuclear medicine & medical imagingComputational physics03 medical and health sciences0302 clinical medicineLow energy030220 oncology & carcinogenesisIonizationCalibrationmedicineMeasurement uncertaintyDosimetryNuclear medicinebusinessMedical Physics
researchProduct

An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributio…

2009

Certain brachytherapy dose distributions, such as those for LDR prostate implants, are readily modeled by treatment planning systems (TPS) that use the superposition principle of individual seed dose distributions to calculate the total dose distribution. However, dose distributions for brachytherapy treatments using high-Z shields or having significant material heterogeneities are not currently well modeled using conventional TPS. The purpose of this study is to establish a new treatment planning technique (Tufts technique) that could be applied in some clinical situations where the conventional approach is not acceptable and dose distributions present cylindrical symmetry. Dose distributi…

Physicsbusiness.industrymedicine.medical_treatmentMonte Carlo methodCoordinate systemBrachytherapyGeneral MedicineData setPlanned DosemedicineDosimetryNuclear medicinebusinessRadiation treatment planningImage resolutionMedical Physics