Search results for "DOSIMETRY"

showing 10 items of 297 documents

MO-D-AUD B-08: Treatment Planning for Complex Brachytherapy Dose Distributions Using High-Z Shields and Conventional Software

2008

Purpose: Certain brachytherapydose distributions, like for LDR prostate implants, are readily modeled by treatment planningsoftware using the superposition principle of individual seeds to replicate the total dose distribution. However, dose distributions for brachytherapy treatments using high‐Z shields are currently not well‐modeled using conventional software.Method and Materials:Dose distributions from complex brachytherapy plaques determined using Monte Carlo methods were used as input data, and included COMS‐based eye plaques using 125 I , 103 Pd , and 131 Cs ; 4–8cm diameter AccuBoost peripheral breast brachytherapy applicators from Advanced Radiation Therapy; and the 2 and 3cm diame…

Physicsbusiness.industrymedicine.medical_treatmentMonte Carlo methodCoordinate systemBrachytherapyGeneral MedicineDistribution (mathematics)Planned DosemedicineDosimetryRadiation treatment planningNuclear medicinebusinessImage resolutionMedical Physics
researchProduct

Dosimetric study of the 15mm ROPES eye plaque

2004

The main aim of this paper is to make a study of dose-rate distributions obtained around the 15 mm, radiation oncology physics and engineering services, Australia (ROPES) eye plaque loaded with {sup 125}I model 6711 radioactive seeds. In this study, we have carried out a comparison of the dose-rate distributions obtained by the algorithm used by the Plaque Simulator (PS) (BEBIG GmbH, Berlin, Germany) treatment planning system with those obtained by means of the Monte Carlo method for the ROPES eye plaque. A simple method to obtain the dose-rate distributions in a treatment planning system via the superposition of the dose-rate distributions of a seed placed in the eye plaque has been develo…

Physicsgenetic structuresBackscatterbusiness.industryAttenuationmedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomScleraSuperposition principlemedicine.anatomical_structureOpticsmedicineDosimetryNuclear medicinebusinessMedical Physics
researchProduct

Technical note: Monte Carlo derivation of TG-43 dosimetric parameters for radiation therapy resources and 3M Cs-137 sources

2005

In clinical brachytherapy dosimetry, a detailed dose rate distribution of the radioactive source in water is needed in order to plan for quality treatment. Two Cs-137 sources are considered in this study; the Radiation Therapy Resources 67-800 source (Radiation Therapy Resources Inc., Valencia, CA) and the 3M model 6500/6D6C source. A complete dosimetric dataset for both sources has been obtained by means of the Monte Carlo GEANT4 code. Dose rate distributions are presented in two different ways; following the TG43 formalism and in a 2D rectangular dose rate table. This 2D dose rate table is helpful for the TPS quality control and is fully consistent with the TG43 dose calculation formalism…

Physicsmedicine.medical_specialtyPhotonbusiness.industrymedicine.medical_treatmentRadioactive sourceBrachytherapyMonte Carlo methodGeneral MedicineComputational physicsRadiation therapymedicineRelative biological effectivenessDosimetryMedical physicsbusinessQuality assuranceMedical Physics
researchProduct

A mammographic phantom image reconstruction through Monte Carlo techniques

2005

Mammographic phantoms are employed during quality control test in breast screening locations and other health centres. These quality controls are performed to achieve the image quality required to detect breast abnormalities, ensuring the minimum risk to radiographied women. The aim of this study is the development of a methodology to reproduce the image of a mammogram during a routine exposure in a breast screening programme. In a first step, the CIRS 11A (MAMMO PHANTOM SP01) mammographic phantom has been simplified and modelled with the Monte Carlo transport code MCNP-4c2. Different tallies (F2 and F5) have been used to score the photon flux under the phantom, and a group of aluminium lay…

Physicsmedicine.medical_specialtyPixelmedicine.diagnostic_testbusiness.industryImage qualityMonte Carlo methodIterative reconstructionImaging phantomKermamedicineDosimetryMammographyComputer visionMedical physicsArtificial intelligencebusiness
researchProduct

A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests.

2012

In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can …

Physicsmedicine.medical_specialtyRadiological and Ultrasound TechnologyPixelbusiness.industryDetectorRadiosurgerySquare (algebra)OpticsIonizationIonization chambermedicineDosimetryAnisotropyHumansRadiology Nuclear Medicine and imagingMedical physicsRadiotherapy Intensity-ModulatedAnisotropybusinessRadiometryDiodePhysics in medicine and biology
researchProduct

SU-FF-T-14: Monte Carlo Derivation of TG-43 Dosimetric Parameters for Radiation Therapy Resources and 3M Cs-137 Sources

2005

Purpose: In clinical brachytherapydosimetry a detailed dose rate distribution of the radioactive source in water is needed to make a quality treatment planning. Two Cs‐137 sources are considered in this study the Radiation Therapy Resources 67–800 source(Radiation Therapy Resources Inc., Valencia, CA) and the 3M model 6500/6D6C source.Material and methods: A complete dosimetric dataset for both sources has been obtained by means of the Monte Carlo GEANT4 code. Results:Dose rate distributions are presented in two different ways, following the TG43 formalism and in a 2D rectangular dose rate table. Conclusion: This 2D dose rate table is helpful for the TPS quality control and it is fully cons…

Physicsmedicine.medical_specialtybusiness.industryRadioactive sourcemedicine.medical_treatmentBrachytherapyMonte Carlo methodGeneral MedicineComputational physicsRadiation therapymedicineDosimetryMedical physicsbusinessAnisotropyRadiation treatment planningQuality assuranceMedical Physics
researchProduct

Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus 192Ir sources.

2001

In this study a complete set of dosimetric data for the GammaMed high dose rate (HDR) 12i and Plus 192 Ir sources are presented. These data have been calculated by means of the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water are presented as conventional two dimensional (2D) Cartesian look-up tables, and in the TG43 formalism.

Physicsmedicine.medical_treatmentBrachytherapyMonte Carlo methodBrachytherapyBiophysicsWaterTechnical noteGeneral MedicineIridium RadioisotopesBiophysical PhenomenaComputational physicslaw.inventionFormalism (philosophy of mathematics)lawmedicineEconometricsDosimetryAnisotropyCartesian coordinate systemDose rateRadiometryMonte Carlo MethodMedical physics
researchProduct

Use of 70 MeV proton beam for medical applications at INFN-LNS: CATANA project

2000

The project CATANA (Centro di Adro Terapia ed Applicazioni Nucleari Avanzate) is a collaboration between the INFN-Laboratori Nazionali del Sud (LNS), Physics Department, Ophthalmology Institute and Radiology Institute of the Catania University and CSFNSM Catania. The main goal of CATANA is the study and the application of protontherapy for the treatment of shallow tumors (4 cm max) like uveal melanomas and subfoveal macular degenerations.

Proton computed tomographymedicine.medical_specialtybusiness.industryMedicinePatient treatmentMedical physicsbusinessNuclear medicineNeutron dosimetryAIP Conference Proceedings
researchProduct

QA of dynamic MLC based on EPID portal dosimetry.

2010

Abstract Purpose Dynamic delivery of intensity modulated beams (dIMRT) requires not only accurate verification of leaf positioning but also a control on the speed of motion. The latter is a parameter that has a major impact on the dose delivered to the patient. Time consumed in quality assurance (QA) procedures is an issue of relevance in any radiotherapy department. Electronic portal imaging dosimetry (EPID) can be very efficient for routine tests. The purpose of this work is to investigate the ability of our EPID for detecting small errors in leaf positioning, and to present our daily QA procedures for dIMRT based on EPID. Methods and materials A Varian 2100 CD Clinac equipped with an 80 …

Quality ControlReproducibilityComputer sciencebusiness.industryElectrical Equipment and SuppliesSmall deviationsEpid dosimetryBiophysicsGeneral Physics and AstronomyGeneral MedicineLinear particle acceleratorPortal imagingGap widthDosimetryRadiology Nuclear Medicine and imagingbusinessRadiometryQuality assuranceSimulationBiomedical engineeringPhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
researchProduct

Evaluation of DR and CR digital mammography systems based on phantom and breast dosimetry.

2006

Digital mammography has been progressively introduced in screening centers, since recent evolution of CR and DR detectors. However, it is questionable which exposure conditions would be more suitable when these techniques are applied, in order to reduce the glandular breast doses, as they are related with induced carcinogenesis. Several exposures have been performed in CR and DR mammography units for comparing absorbed doses during quality control assessments and during screening, diagnosis and treatment. In the first case, the CIRS11A mammographic phantom has been used with standard exposure conditions (28 kV, AEC mode with blackening +0, 50:50 glandularity and 4.5 compressed breast thickn…

Quality Controlmedicine.medical_specialtyDigital mammographyImage qualityBreast NeoplasmsRadiation DosageImaging phantommedicineMammographyDosimetryHumansMedical physicsRadiometrymedicine.diagnostic_testbusiness.industryComputersPhantoms ImagingEquipment DesignRadiographic Image EnhancementClinical diagnosisReference valuesRadiographic Image EnhancementFemaleNuclear medicinebusinessSoftwareMammographyConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
researchProduct