Fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism

2001

The purpose of this study is to find fitted functional forms to the anisotropy function, F(r,θ), and the radial dose function, g(r), in order to characterize dose-rate distributions around all the high-intensity 192 Ir sources currently in use. Dosimetry data are at present available as tables for: the microSelectron HDR (“classic” and “new” design models), the PDR source, and the VariSource HDR source, expressed in terms of the AAPM Task Group No. 43 recommendations. There is only one paper out which introduces a functional form to fit the anisotropy function, but only for symmetric sources with respect to the transverse axis. However, dosimetric data of the HDR and PDR sources mentioned a…

RadioisotopesTask groupModels Statisticalmedicine.medical_treatmentBrachytherapyMathematical analysisTransverse axisGeneral MedicineModels TheoreticalIridiumFormalism (philosophy of mathematics)medicineAnisotropyDosimetryRadiometryDose rateAnisotropyMonte Carlo MethodAlgorithmMathematicsMedical Physics
researchProduct

End-to-end tests using alanine dosimetry in scanned proton beams

2018

This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis) phantoms were used for end-to-end tests at MedAustron. The phantoms were equipped with alanine detectors, radiochromic films and ionization chambers. The correction for the 'quenching' effect of alanine pellets was implemented in the Monte Carlo platform of the evaluation version of RayStation TPS. During the end-to-end tests, the phantoms were transferred through the workflow…

Radiology Nuclear Medicine and ImagingMaterials sciencePelviMonte Carlo methodanthropomorphic phantomauditRadiation DosageImaging phantom030218 nuclear medicine & medical imaginglaw.inventionPelvisSynchrotron03 medical and health sciences0302 clinical medicinelawIonizationend to end testDosimetryHumansPencil-beam scanningRadiometryAlaninedosimetryRadiological and Ultrasound TechnologyPhantoms ImagingRadiotherapy Planning Computer-Assistedequipment and suppliesSynchrotron030220 oncology & carcinogenesisIonization chamberProtonProtonsHeadMonte Carlo MethodBeam (structure)SynchrotronsBiomedical engineeringHuman
researchProduct

2017

In the context of radiopharmacy and molecular imaging, the concept of theranostics entails a therapy-accompanying diagnosis with the aim of a patient-specific treatment. Using the adequate diagnostic radiopharmaceutical, the disease and the state of the disease are verified for an individual patient. The other way around, it verifies that the radiopharmaceutical in hand represents a target-specific and selective molecule: the “best one” for that individual patient. Transforming diagnostic imaging into quantitative dosimetric information, the optimum radioactivity (expressed in maximum radiation dose to the target tissue and tolerable dose to healthy organs) of the adequate radiotherapeutica…

Radionuclidemedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentPharmaceutical ScienceNuclear dataContext (language use)010403 inorganic & nuclear chemistry01 natural sciences030218 nuclear medicine & medical imaging0104 chemical sciencesRadiation therapy03 medical and health sciences0302 clinical medicinePositron emission tomographyDrug DiscoverymedicineMedical imagingMolecular MedicineDosimetryMolecular imagingNuclear medicinebusinessPharmaceuticals
researchProduct

UV light energy storage and thermoluminescence in AlN ceramics

2007

AlN ceramics, untreated and subjected to oxygen ion implantation, are studied for potential application in TL dosimetry of UV light. Based on photoluminescence and thermoluminescence measurements there are shown advantages of the selection of the 480 emission band for TL signal recording instead of the previously used 400 nm band: higher intensity of the TL signal, lower fading rate of the accumulated TL signal, excitation region (270-340 nm) corresponding to UV-B range, monitoring of which is actual in UV dosimetry. (© 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

Range (particle radiation)Materials sciencePhotoluminescencebusiness.industryCondensed Matter PhysicsThermoluminescenceSignalvisual_artLight energyvisual_art.visual_art_mediumDosimetryOptoelectronicsCeramicbusinessExcitationphysica status solidi c
researchProduct

Study of intrinsic energy dependence of α-alanine and dose intercomparison with ESR and ISE techniques

1993

Abstract The intrinsic energy behavior of the radiation chemical yields G(R·) and G(NH3) which determine the dose response for the alanine/ESR and alanine/Ion-Selective Electrode (ISE) system, is an important characteristic for the consistent use in different radiation environments. Therefore, the response of ISS and Gent α-alanine dosimeters in the dose range 0.1 to 700 kGy was examined with 60Co, bremsstrahlung and electron beam radiation. Bremsstrahlung beams with end point energy between 5 and 12 MeV and electron beams with mean energy at the effective point of measurement between 4 and 25 MeV were used. Analysis of the 60Co calibration results shows that there are no significant differ…

Range (particle radiation)RadiationDosimeterChemistryCalibrationAnalytical chemistryElectron beam processingBremsstrahlungDosimetryElectronRadiationApplied Radiation and Isotopes
researchProduct

Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions

2013

Abstract The most popular types of LiF-based thermoluminescent (TL) detectors, LiF:Mg,Ti (MTS-N) and LiF:Mg,Cu,P (MCP-N), have been investigated, with respect to their dose (fluence) response and relative TL efficiency to different ion species. The detectors were irradiated using the nitrogen, iron, krypton and xenon ion beams, at energies ranging from 5.0 to 9.3 MeV/n. Supra- and sublinear response was found, for the MTS-N and MCP-N, respectively, similarly as observed for γ-rays. However, the level of nonlinearity of response of studied detectors is strongly reduced by increasing values of the ion ionization density (no supralinearity for Xe ions, for MTS-N, within calculated uncertaintie…

Range (particle radiation)Radiationdosimetryta114KryptonRadiochemistryAnalytical chemistryLithium fluoridechemistry.chemical_elementFluenceThermoluminescenceIonchemistry.chemical_compoundXenonchemistryIrradiationInstrumentationRadiation Measurements
researchProduct

Nuclear magnetic resonance relaxometry and imaging for dosimetry with agarose Fricke gel

2016

Relaxometrychemistry.chemical_compoundNuclear magnetic resonanceMaterials sciencechemistryBiophysicsGeneral Physics and AstronomyAgaroseDosimetryRadiology Nuclear Medicine and imagingGeneral MedicineFricke gelPhysica Medica
researchProduct

Response of GAFChromic® HD-V2 film dosimeter in 10-300 Gy dose range for radiation testing of electronic devices

2019

The study reported in this paper aimed to investigate the response of a GAFChromic? HD-V2 film dosimeter in the dose range between 10 and 300 Gy, normally used to perform irradiation tests on electronic devices with a 60Co gamma-ray irradiator. The well-defined linearity of response in terms of absorbance as a function of absorbed dose, easiness of handling and data analysis of irradiated dosimeters, reproducibility, stability, and insensitivity to visible light and most of the environmental parameters, make HD-V2 film a flexible, inexpensive and reliable dose measurement device. The study has shown a fogging effect of the dosimeter response since its value changes over time. Strategies and…

ReproducibilityRange (particle radiation)HD-V2 filmDosimeterMaterials scienceGafchromic dosimetryRadiation testingElectronic deviceNuclear Energy and EngineeringDoseGamma-ray irradiationAbsorbed doseCalibrationlcsh:QC770-798lcsh:Nuclear and particle physics. Atomic energy. RadioactivityIrradiationElectronicsSafety Risk Reliability and QualityBiomedical engineeringNuclear Technology and Radiation Protection
researchProduct

Supplement 2 for the 2004 update of the AAPM Task Group No. 43 Report: Joint recommendations by the AAPM and GEC-ESTRO

2017

Since publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG-43U1) and its 2007 supplement (TG-43U1S1), several new low-energy photon-emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical purposes and are posted on the Brachytherapy Seed Registry managed jointly by the AAPM and the Imaging and Radiation Oncology Core Houston Quality Assurance Center (IROC Houston). Given increasingly closer interactions among physicists in North America and Europe, the AAPM and the Groupe Europeen de Curietherapie-European Society for Radiotherapy & Oncology (GEC…

Research Reportmedicine.medical_specialtymedicine.medical_treatmentBrachytherapyBrachytherapy030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRadiation oncologymedicineHumansDosimetryMedical physicsRadiometryRadiation treatment planningRadiation oncologistPhotonsTask groupbusiness.industryRadiotherapy DosageGeneral MedicineEurope030220 oncology & carcinogenesisPatient dosebusinessMonte Carlo MethodQuality assuranceMedical Physics
researchProduct

Radioluminescence, thermoluminescence and dosimetric properties of ZnO ceramics

2017

The authors gratefully acknowledge the financial support for this work from research grant ERA.NET RUS Plus Nr.609556 and from the SFERA II project Transnational Access activities (EU 7th Framework Programme Grant Agreement no 312643) for supporting ZnO nanopowders preparation.

SCANNING ELECTRON MICROSCOPYMaterials scienceTHERMOLUMINESCENCEZINC OXIDEAnalytical chemistryMineralogySintering02 engineering and technologyC. THERMOSTIMULATED LUMINESCENCE01 natural sciencesThermoluminescenceTHERMOSTIMULATED LUMINESCENCESpectral lineD. DOSIMETRYDOSIMETRIC PROPERTIESB. SINTERINGSINTERING CONDITION0103 physical sciences:NATURAL SCIENCES:Physics [Research Subject Categories]Materials ChemistryCeramicIrradiation010302 applied physicsCERAMIC MATERIALSProcess Chemistry and TechnologyA. ZNO CERAMICRadioluminescenceAtmospheric temperature rangeDOSIMETRYZNO CERAMIC021001 nanoscience & nanotechnologySurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsIRRADIATIONRADIO-LUMINESCENCEDEFECT LUMINESCENCEvisual_artLUMINESCENCECeramics and Compositesvisual_art.visual_art_mediumSINTERINGTEMPERATURE RANGE0210 nano-technologyLuminescenceRADIOLUMINESCENCE SPECTRA
researchProduct